Skip to content

Country

Mi-T-M EBOX-0002-M ePowerStation eBox – Genuine OEM 120V Power Distribution Box

by Mi-T-M
Original price $660.00 - Original price $660.00
Original price
$660.00
$660.00 - $660.00
Current price $660.00

Part Number: EBOX-0002-M
Category: Portable Power Equipment → ePowerStation Components → Power Distribution Boxes
Type: Mi-T-M EBOX-0002-M ePowerStation eBox – Genuine OEM 120V Power Distribution Box


The Mi-T-M EBOX-0002-M ePowerStation eBox is a genuine OEM power-distribution component designed for select compatible Mi-T-M ePowerStation systems. Featuring a designated 120V configuration, this eBox provides the electrical connection and distribution interface needed to supply approved 120V equipment and loads from a compatible portable power station.

Image shown for illustrative purposes only


Key Features & Benefits

  • Part Number: EBOX-0002-M
  • Genuine OEM Mi-T-M component
  • Replacement ePowerStation eBox
  • Dedicated 120V power-distribution configuration
  • Designed for select compatible Mi-T-M ePowerStation systems
  • Provides an electrical interface for approved 120V loads
  • Supports mobile and temporary power applications
  • Helps restore the power station’s output functionality
  • Designed for secure installation in the designated system location
  • Suitable for commercial, industrial, maintenance, and jobsite use
  • Manufactured to original equipment specifications
  • Intended for use only with approved Mi-T-M equipment

Technical Specifications

  • Part Number: EBOX-0002-M
  • Manufacturer: Mi-T-M
  • Product Type: ePowerStation eBox
  • Component Type: Power Distribution Box
  • Voltage Configuration: 120V
  • Application: Compatible Mi-T-M ePowerStation systems
  • Function: Electrical power connection and distribution
  • OEM Component: Yes
  • Quantity: One eBox
  • Receptacle Configuration: Verify current manufacturer specifications
  • Current, Frequency, and Phase Ratings: Verify the applicable product documentation
  • Included Cords, Adapters, and Hardware: Verify current manufacturer packaging

Compatible Applications

The Mi-T-M EBOX-0002-M eBox is designed for select:

  • Mi-T-M mobile ePowerStation systems
  • Compatible portable battery power stations
  • Approved 120V power-distribution configurations
  • Construction and maintenance jobsites
  • Mobile service operations
  • Temporary and emergency power applications
  • Commercial and industrial equipment
  • Systems requiring OEM eBox EBOX-0002-M

Compatibility is system-specific. Confirm the complete ePowerStation model, serial number, battery and inverter configuration, output voltage, receptacle requirements, connector layout, mounting interface, electrical schematic, and original part number before purchasing.


Function of the ePowerStation eBox

The EBOX-0002-M eBox is designed to:

  • Interface with a compatible Mi-T-M ePowerStation
  • Provide designated 120V power distribution
  • Connect approved electrical loads to the power system
  • Maintain the manufacturer-specified output arrangement
  • Support compatible receptacle and connector configurations
  • Provide a centralized power-distribution point
  • Help restore electrical-output functionality
  • Support portable power delivery at approved locations
  • Maintain proper integration with the power station’s inverter and protective systems

The eBox does not increase the ePowerStation’s available output. Total power remains limited by the battery, inverter, wiring, receptacle, protective-device, continuous-power, and surge-power ratings of the complete system.


Typical Applications

When installed on a compatible Mi-T-M ePowerStation, the EBOX-0002-M may support approved 120V:

  • Construction tools
  • Maintenance equipment
  • Lighting systems
  • Mobile service equipment
  • Battery chargers
  • Temporary jobsite equipment
  • Emergency backup loads
  • Commercial and industrial devices
  • Indoor equipment where engine exhaust is undesirable

Always verify the voltage, amperage, frequency, phase, continuous wattage, starting wattage, grounding requirements, and connector type of each connected load.


Common Signs Inspection or Replacement May Be Needed

Inspect or replace the eBox if you notice:

  • No output from one or more designated receptacles
  • Intermittent electrical operation
  • Cracked, loose, or damaged receptacles
  • Burn marks, melting, discoloration, or overheating
  • Damaged plugs, terminals, connectors, or covers
  • Cracked or impact-damaged housing
  • Corrosion or suspected moisture intrusion
  • Loose or damaged mounting points
  • Module does not seat or secure correctly
  • Circuit protection repeatedly trips with a verified acceptable load
  • Equipment diagnostics indicate a power-distribution fault

Output problems may also result from a depleted battery, inverter fault, damaged wiring, incorrect operating mode, overloaded circuit, faulty connected equipment, or system-protection condition. Diagnose the complete ePowerStation before replacing the eBox.


Installation & Service Notes

  • Shut down the ePowerStation completely.
  • Disconnect all connected loads and charging sources.
  • Follow the manufacturer’s shutdown and electrical-isolation procedures.
  • Confirm that the system is de-energized before removing or installing components.
  • Keep the eBox and its connections clean and dry.
  • Inspect the mounting interface and electrical contacts for damage.
  • Compare the EBOX-0002-M with the original component.
  • Install the eBox in the specified position and orientation.
  • Confirm that all connectors are fully seated.
  • Engage every required latch, lock, cover, and retaining device.
  • Do not force connectors or modify the eBox.
  • Restore power according to the Mi-T-M operating instructions.
  • Test the system initially without a connected load when specified.
  • Connect only compatible 120V loads within the system ratings.
  • Verify proper operation before returning the equipment to normal service.

Important: Portable power equipment can produce hazardous electrical voltage and current. Installation, diagnosis, or internal service should be performed by qualified personnel following applicable electrical codes and Mi-T-M procedures. Never open, modify, bypass, or repair sealed electrical components unless expressly authorized by the manufacturer.

Explore All Products

Shop Now

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare