{"product_id":"mtm-pressure-switch-1-4-mpt-15-amp-360-psi-oem-replacement-part","title":"MTM Pressure Switch 1\/4\" MPT 15 Amp 360 PSI – OEM Replacement Part","description":"\u003cp data-start=\"0\" data-end=\"211\"\u003e\u003cstrong data-start=\"0\" data-end=\"16\"\u003ePart Number:\u003c\/strong\u003e 6249\u003cbr data-start=\"60\" data-end=\"63\"\u003e\u003cstrong data-start=\"63\" data-end=\"76\"\u003eCategory:\u003c\/strong\u003e Pressure Washer Components → Pressure Switches → Electrical Control Components\u003cbr data-start=\"155\" data-end=\"158\"\u003e\u003cstrong data-start=\"158\" data-end=\"167\"\u003eType:\u003c\/strong\u003e MTM Pressure Switch 1\/4\" MPT 15 Amp 360 PSI\u003c\/p\u003e\n\u003chr data-start=\"213\" data-end=\"216\"\u003e\n\u003cp data-start=\"288\" data-end=\"730\"\u003eThe \u003cstrong data-start=\"292\" data-end=\"339\"\u003eMTM Pressure Switch 1\/4\" MPT 15 Amp 360 PSI\u003c\/strong\u003e is a high-quality OEM pressure-activated electrical control device designed for pressure washer systems, burner controls, and automated fluid management applications. Engineered to respond to changes in system pressure, this switch automatically opens or closes an electrical circuit when predetermined pressure levels are reached, helping improve system efficiency, safety, and automation.\u003c\/p\u003e\n\u003chr data-start=\"1546\" data-end=\"1549\"\u003e\n\u003ch2 data-section-id=\"939trr\" data-start=\"1551\" data-end=\"1577\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1579\" data-end=\"2028\"\u003e\n\u003cli data-section-id=\"1h0xubt\" data-start=\"1579\" data-end=\"1613\"\u003eGenuine MTM OEM Replacement Part\u003c\/li\u003e\n\u003cli data-section-id=\"1wpug6g\" data-start=\"1614\" data-end=\"1636\"\u003eActivates at 360 PSI\u003c\/li\u003e\n\u003cli data-section-id=\"gx8uu1\" data-start=\"1637\" data-end=\"1663\"\u003e15 Amp electrical rating\u003c\/li\u003e\n\u003cli data-section-id=\"uyzpc8\" data-start=\"1664\" data-end=\"1710\"\u003eDurable stainless steel plunger construction\u003c\/li\u003e\n\u003cli data-section-id=\"jw6xs4\" data-start=\"1711\" data-end=\"1755\"\u003eAutomatically responds to pressure changes\u003c\/li\u003e\n\u003cli data-section-id=\"1f7876q\" data-start=\"1756\" data-end=\"1809\"\u003eSupports trigger gun-operated fluid control systems\u003c\/li\u003e\n\u003cli data-section-id=\"1a4tczo\" data-start=\"1810\" data-end=\"1863\"\u003eSuitable for burner and boiler control applications\u003c\/li\u003e\n\u003cli data-section-id=\"pplj9u\" data-start=\"1864\" data-end=\"1906\"\u003eHelps automate pressure washer operation\u003c\/li\u003e\n\u003cli data-section-id=\"4j8yux\" data-start=\"1907\" data-end=\"1971\"\u003eReliable performance in commercial and industrial environments\u003c\/li\u003e\n\u003cli data-section-id=\"1yedagu\" data-start=\"1972\" data-end=\"2028\"\u003eEasy integration into existing pressure washer systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2030\" data-end=\"2033\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"2035\" data-end=\"2062\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"2064\" data-end=\"2091\"\u003e\u003cstrong data-start=\"2064\" data-end=\"2081\"\u003eManufacturer:\u003c\/strong\u003e MTM Hydro\u003c\/p\u003e\n\u003cp data-start=\"2093\" data-end=\"2126\"\u003e\u003cstrong data-start=\"2093\" data-end=\"2110\"\u003eProduct Type:\u003c\/strong\u003e Pressure Switch\u003c\/p\u003e\n\u003cp data-start=\"2128\" data-end=\"2157\"\u003e\u003cstrong data-start=\"2128\" data-end=\"2148\"\u003eConnection Size:\u003c\/strong\u003e 1\/4\" MPT\u003c\/p\u003e\n\u003cp data-start=\"2159\" data-end=\"2198\"\u003e\u003cstrong data-start=\"2159\" data-end=\"2175\"\u003eThread Type:\u003c\/strong\u003e Male Pipe Thread (MPT)\u003c\/p\u003e\n\u003cp data-start=\"2200\" data-end=\"2232\"\u003e\u003cstrong data-start=\"2200\" data-end=\"2224\"\u003eActivation Pressure:\u003c\/strong\u003e 360 PSI\u003c\/p\u003e\n\u003cp data-start=\"2234\" data-end=\"2264\"\u003e\u003cstrong data-start=\"2234\" data-end=\"2255\"\u003eMaximum Pressure:\u003c\/strong\u003e 4100 PSI\u003c\/p\u003e\n\u003cp data-start=\"2266\" data-end=\"2296\"\u003e\u003cstrong data-start=\"2266\" data-end=\"2290\"\u003eMaximum Temperature:\u003c\/strong\u003e 195°F\u003c\/p\u003e\n\u003cp data-start=\"2298\" data-end=\"2327\"\u003e\u003cstrong data-start=\"2298\" data-end=\"2320\"\u003eElectrical Rating:\u003c\/strong\u003e 15 Amp\u003c\/p\u003e\n\u003cp data-start=\"2329\" data-end=\"2366\"\u003e\u003cstrong data-start=\"2329\" data-end=\"2350\"\u003ePlunger Material:\u003c\/strong\u003e Stainless Steel\u003c\/p\u003e\n\u003cp data-start=\"2368\" data-end=\"2391\"\u003e\u003cstrong data-start=\"2368\" data-end=\"2391\"\u003eWire Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2393\" data-end=\"2486\"\u003e\n\u003cli data-section-id=\"13eis2w\" data-start=\"2393\" data-end=\"2418\"\u003eBlue Wire: Common (COM)\u003c\/li\u003e\n\u003cli data-section-id=\"w158gv\" data-start=\"2419\" data-end=\"2452\"\u003eRed Wire: Normally Closed (N\/C)\u003c\/li\u003e\n\u003cli data-section-id=\"1ovnacg\" data-start=\"2453\" data-end=\"2486\"\u003eBrown Wire: Normally Open (N\/O)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2488\" data-end=\"2512\"\u003e\u003cstrong data-start=\"2488\" data-end=\"2508\"\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr data-start=\"2514\" data-end=\"2517\"\u003e\n\u003ch2 data-section-id=\"164os46\" data-start=\"2519\" data-end=\"2542\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul data-start=\"2544\" data-end=\"2797\"\u003e\n\u003cli data-section-id=\"1z0el29\" data-start=\"2544\" data-end=\"2569\"\u003ePressure washer systems\u003c\/li\u003e\n\u003cli data-section-id=\"g7mqf6\" data-start=\"2570\" data-end=\"2598\"\u003eHot water pressure washers\u003c\/li\u003e\n\u003cli data-section-id=\"nhcltf\" data-start=\"2599\" data-end=\"2624\"\u003eBurner control circuits\u003c\/li\u003e\n\u003cli data-section-id=\"16e6chy\" data-start=\"2625\" data-end=\"2649\"\u003eBoiler control systems\u003c\/li\u003e\n\u003cli data-section-id=\"upu5bs\" data-start=\"2650\" data-end=\"2688\"\u003eTrigger gun pressure control systems\u003c\/li\u003e\n\u003cli data-section-id=\"n48o3f\" data-start=\"2689\" data-end=\"2720\"\u003eCommercial cleaning equipment\u003c\/li\u003e\n\u003cli data-section-id=\"e9p5qp\" data-start=\"2721\" data-end=\"2758\"\u003eIndustrial pressure washing systems\u003c\/li\u003e\n\u003cli data-section-id=\"1wcebeq\" data-start=\"2759\" data-end=\"2797\"\u003eAutomated fluid control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2799\" data-end=\"2802\"\u003e\n\u003ch2 data-section-id=\"7zbpd1\" data-start=\"2804\" data-end=\"2829\"\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul data-start=\"2831\" data-end=\"3333\"\u003e\n\u003cli data-section-id=\"fe685z\" data-start=\"2831\" data-end=\"2901\"\u003eAutomatically controls electrical circuits based on pressure changes\u003c\/li\u003e\n\u003cli data-section-id=\"pplj9u\" data-start=\"2902\" data-end=\"2944\"\u003eHelps automate pressure washer operation\u003c\/li\u003e\n\u003cli data-section-id=\"nvacxt\" data-start=\"2945\" data-end=\"3001\"\u003eSupports efficient burner control in hot water systems\u003c\/li\u003e\n\u003cli data-section-id=\"llali5\" data-start=\"3002\" data-end=\"3049\"\u003eReduces unnecessary system operation and wear\u003c\/li\u003e\n\u003cli data-section-id=\"e3cvbh\" data-start=\"3050\" data-end=\"3120\"\u003eStainless steel plunger provides durability and corrosion resistance\u003c\/li\u003e\n\u003cli data-section-id=\"1t7hbim\" data-start=\"3121\" data-end=\"3153\"\u003eReliable activation at 360 PSI\u003c\/li\u003e\n\u003cli data-section-id=\"6d50zi\" data-start=\"3154\" data-end=\"3217\"\u003eDesigned for demanding commercial and industrial applications\u003c\/li\u003e\n\u003cli data-section-id=\"wdbezs\" data-start=\"3218\" data-end=\"3273\"\u003eImproves overall equipment efficiency and reliability\u003c\/li\u003e\n\u003cli data-section-id=\"1gczyia\" data-start=\"3274\" data-end=\"3333\"\u003eHelps protect system components through automated control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3335\" data-end=\"3338\"\u003e\n\u003ch2 data-section-id=\"16kntr9\" data-start=\"3340\" data-end=\"3361\"\u003eWiring Information\u003c\/h2\u003e\n\u003cp data-start=\"3363\" data-end=\"3390\"\u003e\u003cstrong data-start=\"3363\" data-end=\"3377\"\u003eBlue Wire:\u003c\/strong\u003e Common (COM)\u003c\/p\u003e\n\u003cp data-start=\"3392\" data-end=\"3427\"\u003e\u003cstrong data-start=\"3392\" data-end=\"3405\"\u003eRed Wire:\u003c\/strong\u003e Normally Closed (N\/C)\u003c\/p\u003e\n\u003cp data-start=\"3429\" data-end=\"3464\"\u003e\u003cstrong data-start=\"3429\" data-end=\"3444\"\u003eBrown Wire:\u003c\/strong\u003e Normally Open (N\/O)\u003c\/p\u003e\n\u003cp data-start=\"3466\" data-end=\"3539\"\u003eAlways verify wiring configuration and compatibility before installation.\u003c\/p\u003e\n\u003chr data-start=\"3541\" data-end=\"3544\"\u003e\n\u003ch2 data-section-id=\"8fimbm\" data-start=\"3546\" data-end=\"3576\"\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul data-start=\"3578\" data-end=\"3915\"\u003e\n\u003cli data-section-id=\"1hm3vrn\" data-start=\"3578\" data-end=\"3632\"\u003eInspect wiring and electrical connections regularly.\u003c\/li\u003e\n\u003cli data-section-id=\"1di1ke4\" data-start=\"3633\" data-end=\"3693\"\u003eVerify proper switch operation during routine maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"omkja9\" data-start=\"3694\" data-end=\"3742\"\u003eCheck for corrosion, wear, or physical damage.\u003c\/li\u003e\n\u003cli data-section-id=\"1dognep\" data-start=\"3743\" data-end=\"3800\"\u003eEnsure pressure activation matches system requirements.\u003c\/li\u003e\n\u003cli data-section-id=\"iudf6w\" data-start=\"3801\" data-end=\"3857\"\u003eFollow equipment manufacturer installation procedures.\u003c\/li\u003e\n\u003cli data-section-id=\"rex0ca\" data-start=\"3858\" data-end=\"3915\"\u003eReplace damaged or malfunctioning switches immediately.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pressure Systems Innovations","offers":[{"title":"Default Title","offer_id":53339161133419,"sku":null,"price":38.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/6249PressureSwitch.webp?v=1780498640","url":"https:\/\/generalsprayers.com\/products\/mtm-pressure-switch-1-4-mpt-15-amp-360-psi-oem-replacement-part","provider":"GeneralSprayers","version":"1.0","type":"link"}