{"product_id":"u-m-r-kit-vrt3-160-unloader-ready-kit-for-pumps-up-to-2320-psi-with-3-8-fpt-inlet-1-4-fpt-outlet-oem-replacement-part","title":"U.M.R. Kit VRT3-160 Unloader Ready Kit for Pumps Up to 2320 PSI with 3\/8\" FPT Inlet \u0026 1\/4\" FPT Outlet – OEM Replacement Part","description":"\u003cp data-start=\"72\" data-end=\"222\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong data-start=\"72\" data-end=\"88\"\u003ePart Number:\u003c\/strong\u003e 5553\u003cbr data-start=\"93\" data-end=\"96\"\u003e\u003cstrong data-start=\"96\" data-end=\"109\"\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Unloader Valves → Unloader Ready Kits\u003cbr data-start=\"171\" data-end=\"174\"\u003e\u003cstrong data-start=\"174\" data-end=\"183\"\u003eType:\u003c\/strong\u003e U.M.R. Kit VRT3-160 Unloader Ready Kit\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"224\" data-end=\"227\"\u003e\n\u003cp data-start=\"363\" data-end=\"791\"\u003eThe \u003cstrong data-start=\"367\" data-end=\"422\"\u003eU.M.R. Kit VRT3-160 Unloader Ready Kit (Part #5553)\u003c\/strong\u003e is a complete OEM replacement solution designed to simplify the replacement of worn, damaged, or malfunctioning pressure-actuated unloader valves on pressure washer systems operating up to \u003cstrong data-start=\"612\" data-end=\"625\"\u003e2,320 PSI\u003c\/strong\u003e. This convenient kit includes the essential components needed to quickly install a new unloader assembly and restore proper pressure regulation and bypass operation.\u003c\/p\u003e\n\u003cp data-start=\"363\" data-end=\"791\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cem\u003eImage shown for illustrative purposes only\u003c\/em\u003e\u003cb id=\"docs-internal-guid-d73c810c-7fff-5cd4-7b0a-7d56777a8e33\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr data-start=\"1491\" data-end=\"1494\"\u003e\n\u003ch2 data-section-id=\"939trr\" data-start=\"1496\" data-end=\"1522\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1524\" data-end=\"2050\"\u003e\n\u003cli data-section-id=\"t8iyqo\" data-start=\"1524\" data-end=\"1579\"\u003eComplete Unloader Made Ready (U.M.R.) replacement kit\u003c\/li\u003e\n\u003cli data-section-id=\"q7v5gr\" data-start=\"1580\" data-end=\"1626\"\u003eIncludes VRT3-160 pressure-actuated unloader\u003c\/li\u003e\n\u003cli data-section-id=\"1sm92zx\" data-start=\"1627\" data-end=\"1673\"\u003eDesigned for pumps operating up to 2,320 PSI\u003c\/li\u003e\n\u003cli data-section-id=\"13b4fzb\" data-start=\"1674\" data-end=\"1726\"\u003eSimplifies unloader replacement and system repairs\u003c\/li\u003e\n\u003cli data-section-id=\"nb6laj\" data-start=\"1727\" data-end=\"1780\"\u003eHelps protect pumps from excessive pressure buildup\u003c\/li\u003e\n\u003cli data-section-id=\"jkfveb\" data-start=\"1781\" data-end=\"1817\"\u003eSupports reliable bypass operation\u003c\/li\u003e\n\u003cli data-section-id=\"sylptu\" data-start=\"1818\" data-end=\"1859\"\u003eRestores consistent pressure regulation\u003c\/li\u003e\n\u003cli data-section-id=\"12u4db8\" data-start=\"1860\" data-end=\"1911\"\u003eIncludes installation accessories for quick setup\u003c\/li\u003e\n\u003cli data-section-id=\"tdgafi\" data-start=\"1912\" data-end=\"1977\"\u003eSuitable for commercial and residential pressure washer systems\u003c\/li\u003e\n\u003cli data-section-id=\"1gztd40\" data-start=\"1978\" data-end=\"2014\"\u003eOEM replacement quality components\u003c\/li\u003e\n\u003cli data-section-id=\"cgzv8s\" data-start=\"2015\" data-end=\"2050\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2052\" data-end=\"2055\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"2057\" data-end=\"2084\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"2086\" data-end=\"2107\"\u003e\u003cstrong data-start=\"2086\" data-end=\"2102\"\u003ePart Number:\u003c\/strong\u003e 5553\u003c\/p\u003e\n\u003cp data-start=\"2109\" data-end=\"2145\"\u003e\u003cstrong data-start=\"2109\" data-end=\"2126\"\u003eProduct Type:\u003c\/strong\u003e Unloader Ready Kit\u003c\/p\u003e\n\u003cp data-start=\"2147\" data-end=\"2166\"\u003e\u003cstrong data-start=\"2147\" data-end=\"2157\"\u003eModel:\u003c\/strong\u003e VRT3-160\u003c\/p\u003e\n\u003cp data-start=\"2168\" data-end=\"2199\"\u003e\u003cstrong data-start=\"2168\" data-end=\"2189\"\u003eMaximum Pressure:\u003c\/strong\u003e 2,320 PSI\u003c\/p\u003e\n\u003cp data-start=\"2201\" data-end=\"2231\"\u003e\u003cstrong data-start=\"2201\" data-end=\"2222\"\u003eInlet Connection:\u003c\/strong\u003e 3\/8\" FPT\u003c\/p\u003e\n\u003cp data-start=\"2233\" data-end=\"2264\"\u003e\u003cstrong data-start=\"2233\" data-end=\"2255\"\u003eOutlet Connection:\u003c\/strong\u003e 1\/4\" FPT\u003c\/p\u003e\n\u003cp data-start=\"2266\" data-end=\"2302\"\u003e\u003cstrong data-start=\"2266\" data-end=\"2284\"\u003eUnloader Type:\u003c\/strong\u003e Pressure Actuated\u003c\/p\u003e\n\u003cp data-start=\"2304\" data-end=\"2328\"\u003e\u003cstrong data-start=\"2304\" data-end=\"2324\"\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr data-start=\"2330\" data-end=\"2333\"\u003e\n\u003ch2 data-section-id=\"x622x5\" data-start=\"2335\" data-end=\"2350\"\u003eKit Contents\u003c\/h2\u003e\n\u003cp data-start=\"2352\" data-end=\"2376\"\u003eThe U.M.R. Kit includes:\u003c\/p\u003e\n\u003cul data-start=\"2378\" data-end=\"2563\"\u003e\n\u003cli data-section-id=\"v6izws\" data-start=\"2378\" data-end=\"2421\"\u003eVRT3-160 pressure-actuated unloader valve\u003c\/li\u003e\n\u003cli data-section-id=\"fc10r6\" data-start=\"2422\" data-end=\"2436\"\u003eInlet filter\u003c\/li\u003e\n\u003cli data-section-id=\"n97anp\" data-start=\"2437\" data-end=\"2470\"\u003eQuick-connect discharge fitting\u003c\/li\u003e\n\u003cli data-section-id=\"rrqxaj\" data-start=\"2471\" data-end=\"2491\"\u003ePush-on hose barbs\u003c\/li\u003e\n\u003cli data-section-id=\"158qt0y\" data-start=\"2492\" data-end=\"2530\"\u003eRoll of thread sealing (Teflon) tape\u003c\/li\u003e\n\u003cli data-section-id=\"1rjbrdv\" data-start=\"2531\" data-end=\"2563\"\u003eInstallation instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2565\" data-end=\"2636\"\u003e\u003cstrong data-start=\"2565\" data-end=\"2574\"\u003eNote:\u003c\/strong\u003e Components are supplied separately and are not pre-assembled.\u003c\/p\u003e\n\u003chr data-start=\"2638\" data-end=\"2641\"\u003e\n\u003ch2 data-section-id=\"1kehdxb\" data-start=\"2643\" data-end=\"2673\"\u003eWhat an Unloader Valve Does\u003c\/h2\u003e\n\u003cp data-start=\"2675\" data-end=\"2749\"\u003eAn unloader valve plays a critical role in pressure washer performance by:\u003c\/p\u003e\n\u003cul data-start=\"2751\" data-end=\"3021\"\u003e\n\u003cli data-section-id=\"1pfj4mk\" data-start=\"2751\" data-end=\"2782\"\u003eRegulating operating pressure\u003c\/li\u003e\n\u003cli data-section-id=\"10qq8f4\" data-start=\"2783\" data-end=\"2848\"\u003eDiverting water flow into bypass when the trigger gun is closed\u003c\/li\u003e\n\u003cli data-section-id=\"6mo2nd\" data-start=\"2849\" data-end=\"2899\"\u003eProtecting pumps from excessive pressure buildup\u003c\/li\u003e\n\u003cli data-section-id=\"qoycqm\" data-start=\"2900\" data-end=\"2950\"\u003eReducing wear on hoses, spray guns, and fittings\u003c\/li\u003e\n\u003cli data-section-id=\"4h0a67\" data-start=\"2951\" data-end=\"2985\"\u003eExtending equipment service life\u003c\/li\u003e\n\u003cli data-section-id=\"10xr06o\" data-start=\"2986\" data-end=\"3021\"\u003eMaintaining safe system operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3023\" data-end=\"3026\"\u003e\n\u003ch2 data-section-id=\"vx2wyp\" data-start=\"3028\" data-end=\"3050\"\u003eCommon Applications\u003c\/h2\u003e\n\u003ch3 data-section-id=\"wcna3b\" data-start=\"3052\" data-end=\"3079\"\u003ePressure Washer Repairs\u003c\/h3\u003e\n\u003cp data-start=\"3081\" data-end=\"3091\"\u003eIdeal for:\u003c\/p\u003e\n\u003cul data-start=\"3093\" data-end=\"3224\"\u003e\n\u003cli data-section-id=\"17wzxhw\" data-start=\"3093\" data-end=\"3125\"\u003eReplacing worn unloader valves\u003c\/li\u003e\n\u003cli data-section-id=\"xssqxu\" data-start=\"3126\" data-end=\"3165\"\u003eRestoring pressure washer performance\u003c\/li\u003e\n\u003cli data-section-id=\"dozobb\" data-start=\"3166\" data-end=\"3198\"\u003eScheduled maintenance upgrades\u003c\/li\u003e\n\u003cli data-section-id=\"1pr46hi\" data-start=\"3199\" data-end=\"3224\"\u003eEquipment refurbishment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1m4yfbj\" data-start=\"3226\" data-end=\"3253\"\u003ePressure Washer Systems\u003c\/h3\u003e\n\u003cp data-start=\"3255\" data-end=\"3268\"\u003eSuitable for:\u003c\/p\u003e\n\u003cul data-start=\"3270\" data-end=\"3426\"\u003e\n\u003cli data-section-id=\"xvja5y\" data-start=\"3270\" data-end=\"3300\"\u003eResidential pressure washers\u003c\/li\u003e\n\u003cli data-section-id=\"n48o3f\" data-start=\"3301\" data-end=\"3332\"\u003eCommercial cleaning equipment\u003c\/li\u003e\n\u003cli data-section-id=\"yt07qn\" data-start=\"3333\" data-end=\"3363\"\u003eMobile pressure washing rigs\u003c\/li\u003e\n\u003cli data-section-id=\"1351n5w\" data-start=\"3364\" data-end=\"3394\"\u003eProperty maintenance systems\u003c\/li\u003e\n\u003cli data-section-id=\"1wpc0sg\" data-start=\"3395\" data-end=\"3426\"\u003eIndustrial cleaning equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3428\" data-end=\"3431\"\u003e\n\u003ch2 data-section-id=\"ctfpuh\" data-start=\"3433\" data-end=\"3456\"\u003ePerformance Benefits\u003c\/h2\u003e\n\u003cul data-start=\"3458\" data-end=\"3683\"\u003e\n\u003cli data-section-id=\"1l1dhfv\" data-start=\"3458\" data-end=\"3487\"\u003eFaster unloader replacement\u003c\/li\u003e\n\u003cli data-section-id=\"1qnerz7\" data-start=\"3488\" data-end=\"3517\"\u003eImproved system reliability\u003c\/li\u003e\n\u003cli data-section-id=\"1n9g3io\" data-start=\"3518\" data-end=\"3549\"\u003eConsistent operating pressure\u003c\/li\u003e\n\u003cli data-section-id=\"1ero2xq\" data-start=\"3550\" data-end=\"3575\"\u003eReduced pressure spikes\u003c\/li\u003e\n\u003cli data-section-id=\"705ixp\" data-start=\"3576\" data-end=\"3602\"\u003eEnhanced pump protection\u003c\/li\u003e\n\u003cli data-section-id=\"75l1fd\" data-start=\"3603\" data-end=\"3627\"\u003eSimplified maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"3b65a9\" data-start=\"3628\" data-end=\"3656\"\u003eReduced equipment downtime\u003c\/li\u003e\n\u003cli data-section-id=\"mto73x\" data-start=\"3657\" data-end=\"3683\"\u003eLong-lasting performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3685\" data-end=\"3688\"\u003e\n\u003ch2 data-section-id=\"22sv21\" data-start=\"3690\" data-end=\"3730\"\u003eSigns Your Unloader Needs Replacement\u003c\/h2\u003e\n\u003cp data-start=\"3732\" data-end=\"3782\"\u003eConsider replacing the unloader if you experience:\u003c\/p\u003e\n\u003cul data-start=\"3784\" data-end=\"3986\"\u003e\n\u003cli data-section-id=\"zta6im\" data-start=\"3784\" data-end=\"3807\"\u003ePressure fluctuations\u003c\/li\u003e\n\u003cli data-section-id=\"1tusf11\" data-start=\"3808\" data-end=\"3831\"\u003ePoor bypass operation\u003c\/li\u003e\n\u003cli data-section-id=\"ldy9cv\" data-start=\"3832\" data-end=\"3862\"\u003eWater leaks around the valve\u003c\/li\u003e\n\u003cli data-section-id=\"1n1a9ox\" data-start=\"3863\" data-end=\"3893\"\u003eReduced cleaning performance\u003c\/li\u003e\n\u003cli data-section-id=\"16eqa1l\" data-start=\"3894\" data-end=\"3919\"\u003eTrigger response issues\u003c\/li\u003e\n\u003cli data-section-id=\"d4j17h\" data-start=\"3920\" data-end=\"3943\"\u003ePump cycling problems\u003c\/li\u003e\n\u003cli data-section-id=\"1l7xs02\" data-start=\"3944\" data-end=\"3986\"\u003eDifficulty maintaining pressure settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3988\" data-end=\"3991\"\u003e\n\u003ch2 data-section-id=\"16dprsq\" data-start=\"3993\" data-end=\"4014\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003col data-start=\"4016\" data-end=\"4419\"\u003e\n\u003cli data-section-id=\"1xqzeet\" data-start=\"4016\" data-end=\"4077\"\u003eShut down the pressure washer and relieve system pressure.\u003c\/li\u003e\n\u003cli data-section-id=\"qbd9zv\" data-start=\"4078\" data-end=\"4114\"\u003eRemove the old unloader assembly.\u003c\/li\u003e\n\u003cli data-section-id=\"zr07hb\" data-start=\"4115\" data-end=\"4207\"\u003eInstall the VRT3-160 unloader and included components according to the instruction sheet.\u003c\/li\u003e\n\u003cli data-section-id=\"14ffsmq\" data-start=\"4208\" data-end=\"4257\"\u003eApply the supplied thread seal tape as needed.\u003c\/li\u003e\n\u003cli data-section-id=\"1ym5zqa\" data-start=\"4258\" data-end=\"4295\"\u003eVerify all connections are secure.\u003c\/li\u003e\n\u003cli data-section-id=\"gag8vy\" data-start=\"4296\" data-end=\"4345\"\u003eTest for leaks and proper pressure regulation.\u003c\/li\u003e\n\u003cli data-section-id=\"1dkowga\" data-start=\"4346\" data-end=\"4419\"\u003eConfirm proper bypass operation before returning equipment to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"4421\" data-end=\"4542\"\u003e\u003cstrong data-start=\"4421\" data-end=\"4435\"\u003eImportant:\u003c\/strong\u003e Ensure all pressure washer components are rated for the intended operating pressure and flow requirements.\u003c\/p\u003e\n\u003chr data-start=\"4544\" data-end=\"4547\"\u003e\n\u003ch2 data-section-id=\"8fimbm\" data-start=\"4549\" data-end=\"4579\"\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul data-start=\"4581\" data-end=\"4856\"\u003e\n\u003cli data-section-id=\"1nlm6i5\" data-start=\"4581\" data-end=\"4633\"\u003eInspect the unloader regularly for wear and leaks.\u003c\/li\u003e\n\u003cli data-section-id=\"1theuje\" data-start=\"4634\" data-end=\"4664\"\u003eKeep inlet filtration clean.\u003c\/li\u003e\n\u003cli data-section-id=\"1nnyne9\" data-start=\"4665\" data-end=\"4715\"\u003eVerify pressure settings during routine service.\u003c\/li\u003e\n\u003cli data-section-id=\"s0pz57\" data-start=\"4716\" data-end=\"4762\"\u003eReplace damaged fittings and seals promptly.\u003c\/li\u003e\n\u003cli data-section-id=\"18er8na\" data-start=\"4763\" data-end=\"4810\"\u003eMonitor bypass operation for proper function.\u003c\/li\u003e\n\u003cli data-section-id=\"1wai22i\" data-start=\"4811\" data-end=\"4856\"\u003eFollow manufacturer maintenance guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mecline","offers":[{"title":"Default Title","offer_id":53429572403563,"sku":null,"price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/U.M.R.KITVRT3-160.avif?v=1782521120","url":"https:\/\/generalsprayers.com\/products\/u-m-r-kit-vrt3-160-unloader-ready-kit-for-pumps-up-to-2320-psi-with-3-8-fpt-inlet-1-4-fpt-outlet-oem-replacement-part","provider":"GeneralSprayers","version":"1.0","type":"link"}