Skip to content

Country

Generac 06705700PM 2.2L Diesel Maintenance Kit – Genuine OEM Replacement Oil, Fuel & Paper Air Filter Service Kit

by Generac
Original price $70.00 - Original price $70.00
Original price
$70.00
$70.00 - $70.00
Current price $70.00

Part Number: 06705700PM
Category: Generator Parts & Accessories → Maintenance Kits → Oil, Fuel & Air Filter Kits
Type: Generac 06705700PM 2.2L Diesel Maintenance Kit – Genuine OEM Replacement Oil, Fuel & Paper Air Filter Service Kit


The Generac 06705700PM 2.2L Diesel Maintenance Kit is a genuine OEM service kit designed for compatible Generac generator systems equipped with designated 2.2-liter diesel engines. This convenient maintenance package includes essential oil, fuel, and paper air filtration components to support scheduled engine servicing. Manufactured to original equipment specifications, the kit helps maintain clean lubrication, dependable fuel delivery, proper intake airflow, and reliable generator performance.


Key Features & Benefits

  • Part Number: 06705700PM
  • Genuine OEM Generac maintenance kit
  • Designed for compatible 2.2L diesel generator engines
  • Includes essential engine filtration components
  • Supports scheduled generator maintenance
  • Helps remove contaminants from engine oil
  • Helps maintain clean and dependable fuel delivery
  • Filters dirt, dust, and debris from incoming engine air
  • Supports proper lubrication, combustion, and airflow
  • Helps protect critical internal engine components
  • Convenient service kit reduces the need to source filters separately
  • Manufactured to original equipment specifications

Technical Specifications

  • Part Number: 06705700PM
  • Manufacturer: Generac
  • Product Type: Diesel Engine Maintenance Kit
  • Engine Application: Select 2.2L diesel engines
  • Oil Filter: Included
  • Fuel Filter: Included
  • Air Filter Type: Paper element
  • Air Filter: Included
  • Application: Scheduled generator engine maintenance
  • OEM Parts: Yes
  • Quantity: One Maintenance Kit

Kit Components

The Generac 06705700PM Maintenance Kit includes filtration components for:

  • Engine oil filtration
  • Diesel fuel filtration
  • Engine intake-air filtration
  • Routine 2.2L diesel engine servicing

Kit contents and component designs may be revised by the manufacturer. Confirm the current package contents and compare each included component with the equipment’s maintenance requirements before installation.


Compatible Applications

The Generac 06705700PM Diesel Maintenance Kit is designed for select:

  • Generac generator systems
  • Compatible 2.2L diesel generator engines
  • Standby and backup power equipment
  • Diesel engine preventive-maintenance programs
  • Generator fleet service applications
  • Equipment requiring OEM maintenance kit 06705700PM

Always verify the generator model, serial number, engine model, filter configurations, connection sizes, parts diagram, and original maintenance-kit number before ordering to ensure proper compatibility.


Function of the Maintenance Kit

The 06705700PM Diesel Maintenance Kit is designed to:

  • Replace essential filters during scheduled engine service
  • Remove contaminants from circulating engine oil
  • Help provide clean diesel fuel to the injection system
  • Capture dirt and debris from incoming engine air
  • Support proper engine lubrication
  • Maintain reliable fuel-system operation
  • Promote clean airflow and efficient combustion
  • Help reduce premature wear on internal engine components
  • Support dependable generator starting and operation
  • Simplify routine preventive maintenance

Regular replacement of the oil, fuel, and air filters helps maintain engine efficiency and supports long-term generator reliability.


Common Signs Maintenance Is Needed

Service the generator or replace the applicable filters if you notice:

  • The recommended maintenance interval has been reached
  • Oil filter is leaking, damaged, or heavily contaminated
  • Fuel filter shows contamination or restricted flow
  • Air filter contains excessive dirt or debris
  • Difficult or extended engine starting
  • Rough or inconsistent engine operation
  • Reduced generator performance
  • Increased fuel consumption
  • Unusual exhaust smoke
  • Low oil pressure or lubrication concerns
  • Maintenance records show overdue filter replacement

These symptoms may have several causes. Inspect the complete engine, fuel, lubrication, and intake systems before assuming that filter replacement alone will correct the issue.


Installation & Service Notes

  • Place the generator in the off position and disable automatic startup.
  • Disconnect the starting battery and isolate all available power sources.
  • Allow the engine and exhaust components to cool completely.
  • Follow the manufacturer’s lockout and tagout procedures.
  • Clean the areas surrounding each filter before removal.
  • Drain or contain engine oil and diesel fuel using approved service equipment.
  • Remove each old filter according to the manufacturer’s maintenance instructions.
  • Compare the replacement filters with the original components before installation.
  • Install each filter in the correct location and orientation.
  • Lubricate filter seals only where instructed by the manufacturer.
  • Tighten filters according to the specified installation procedure.
  • Refill the engine with the approved oil type and quantity.
  • Prime or bleed the diesel fuel system when required.
  • Inspect all service areas for oil, fuel, or air leaks.
  • Run and test the generator according to Generac service procedures.

Important: Diesel fuel and used engine oil must be handled and disposed of according to applicable regulations. Generator systems can start automatically and may contain hazardous electrical voltage. Service should be performed by a qualified generator technician. Always verify the generator model, serial number, engine model, filter configurations, and maintenance-kit number before ordering.


Maintenance Recommendations

  • Follow Generac’s specified service intervals for the applicable generator.
  • Record the service date, engine hours, and filters replaced.
  • Inspect filters more frequently in dusty or demanding environments.
  • Use only the manufacturer-approved engine oil and diesel fuel.
  • Check the engine oil level before and after maintenance.
  • Inspect fuel lines, fittings, and seals for leaks or deterioration.
  • Keep dirt and debris away from exposed oil, fuel, and air passages.
  • Do not operate the engine without the correct filters installed.
  • Replace damaged seals and service hardware as required.
  • Keep a spare maintenance kit available for scheduled generator service.
  • Use genuine OEM service components to maintain proper fit, filtration, and dependable generator performance.

Explore All Products

Shop Now

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare