Skip to content

Country

Mi-T-M EBOX-0003-M ePowerStation EPS Electrical Box – Genuine OEM 120V GFCI Power Distribution Box

by Mi-T-M
Original price $799.99 - Original price $799.99
Original price
$799.99
$799.99 - $799.99
Current price $799.99

Part Number: EBOX-0003-M
Category: Portable Power Equipment → ePowerStation Components → Electrical Distribution Boxes
Type: Mi-T-M EBOX-0003-M ePowerStation EPS Electrical Box – Genuine OEM 120V GFCI Power Distribution Box


The Mi-T-M EBOX-0003-M EPS Electrical Box is a genuine OEM power-distribution component designed for select compatible Mi-T-M ePowerStation systems. Featuring a designated 120V configuration with ground-fault circuit-interrupter protection, this electrical box provides the connection and distribution interface for approved equipment and electrical loads.

Image shown for illustrative purposes only


Key Features & Benefits

  • Part Number: EBOX-0003-M
  • Genuine OEM Mi-T-M electrical component
  • Replacement ePowerStation EPS electrical box
  • Dedicated 120V power-distribution configuration
  • Equipped with GFCI-protected output functionality
  • Designed for select compatible Mi-T-M ePowerStation systems
  • Provides an interface for approved 120V electrical loads
  • GFCI protection helps reduce ground-fault electrical hazards
  • Supports mobile and temporary power applications
  • Helps restore the power station’s electrical-output functionality
  • Manufactured to original equipment specifications
  • Intended for use only with approved Mi-T-M equipment

Technical Specifications

  • Part Number: EBOX-0003-M
  • Manufacturer: Mi-T-M
  • Product Type: EPS Electrical Box
  • Component Type: GFCI Power Distribution Box
  • Voltage Configuration: 120V
  • Protection Type: Ground-Fault Circuit Interrupter
  • Application: Compatible Mi-T-M ePowerStation systems
  • Function: Protected electrical power connection and distribution
  • OEM Component: Yes
  • Quantity: One Electrical Box
  • Receptacle Configuration: Verify current manufacturer specifications
  • Current, Frequency, and Phase Ratings: Verify applicable Mi-T-M documentation
  • Included Cords, Adapters, Covers, and Hardware: Verify current packaging

Compatible Applications

The Mi-T-M EBOX-0003-M Electrical Box is designed for select:

  • Mi-T-M mobile ePowerStation systems
  • Compatible EPS portable battery power stations
  • Approved 120V GFCI-protected configurations
  • Construction and maintenance jobsites
  • Mobile service operations
  • Temporary and emergency power applications
  • Commercial and industrial portable-power equipment
  • Systems requiring OEM electrical box EBOX-0003-M

Compatibility is system-specific. Confirm the complete ePowerStation model, serial number, battery and inverter configuration, output voltage, receptacle requirements, connector layout, mounting interface, electrical schematic, and original part number before purchasing.


Function of the EPS Electrical Box

The EBOX-0003-M Electrical Box is designed to:

  • Interface with a compatible Mi-T-M ePowerStation
  • Provide designated 120V electrical distribution
  • Connect approved electrical loads to the portable-power system
  • Provide ground-fault circuit-interrupter protection
  • Interrupt power when a qualifying ground-fault imbalance is detected
  • Maintain the manufacturer-specified receptacle arrangement
  • Support compatible plugs and connected equipment
  • Help restore protected electrical-output functionality
  • Integrate with the system’s inverter and circuit-protection components
  • Support mobile power delivery at approved locations

The electrical box does not increase the ePowerStation’s available output. Total power remains limited by the battery, inverter, wiring, receptacles, protective devices, and continuous and surge ratings of the complete system.


Understanding GFCI Protection

A GFCI monitors the electrical current flowing through a protected circuit. If it detects a qualifying difference between outgoing and returning current, it rapidly interrupts power to help reduce the risk of electrical shock.

GFCI protection does not:

  • Make wet electrical equipment safe to use
  • Protect against every possible electrical hazard
  • Replace proper grounding and bonding
  • Increase the rated capacity of the receptacle or power station
  • Permit damaged cords, plugs, or tools to remain in service
  • Eliminate the need to follow applicable electrical codes

The GFCI should be tested according to Mi-T-M instructions before use and at the recommended service interval.


Typical Applications

When installed on a compatible ePowerStation, the EBOX-0003-M may support approved 120V:

  • Construction tools
  • Maintenance equipment
  • Lighting systems
  • Mobile service equipment
  • Battery chargers
  • Temporary jobsite equipment
  • Emergency backup loads
  • Commercial and industrial devices
  • Equipment used where GFCI-protected power is required

Always verify the voltage, amperage, frequency, phase, continuous wattage, starting wattage, grounding requirements, and plug configuration of every connected device.


Common Signs Inspection or Replacement May Be Needed

Inspect or replace the electrical box if you notice:

  • No output from one or more receptacles
  • GFCI will not reset after loads are disconnected
  • GFCI test function does not trip the protected circuit
  • Intermittent electrical operation
  • Cracked, loose, scorched, or damaged receptacles
  • Burn marks, melting, discoloration, or overheating
  • Damaged terminals, connectors, covers, or housing
  • Corrosion or suspected moisture intrusion
  • Loose or damaged mounting points
  • Electrical box does not seat or secure correctly
  • Equipment diagnostics indicate a distribution fault

Repeated GFCI tripping may indicate a defective connected device, wet cord, damaged wiring, insulation fault, overloaded circuit, moisture intrusion, or internal system problem. Identify and correct the cause before resetting or replacing the electrical box.


Installation & Service Notes

  • Shut down the ePowerStation completely.
  • Disconnect every load and charging source.
  • Follow the manufacturer’s electrical-isolation procedure.
  • Confirm that the system is de-energized before service.
  • Keep the electrical box, receptacles, and connectors clean and dry.
  • Inspect the mounting interface and contacts for damage or contamination.
  • Compare the EBOX-0003-M with the original component.
  • Install it in the specified position and orientation.
  • Confirm that all electrical connections are fully seated.
  • Engage every required latch, lock, cover, and retaining device.
  • Do not force connectors or modify wiring.
  • Restore power according to Mi-T-M operating instructions.
  • Test the GFCI using its designated test and reset controls.
  • Connect only compatible 120V loads within system ratings.
  • Verify stable output before returning the equipment to normal service.

Important: This equipment can produce hazardous voltage and current. Installation, diagnosis, and internal electrical service should be performed by qualified personnel following Mi-T-M procedures and applicable electrical codes. Never bypass or defeat the GFCI, breakers, interlocks, grounding provisions, or protective covers.


Electrical Safety Recommendations

  • Confirm that all connected equipment is rated for 120V operation.
  • Test the GFCI before use according to manufacturer instructions.
  • Do not use the output if the GFCI fails its test or reset procedure.
  • Never repeatedly reset a GFCI without identifying why it tripped.
  • Do not exceed the receptacle, circuit, inverter, or system ratings.
  • Account for motor and compressor starting current.
  • Use only correctly rated extension cords, plugs, and distribution equipment.
  • Remove damaged, wet, overheated, or modified components from service.
  • Keep receptacle covers closed when outputs are unused.
  • Follow all applicable grounding and bonding requirements.
  • Keep the system away from standing water and unsuitable conditions.
  • Have recurring electrical faults inspected by a qualified technician.

Ordering Notes

  • Confirm that EBOX-0003-M is the required part number.
  • Match the electrical box to the complete Mi-T-M ePowerStation model and serial number.
  • Verify that the application requires a 120V GFCI configuration.
  • Compare the receptacles, connectors, mounting points, and locking arrangement.
  • Review the applicable electrical schematic and parts documentation.
  • Confirm the required current, frequency, phase, and protection ratings.
  • Verify whether cords, covers, adapters, keys, or hardware are included.
  • Do not confuse EBOX-0003-M with a standard 120V or 120/240V eBox.
  • Do not order solely by appearance, as similar boxes may use different electrical configurations.

Maintenance Recommendations

  • Inspect the housing, receptacles, connectors, and mounting points before use.
  • Test the GFCI according to the Mi-T-M maintenance schedule.
  • Keep electrical contacts and receptacles clean and dry.
  • Confirm that the electrical box remains securely installed.
  • Keep unused receptacles covered.
  • Avoid exceeding the rated load of any output or the complete system.
  • Protect the electrical box from impact, chemicals, and excessive moisture.
  • Address overheating, contact damage, or repeated GFCI trips immediately.
  • Do not modify wiring, receptacles, GFCI devices, or protective components.
  • Follow the inspection and service schedule for the complete ePowerStation.
  • Use genuine OEM Mi-T-M components to maintain proper fit, electrical compatibility, GFCI protection, and dependable portable-power performance.

Explore All Products

Shop Now

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare