Skip to content

Country

General Pump TS2021NP-VRT3-310EZ Pump Made Ready with Thermal Relief – 5.6 GPM 3500 PSI

Original price $825.00 - Original price $825.00
Original price
$825.00
$825.00 - $825.00
Current price $825.00

Part Number: TS2021NP-VRT3-310EZ
Category: Pressure Washer Pumps → Triplex Pumps → Ready-to-Install Pump Assemblies
Type: General Pump TS2021NP-VRT3-310EZ Pump Made Ready with Thermal Relief


The General Pump TS2021NP-VRT3-310EZ Pump Made Ready with Thermal Relief (Part #TS2021NP-VRT3-310EZ) is a factory-configured, ready-to-install triplex pressure washer pump assembly engineered for heavy-duty commercial and industrial cleaning applications. Built around the General Pump TS2021NP triplex pump, this complete assembly comes pre-equipped with a VRT3-310EZ unloader valve and thermal relief valve, minimizing installation time while providing reliable pressure regulation and enhanced pump protection.


Key Features & Benefits

  • Genuine General Pump ready-to-install pump assembly
  • Part Number: TS2021NP-VRT3-310EZ
  • Built around the General Pump TS2021NP triplex pump
  • Pre-installed VRT3-310EZ unloader valve
  • Includes factory-installed thermal relief valve
  • Rated for 5.6 GPM at 3,500 PSI
  • Low-speed 1,450 RPM operation for extended pump life
  • 24 mm solid shaft configuration
  • Compatible with systems requiring approximately 13.5 BHP (17.5 GHP)
  • Reduces installation time with factory-installed components
  • Helps protect the pump from overheating during bypass operation
  • Designed for heavy-duty commercial and industrial pressure washer systems

Technical Specifications

Part Number: TS2021NP-VRT3-310EZ

Pump Model: TS2021NP

Manufacturer: General Pump (GP)

Product Type: Pump Made Ready Assembly

Maximum Flow Rate: 5.6 GPM

Maximum Pressure: 3,500 PSI

Maximum Speed: 1,450 RPM

Brake Horsepower (BHP): 13.5

Gas Horsepower (GHP): 17.5

Shaft Size: 24 mm

Unloader Valve: VRT3-310EZ

Thermal Relief Valve: Included

Weight: 41 lbs

OEM Replacement: Yes


Compatible Applications

Designed for use with compatible pressure washer systems utilizing:

  • General Pump TS2021NP pump applications
  • 24 mm solid shaft drive systems
  • Belt-drive pressure washers
  • Gear-drive pressure washers
  • Commercial pressure washers
  • Industrial pressure washers
  • Agricultural cleaning equipment
  • Municipal cleaning equipment
  • Equipment repair and replacement projects
  • OEM equipment installations

Always verify shaft size, drive configuration, mounting dimensions, and pressure/flow requirements before installation.


Function of the Pump Made Ready Assembly

The TS2021NP-VRT3-310EZ assembly helps:

  • Deliver up to 5.6 GPM of water flow
  • Produce operating pressures up to 3,500 PSI
  • Regulate system pressure through the integrated VRT3-310EZ unloader valve
  • Protect the pump during bypass operation with the thermal relief valve
  • Reduce installation time with a factory-configured assembly
  • Provide reliable, high-performance cleaning for demanding commercial and industrial applications

The low-speed 1,450 RPM design reduces wear and operating temperatures, helping maximize pump longevity and performance.


Common Signs Replacement Is Needed

Replace the pump assembly if you notice:

  • Low operating pressure
  • Reduced water flow
  • Excessive pump noise
  • External water or oil leaks
  • Pump overheating
  • Unloader valve malfunction
  • Cracked or damaged pump housing
  • Excessive internal wear
  • Thermal relief valve malfunction

Replacing the complete pump assembly restores pressure washer performance while minimizing service time and equipment downtime.


Installation & Service Notes

  • Shut down the pressure washer and relieve all system pressure.
  • Verify compatibility with the drive system, shaft size, horsepower, and mounting configuration.
  • Install the pump according to the manufacturer's specifications.
  • Connect the water inlet, high-pressure outlet, and required plumbing.
  • Verify the VRT3-310EZ unloader valve and thermal relief valve are properly installed.
  • Prime the pump with water before startup.
  • Inspect the system for leaks and verify proper operating pressure after installation.

Important: Never operate the pump without an adequate water supply. Running the pump dry or allowing prolonged bypass operation without a functioning thermal relief valve can significantly reduce pump service life.


Maintenance Recommendations

  • Inspect the pump regularly for leaks and abnormal operating noise.
  • Check pump oil level and service according to General Pump maintenance recommendations.
  • Verify proper operation of the VRT3-310EZ unloader valve.
  • Inspect the thermal relief valve periodically for proper function.
  • Flush the system after use when pumping dirty or corrosive water.
  • Use only genuine OEM General Pump replacement parts and accessories to maintain maximum performance, reliability, and long service life.

Explore All Products

Shop Now

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare