Part Number: LH1000I-373000
Category: Generator Replacement Parts & Fuel System Components
Type: Fuel Valve – Genuine OEM Replacement Fuel System Valve


The Homelite LH1000I-373000 Fuel Valve is a genuine OEM replacement fuel-system component designed for select Homelite digital inverter generators and compatible equipment applications.


Product Specifications

  • Part Number: LH1000I-373000
  • Manufacturer: Homelite
  • Product Type: Fuel Valve
  • OEM Description: Fuel Valve / Fuel Switch Assembly
  • Alternate Description: Fuel Switch / Fuel Shut-Off Valve / Generator Fuel Valve
  • Component Type: Fuel System / Fuel Control Component
  • Primary Application: Outdoor Power Equipment
  • Common Equipment Type: Digital Inverter Generators
  • System: Fuel Delivery System
  • Function: Controls Fuel Flow Through the Applicable Generator Fuel System
  • Installation Location: Fuel System – Model Dependent
  • Associated Components: Fuel Tank / Fuel Hose / Fuel Filter / Carburetor
  • Approximate Dimensions: 2.40 x 2.10 x 1.60 Inches
  • Replacement Type: Direct OEM Replacement
  • OEM Status: Genuine OEM Part
  • Condition: New
  • Quantity: 1 Fuel Valve
  • Part Number Reference: LH1000I-373000

Features & Benefits

  • Genuine OEM replacement fuel valve
  • Also identified in parts documentation as a Fuel Switch Assembly
  • Designed for compatible Homelite generator applications
  • Replaces the original equipment fuel valve
  • Helps control fuel delivery through the generator fuel system
  • Allows fuel flow to be controlled as intended by the equipment design
  • Helps restore proper fuel-system operation
  • Designed to match the original equipment mounting and connection configuration
  • Works with applicable fuel hoses and fuel-system components
  • Suitable for replacing leaking, damaged, restricted, or malfunctioning fuel valves
  • Direct replacement for equipment specifying LH1000I-373000
  • Sold individually

Fuel Valve Function & Importance

The LH1000I-373000 Fuel Valve serves as a fuel-control component between portions of the generator's fuel delivery system. Parts diagrams show the assembly positioned between fuel-system components including the fuel tank, inline fuel filter, and fuel hose leading toward the carburetor.

A simplified fuel-system arrangement can be represented as:

Fuel Tank → Fuel Hose / Filter → LH1000I-373000 Fuel Valve → Fuel Hose → Carburetor / Engine

The valve allows the fuel supply to be controlled according to the equipment's operating procedure. A damaged or malfunctioning valve may contribute to:

  • Restricted fuel flow
  • Difficulty starting the generator
  • Engine fuel starvation
  • Fuel leakage
  • Inability to properly shut off fuel flow
  • Intermittent engine operation
  • Loose or damaged fuel-hose connections
  • Improper fuel-system operation

Because gasoline fuel systems require secure, leak-free connections, a damaged valve should be replaced before the equipment is returned to service.


Common Reasons for Replacement & Inspection

Replacement of the Homelite LH1000I-373000 Fuel Valve may be appropriate if the original has:

  • Developed a fuel leak
  • Become cracked or physically damaged
  • Become difficult to operate
  • Failed to open or close properly
  • Developed restricted internal fuel flow
  • Developed damaged hose connections
  • Become loose at its mounting location
  • Sustained impact damage
  • Deteriorated from extended service
  • Been damaged during fuel-system maintenance

When replacing the valve, inspect the surrounding fuel hoses, hose clips, inline fuel filter, fuel tank connections, mounting hardware, and carburetor-side fuel line.

OEM diagrams for compatible generator applications show LH1000I-373000 alongside the inline fuel filter, hose clamps, fuel hoses, and fuel tank components, making these useful areas to inspect whenever servicing the valve.


Installation & Maintenance Considerations

Before replacing LH1000I-373000:

  1. Shut off the generator completely and allow the engine and exhaust components to cool.
  2. Disconnect the spark plug or otherwise prevent accidental starting.
  3. Work in a well-ventilated area away from flames, sparks, heaters, cigarettes, or other ignition sources.
  4. Drain or safely isolate the fuel supply as required before disconnecting fuel-system components.
  5. Note the original fuel valve position, orientation, and hose routing.
  6. Carefully disconnect the applicable fuel hoses.
  7. Remove the original valve and inspect the surrounding mounting area.
  8. Check fuel hoses and clamps for cracking, deterioration, looseness, or damage.
  9. Compare the replacement LH1000I-373000 Fuel Valve with the original.
  10. Install the replacement in the correct factory orientation.
  11. Reconnect the applicable fuel hoses and securing clips.
  12. Verify that all fuel connections are properly seated.
  13. Operate the valve through its intended range and verify proper movement.
  14. Carefully inspect the system for fuel leakage before starting the generator.
  15. Reinstall all applicable covers and components.
  16. Test generator operation in a properly ventilated outdoor location according to the manufacturer's instructions.

Fitment & Important Notes

  • Verify compatibility with your exact Homelite equipment model, model number, serial number, and production revision before ordering.
  • Match part number LH1000I-373000 directly with the applicable OEM parts documentation.
  • LH1000I-373000 is identified as a Fuel Valve and as a Fuel Switch Assembly in applicable parts documentation.
  • Documented applications include compatible digital inverter generator configurations such as the Homelite UTi2100S and related generator platforms.
  • The exact installation position, fuel-line routing, and equipment compatibility are model dependent.
  • Do not assume every Homelite generator uses LH1000I-373000.
  • Fuel valves that appear similar may differ in hose connections, mounting configuration, internal flow characteristics, dimensions, and equipment compatibility.
  • Do not select a replacement solely by visual appearance.
  • Use LH1000I-373000 as the primary OEM fitment reference.
  • Inspect fuel hoses, clamps, and associated fittings whenever replacing the valve.
  • Never operate equipment with a known fuel leak.
  • Keep gasoline and fuel-system components away from sparks, flames, and other ignition sources during service.
  • Do not drill, cut, reshape, or otherwise modify the valve to force fitment.
  • This listing is for one Homelite LH1000I-373000 Fuel Valve only unless otherwise specified. Fuel hoses, filters, clamps, tanks, carburetors, knobs, and other fuel-system components are sold separately unless explicitly included.
  • Match Homelite LH1000I-373000 with your equipment's OEM parts documentation before ordering to ensure proper fitment.

Explore All Products

Shop Now

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare