{"product_id":"gp-pulsar4khpez-unloader-valve-ez-start-up-to-10-5-gpm-up-to-4500-psi","title":"GP PULSAR4KHPEZ Unloader Valve – EZ Start, Up to 10.5 GPM, Up to 4500 PSI","description":"\u003cp data-start=\"139\" data-end=\"329\"\u003e\u003cstrong data-start=\"139\" data-end=\"149\"\u003eModel:\u003c\/strong\u003e PULSAR4KHPEZ\u003cbr data-start=\"162\" data-end=\"165\"\u003e\u003cstrong data-start=\"165\" data-end=\"178\"\u003eCategory:\u003c\/strong\u003e Pumps → Pump Accessories → Unloaders \/ Regulators\u003cbr data-start=\"228\" data-end=\"231\"\u003e\u003cstrong data-start=\"231\" data-end=\"240\"\u003eType:\u003c\/strong\u003e EZ Start Pressure Unloader Valve – High-Flow \/ High-Pressure, Genuine OEM General Pump\u003c\/p\u003e\n\u003chr data-start=\"331\" data-end=\"334\"\u003e\n\u003cp data-start=\"336\" data-end=\"764\"\u003eThe \u003cstrong data-start=\"340\" data-end=\"374\"\u003eGP PULSAR4KHPEZ Unloader Valve\u003c\/strong\u003e is a \u003cstrong data-start=\"380\" data-end=\"460\"\u003egenuine OEM \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eGeneral Pump\u003c\/span\u003e\u003c\/span\u003e EZ-Start pressure unloader\u003c\/strong\u003e engineered for \u003cstrong data-start=\"476\" data-end=\"520\"\u003ehigh-performance pressure washer systems\u003c\/strong\u003e that demand easier startups, reduced pressure loss, and reliable long-term operation. Featuring an \u003cstrong data-start=\"620\" data-end=\"639\"\u003eEZ Start design\u003c\/strong\u003e, this unloader facilitates water discharge during startup, reducing engine load and the energy required to start the system.\u003c\/p\u003e\n\u003chr data-start=\"1046\" data-end=\"1049\"\u003e\n\u003ch3 data-start=\"1051\" data-end=\"1071\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1072\" data-end=\"1391\"\u003e\n\u003cli data-start=\"1072\" data-end=\"1105\"\u003e\n\u003cp data-start=\"1074\" data-end=\"1105\"\u003e\u003cstrong data-start=\"1074\" data-end=\"1088\"\u003eFlow Rate:\u003c\/strong\u003e Up to 10.5 GPM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1106\" data-end=\"1138\"\u003e\n\u003cp data-start=\"1108\" data-end=\"1138\"\u003e\u003cstrong data-start=\"1108\" data-end=\"1127\"\u003eRated Pressure:\u003c\/strong\u003e 4050 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1139\" data-end=\"1173\"\u003e\n\u003cp data-start=\"1141\" data-end=\"1173\"\u003e\u003cstrong data-start=\"1141\" data-end=\"1162\"\u003eMaximum Pressure:\u003c\/strong\u003e 4500 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1174\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1176\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1176\" data-end=\"1200\"\u003eMaximum Temperature:\u003c\/strong\u003e 195°F\u003cbr data-start=\"1206\" data-end=\"1209\"\u003e\u003cem data-start=\"1211\" data-end=\"1250\"\u003e(Continuous use recommended at 140°F)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1289\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1289\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1271\"\u003eInlet Ports:\u003c\/strong\u003e (2) × 3\/8″ FNPT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1290\" data-end=\"1329\"\u003e\n\u003cp data-start=\"1292\" data-end=\"1329\"\u003e\u003cstrong data-start=\"1292\" data-end=\"1311\"\u003eDischarge Port:\u003c\/strong\u003e (1) × 3\/8″ FNPT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1330\" data-end=\"1367\"\u003e\n\u003cp data-start=\"1332\" data-end=\"1367\"\u003e\u003cstrong data-start=\"1332\" data-end=\"1349\"\u003eBypass Ports:\u003c\/strong\u003e (2) × 3\/8″ FNPT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1368\" data-end=\"1391\"\u003e\n\u003cp data-start=\"1370\" data-end=\"1391\"\u003e\u003cstrong data-start=\"1370\" data-end=\"1381\"\u003eWeight:\u003c\/strong\u003e 1.5 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1393\" data-end=\"1396\"\u003e\n\u003ch3 data-start=\"1398\" data-end=\"1412\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1413\" data-end=\"1768\"\u003e\n\u003cli data-start=\"1413\" data-end=\"1464\"\u003e\n\u003cp data-start=\"1415\" data-end=\"1464\"\u003e\u003cstrong data-start=\"1415\" data-end=\"1441\"\u003eEZ Start functionality\u003c\/strong\u003e reduces startup load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1465\" data-end=\"1521\"\u003e\n\u003cp data-start=\"1467\" data-end=\"1521\"\u003eFacilitates pressure discharge during engine startup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1522\" data-end=\"1576\"\u003e\n\u003cp data-start=\"1524\" data-end=\"1576\"\u003e\u003cstrong data-start=\"1524\" data-end=\"1547\"\u003eNew improved design\u003c\/strong\u003e with reduced pressure loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1577\" data-end=\"1615\"\u003e\n\u003cp data-start=\"1579\" data-end=\"1615\"\u003eMakes for \u003cstrong data-start=\"1589\" data-end=\"1613\"\u003eeasier gun operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1616\" data-end=\"1659\"\u003e\n\u003cp data-start=\"1618\" data-end=\"1659\"\u003eExtremely reliable for professional use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1660\" data-end=\"1694\"\u003e\n\u003cp data-start=\"1662\" data-end=\"1694\"\u003eEasy maintenance and servicing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1695\" data-end=\"1768\"\u003e\n\u003cp data-start=\"1697\" data-end=\"1768\"\u003eIncludes \u003cstrong data-start=\"1706\" data-end=\"1738\"\u003eadjustment knob with locknut\u003c\/strong\u003e for secure pressure setting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1770\" data-end=\"1773\"\u003e\n\u003ch3 data-start=\"1775\" data-end=\"1796\"\u003eProduct Details\u003c\/h3\u003e\n\u003cp data-start=\"1797\" data-end=\"1970\"\u003e\u003cstrong data-start=\"1797\" data-end=\"1807\"\u003eBrand:\u003c\/strong\u003e General Pump\u003cbr data-start=\"1820\" data-end=\"1823\"\u003e\u003cstrong data-start=\"1823\" data-end=\"1831\"\u003eOEM:\u003c\/strong\u003e Yes – Genuine General Pump Part\u003cbr data-start=\"1863\" data-end=\"1866\"\u003e\u003cstrong data-start=\"1866\" data-end=\"1882\"\u003eApplication:\u003c\/strong\u003e Pressure Regulation \/ Pump Protection\u003cbr data-start=\"1920\" data-end=\"1923\"\u003e\u003cstrong data-start=\"1923\" data-end=\"1941\"\u003eUnloader Type:\u003c\/strong\u003e EZ Start Pressure Unloader\u003c\/p\u003e\n\u003chr data-start=\"1972\" data-end=\"1975\"\u003e\n\u003ch3 data-start=\"1977\" data-end=\"1995\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul data-start=\"1996\" data-end=\"2224\"\u003e\n\u003cli data-start=\"1996\" data-end=\"2035\"\u003e\n\u003cp data-start=\"1998\" data-end=\"2035\"\u003eReduces energy required for startup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2036\" data-end=\"2075\"\u003e\n\u003cp data-start=\"2038\" data-end=\"2075\"\u003eProtects pump and system components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2076\" data-end=\"2119\"\u003e\n\u003cp data-start=\"2078\" data-end=\"2119\"\u003eMaintains consistent operating pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2120\" data-end=\"2169\"\u003e\n\u003cp data-start=\"2122\" data-end=\"2169\"\u003eDesigned for high-flow, high-pressure systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2170\" data-end=\"2224\"\u003e\n\u003cp data-start=\"2172\" data-end=\"2224\"\u003eDirect OEM replacement — no modifications required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Pump","offers":[{"title":"Default Title","offer_id":52880869949803,"sku":"PULSAR4KHPEZ","price":67.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/PULSAR4KHPEZ.jpg?v=1770130451","url":"https:\/\/generalsprayers.com\/products\/gp-pulsar4khpez-unloader-valve-ez-start-up-to-10-5-gpm-up-to-4500-psi","provider":"GeneralSprayers","version":"1.0","type":"link"}