{"product_id":"st-5vh-flow-switch-vertical-horizontal-mount-oem-replacement-part","title":"ST-5VH Flow Switch Vertical \u0026 Horizontal Mount – OEM Replacement Part","description":"\u003cp data-start=\"0\" data-end=\"183\"\u003e\u003cstrong data-start=\"0\" data-end=\"16\"\u003ePart Number:\u003c\/strong\u003e ST-5VH\u003cbr data-start=\"23\" data-end=\"26\"\u003e\u003cstrong data-start=\"26\" data-end=\"39\"\u003eCategory:\u003c\/strong\u003e Pressure Washer Components → Flow Switches → Electrical Control Components\u003cbr data-start=\"114\" data-end=\"117\"\u003e\u003cstrong data-start=\"117\" data-end=\"126\"\u003eType:\u003c\/strong\u003e Suttner ST-5VH Flow Switch – Vertical \u0026amp; Horizontal Mount\u003c\/p\u003e\n\u003chr data-start=\"185\" data-end=\"188\"\u003e\n\u003cp data-start=\"263\" data-end=\"681\"\u003eThe \u003cstrong data-start=\"267\" data-end=\"297\"\u003eSuttner ST-5VH Flow Switch\u003c\/strong\u003e is a genuine OEM flow-activated control device designed to monitor water flow in pressure washer systems, industrial cleaning equipment, and fluid handling applications. Engineered for dependable performance, this switch activates when water flow reaches the required threshold, allowing automated control of burners, pumps, chemical systems, alarms, and other electrical components.\u003c\/p\u003e\n\u003chr data-start=\"1288\" data-end=\"1291\"\u003e\n\u003ch2 data-section-id=\"939trr\" data-start=\"1293\" data-end=\"1319\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1321\" data-end=\"1775\"\u003e\n\u003cli data-section-id=\"1n8ctnm\" data-start=\"1321\" data-end=\"1359\"\u003eGenuine Suttner OEM Replacement Part\u003c\/li\u003e\n\u003cli data-section-id=\"uhe3li\" data-start=\"1360\" data-end=\"1394\"\u003eFlow-activated electrical switch\u003c\/li\u003e\n\u003cli data-section-id=\"1qq7eti\" data-start=\"1395\" data-end=\"1454\"\u003eCompatible with both vertical and horizontal installation\u003c\/li\u003e\n\u003cli data-section-id=\"s3ep00\" data-start=\"1455\" data-end=\"1491\"\u003eReliable 2-wire reed switch design\u003c\/li\u003e\n\u003cli data-section-id=\"gvsjg4\" data-start=\"1492\" data-end=\"1541\"\u003eDetects water flow for automated system control\u003c\/li\u003e\n\u003cli data-section-id=\"1rhv25l\" data-start=\"1542\" data-end=\"1579\"\u003eSupports flow rates from 1 to 8 GPM\u003c\/li\u003e\n\u003cli data-section-id=\"17hvm5s\" data-start=\"1580\" data-end=\"1616\"\u003eRated for pressures up to 5075 PSI\u003c\/li\u003e\n\u003cli data-section-id=\"1iyj6qq\" data-start=\"1617\" data-end=\"1663\"\u003eSuitable for hot and cold water applications\u003c\/li\u003e\n\u003cli data-section-id=\"19141bq\" data-start=\"1664\" data-end=\"1713\"\u003eHelps protect equipment from dry-run conditions\u003c\/li\u003e\n\u003cli data-section-id=\"18stcen\" data-start=\"1714\" data-end=\"1775\"\u003eIdeal for commercial and industrial pressure washer systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1777\" data-end=\"1780\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1782\" data-end=\"1809\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1811\" data-end=\"1836\"\u003e\u003cstrong data-start=\"1811\" data-end=\"1828\"\u003eManufacturer:\u003c\/strong\u003e Suttner\u003c\/p\u003e\n\u003cp data-start=\"1838\" data-end=\"1855\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1848\"\u003eModel:\u003c\/strong\u003e ST-5VH\u003c\/p\u003e\n\u003cp data-start=\"1857\" data-end=\"1886\"\u003e\u003cstrong data-start=\"1857\" data-end=\"1874\"\u003eProduct Type:\u003c\/strong\u003e Flow Switch\u003c\/p\u003e\n\u003cp data-start=\"1888\" data-end=\"1923\"\u003e\u003cstrong data-start=\"1888\" data-end=\"1904\"\u003eSwitch Type:\u003c\/strong\u003e 2-Wire Reed Switch\u003c\/p\u003e\n\u003cp data-start=\"1925\" data-end=\"1954\"\u003e\u003cstrong data-start=\"1925\" data-end=\"1945\"\u003eConnection Size:\u003c\/strong\u003e 3\/8\" FPT\u003c\/p\u003e\n\u003cp data-start=\"1956\" data-end=\"1997\"\u003e\u003cstrong data-start=\"1956\" data-end=\"1972\"\u003eThread Type:\u003c\/strong\u003e Female Pipe Thread (FPT)\u003c\/p\u003e\n\u003cp data-start=\"1999\" data-end=\"2027\"\u003e\u003cstrong data-start=\"1999\" data-end=\"2021\"\u003eMinimum Flow Rate:\u003c\/strong\u003e 1 GPM\u003c\/p\u003e\n\u003cp data-start=\"2029\" data-end=\"2057\"\u003e\u003cstrong data-start=\"2029\" data-end=\"2051\"\u003eMaximum Flow Rate:\u003c\/strong\u003e 8 GPM\u003c\/p\u003e\n\u003cp data-start=\"2059\" data-end=\"2089\"\u003e\u003cstrong data-start=\"2059\" data-end=\"2080\"\u003eMaximum Pressure:\u003c\/strong\u003e 5075 PSI\u003c\/p\u003e\n\u003cp data-start=\"2091\" data-end=\"2121\"\u003e\u003cstrong data-start=\"2091\" data-end=\"2115\"\u003eMaximum Temperature:\u003c\/strong\u003e 176°F\u003c\/p\u003e\n\u003cp data-start=\"2123\" data-end=\"2148\"\u003e\u003cstrong data-start=\"2123\" data-end=\"2144\"\u003eLead Wire Length:\u003c\/strong\u003e 47\"\u003c\/p\u003e\n\u003cp data-start=\"2150\" data-end=\"2198\"\u003e\u003cstrong data-start=\"2150\" data-end=\"2175\"\u003eMounting Orientation:\u003c\/strong\u003e Vertical or Horizontal\u003c\/p\u003e\n\u003cp data-start=\"2200\" data-end=\"2224\"\u003e\u003cstrong data-start=\"2200\" data-end=\"2220\"\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr data-start=\"2226\" data-end=\"2229\"\u003e\n\u003ch2 data-section-id=\"164os46\" data-start=\"2231\" data-end=\"2254\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul data-start=\"2256\" data-end=\"2495\"\u003e\n\u003cli data-section-id=\"1z0el29\" data-start=\"2256\" data-end=\"2281\"\u003ePressure washer systems\u003c\/li\u003e\n\u003cli data-section-id=\"g7mqf6\" data-start=\"2282\" data-end=\"2310\"\u003eHot water pressure washers\u003c\/li\u003e\n\u003cli data-section-id=\"nhcltf\" data-start=\"2311\" data-end=\"2336\"\u003eBurner control circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1wpc0sg\" data-start=\"2337\" data-end=\"2368\"\u003eIndustrial cleaning equipment\u003c\/li\u003e\n\u003cli data-section-id=\"w6g5k5\" data-start=\"2369\" data-end=\"2394\"\u003ePump protection systems\u003c\/li\u003e\n\u003cli data-section-id=\"5rnjcl\" data-start=\"2395\" data-end=\"2426\"\u003eWater flow monitoring systems\u003c\/li\u003e\n\u003cli data-section-id=\"ooleo0\" data-start=\"2427\" data-end=\"2457\"\u003eAutomated equipment controls\u003c\/li\u003e\n\u003cli data-section-id=\"1fqu7u2\" data-start=\"2458\" data-end=\"2495\"\u003eCommercial pressure washing systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2497\" data-end=\"2500\"\u003e\n\u003ch2 data-section-id=\"7zbpd1\" data-start=\"2502\" data-end=\"2527\"\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul data-start=\"2529\" data-end=\"2952\"\u003e\n\u003cli data-section-id=\"183746w\" data-start=\"2529\" data-end=\"2569\"\u003eProvides reliable water flow detection\u003c\/li\u003e\n\u003cli data-section-id=\"7jg42b\" data-start=\"2570\" data-end=\"2619\"\u003eSupports automatic burner and equipment control\u003c\/li\u003e\n\u003cli data-section-id=\"1s0ffpq\" data-start=\"2620\" data-end=\"2673\"\u003eHelps prevent operation without adequate water flow\u003c\/li\u003e\n\u003cli data-section-id=\"on8ept\" data-start=\"2674\" data-end=\"2723\"\u003eFlexible mounting options simplify installation\u003c\/li\u003e\n\u003cli data-section-id=\"1jg7pw4\" data-start=\"2724\" data-end=\"2772\"\u003eReed switch design offers dependable operation\u003c\/li\u003e\n\u003cli data-section-id=\"vjrgev\" data-start=\"2773\" data-end=\"2818\"\u003eSuitable for high-pressure cleaning systems\u003c\/li\u003e\n\u003cli data-section-id=\"edrzn8\" data-start=\"2819\" data-end=\"2858\"\u003eEnhances system safety and efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"2yrtx\" data-start=\"2859\" data-end=\"2903\"\u003eHelps protect pumps and heating components\u003c\/li\u003e\n\u003cli data-section-id=\"o2l119\" data-start=\"2904\" data-end=\"2952\"\u003eDesigned for demanding commercial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2954\" data-end=\"2957\"\u003e\n\u003ch2 data-section-id=\"1hq6yh\" data-start=\"2959\" data-end=\"2978\"\u003eCommon Functions\u003c\/h2\u003e\n\u003cp data-start=\"2980\" data-end=\"3023\"\u003eThe ST-5VH Flow Switch is commonly used to:\u003c\/p\u003e\n\u003cul data-start=\"3025\" data-end=\"3288\"\u003e\n\u003cli data-section-id=\"1b8p1e1\" data-start=\"3025\" data-end=\"3069\"\u003eVerify water flow before burner activation\u003c\/li\u003e\n\u003cli data-section-id=\"k13mfw\" data-start=\"3070\" data-end=\"3120\"\u003eControl hot water pressure washer burner systems\u003c\/li\u003e\n\u003cli data-section-id=\"ra4tmg\" data-start=\"3121\" data-end=\"3179\"\u003eActivate or deactivate electrical circuits based on flow\u003c\/li\u003e\n\u003cli data-section-id=\"15yfbp3\" data-start=\"3180\" data-end=\"3235\"\u003eProtect equipment from low-flow or no-flow conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1sen09b\" data-start=\"3236\" data-end=\"3288\"\u003eMonitor system operation for safety and efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3290\" data-end=\"3293\"\u003e\n\u003ch2 data-section-id=\"8fimbm\" data-start=\"3295\" data-end=\"3325\"\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul data-start=\"3327\" data-end=\"3680\"\u003e\n\u003cli data-section-id=\"e8itdd\" data-start=\"3327\" data-end=\"3375\"\u003eInspect wiring and lead connections regularly.\u003c\/li\u003e\n\u003cli data-section-id=\"bmbvml\" data-start=\"3376\" data-end=\"3437\"\u003eVerify proper switch activation during routine maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"7su624\" data-start=\"3438\" data-end=\"3502\"\u003eInspect for debris or scale buildup that may affect operation.\u003c\/li\u003e\n\u003cli data-section-id=\"14wmewl\" data-start=\"3503\" data-end=\"3564\"\u003eEnsure flow rates remain within specified operating ranges.\u003c\/li\u003e\n\u003cli data-section-id=\"pox7z9\" data-start=\"3565\" data-end=\"3622\"\u003eFollow manufacturer installation and wiring procedures.\u003c\/li\u003e\n\u003cli data-section-id=\"rex0ca\" data-start=\"3623\" data-end=\"3680\"\u003eReplace damaged or malfunctioning switches immediately.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Suttner","offers":[{"title":"Default Title","offer_id":53339177582955,"sku":"ST-5VH","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/ST-5VH.webp?v=1780498881","url":"https:\/\/generalsprayers.com\/products\/st-5vh-flow-switch-vertical-horizontal-mount-oem-replacement-part","provider":"GeneralSprayers","version":"1.0","type":"link"}