{"product_id":"gp-100534-safety-relief-valve-pre-set-to-4600-psi","title":"GP 100534 Safety Relief Valve – Pre-Set to 4600 PSI","description":"\u003cp data-start=\"124\" data-end=\"296\"\u003e\u003cstrong data-start=\"124\" data-end=\"134\"\u003eModel:\u003c\/strong\u003e 100534\u003cbr data-start=\"141\" data-end=\"144\"\u003e\u003cstrong data-start=\"144\" data-end=\"157\"\u003eCategory:\u003c\/strong\u003e Pumps → Pump Accessories → Safety Valves \/ Relief Valves\u003cbr data-start=\"214\" data-end=\"217\"\u003e\u003cstrong data-start=\"217\" data-end=\"226\"\u003eType:\u003c\/strong\u003e Safety Relief Valve – Pre-Set to 4600 PSI, Genuine OEM General Pump\u003c\/p\u003e\n\u003chr data-start=\"298\" data-end=\"301\"\u003e\n\u003cp data-start=\"303\" data-end=\"668\"\u003eThe \u003cstrong data-start=\"307\" data-end=\"340\"\u003eGP 100534 Safety Relief Valve\u003c\/strong\u003e is a \u003cstrong data-start=\"346\" data-end=\"430\"\u003egenuine OEM \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eGeneral Pump\u003c\/span\u003e\u003c\/span\u003e over-pressure protection valve\u003c\/strong\u003e designed to safeguard pumps, hoses, and system components from \u003cstrong data-start=\"494\" data-end=\"523\"\u003edangerous pressure spikes\u003c\/strong\u003e. Factory \u003cstrong data-start=\"533\" data-end=\"556\"\u003epre-set to 4600 PSI\u003c\/strong\u003e, this valve opens automatically when pressure exceeds safe limits, providing fast and reliable pressure relief.\u003c\/p\u003e\n\u003chr data-start=\"1018\" data-end=\"1021\"\u003e\n\u003ch3 data-start=\"1023\" data-end=\"1041\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1042\" data-end=\"1297\"\u003e\n\u003cli data-start=\"1042\" data-end=\"1114\"\u003e\n\u003cp data-start=\"1044\" data-end=\"1114\"\u003ePressure washer systems requiring secondary over-pressure protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1115\" data-end=\"1182\"\u003e\n\u003cp data-start=\"1117\" data-end=\"1182\"\u003eInstallations using unloaders where added safety is recommended\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1183\" data-end=\"1243\"\u003e\n\u003cp data-start=\"1185\" data-end=\"1243\"\u003eSystems subject to pressure spikes or flow interruptions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1244\" data-end=\"1297\"\u003e\n\u003cp data-start=\"1246\" data-end=\"1297\"\u003eCommercial and industrial pressure washing setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1299\" data-end=\"1302\"\u003e\n\u003ch3 data-start=\"1304\" data-end=\"1324\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1325\" data-end=\"1554\"\u003e\n\u003cli data-start=\"1325\" data-end=\"1375\"\u003e\n\u003cp data-start=\"1327\" data-end=\"1375\"\u003e\u003cstrong data-start=\"1327\" data-end=\"1346\"\u003eRelief Setting:\u003c\/strong\u003e 4600 PSI (factory pre-set)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1376\" data-end=\"1410\"\u003e\n\u003cp data-start=\"1378\" data-end=\"1410\"\u003e\u003cstrong data-start=\"1378\" data-end=\"1399\"\u003eMaximum Pressure:\u003c\/strong\u003e 6000 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1411\" data-end=\"1445\"\u003e\n\u003cp data-start=\"1413\" data-end=\"1445\"\u003e\u003cstrong data-start=\"1413\" data-end=\"1434\"\u003eMinimum Pressure:\u003c\/strong\u003e 2000 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1446\" data-end=\"1473\"\u003e\n\u003cp data-start=\"1448\" data-end=\"1473\"\u003e\u003cstrong data-start=\"1448\" data-end=\"1465\"\u003eMaximum Flow:\u003c\/strong\u003e 6 GPM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1474\" data-end=\"1508\"\u003e\n\u003cp data-start=\"1476\" data-end=\"1508\"\u003e\u003cstrong data-start=\"1476\" data-end=\"1500\"\u003eMaximum Temperature:\u003c\/strong\u003e 195°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1509\" data-end=\"1534\"\u003e\n\u003cp data-start=\"1511\" data-end=\"1534\"\u003e\u003cstrong data-start=\"1511\" data-end=\"1521\"\u003eInlet:\u003c\/strong\u003e 3\/8″ NPT-M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1535\" data-end=\"1554\"\u003e\n\u003cp data-start=\"1537\" data-end=\"1554\"\u003e\u003cstrong data-start=\"1537\" data-end=\"1548\"\u003eOutlet:\u003c\/strong\u003e End\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1556\" data-end=\"1559\"\u003e\n\u003ch3 data-start=\"1561\" data-end=\"1582\"\u003eProduct Details\u003c\/h3\u003e\n\u003cp data-start=\"1583\" data-end=\"1749\"\u003e\u003cstrong data-start=\"1583\" data-end=\"1593\"\u003eBrand:\u003c\/strong\u003e General Pump\u003cbr data-start=\"1606\" data-end=\"1609\"\u003e\u003cstrong data-start=\"1609\" data-end=\"1617\"\u003eOEM:\u003c\/strong\u003e Yes – Genuine General Pump Part\u003cbr data-start=\"1649\" data-end=\"1652\"\u003e\u003cstrong data-start=\"1652\" data-end=\"1668\"\u003eApplication:\u003c\/strong\u003e Over-Pressure Protection \/ Safety Relief\u003cbr data-start=\"1709\" data-end=\"1712\"\u003e\u003cstrong data-start=\"1712\" data-end=\"1727\"\u003eValve Type:\u003c\/strong\u003e Safety Relief Valve\u003c\/p\u003e\n\u003chr data-start=\"1751\" data-end=\"1754\"\u003e\n\u003ch3 data-start=\"1756\" data-end=\"1774\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1775\" data-end=\"2234\"\u003e\n\u003cli data-start=\"1775\" data-end=\"1834\"\u003e\n\u003cp data-start=\"1777\" data-end=\"1834\"\u003eGenuine OEM \u003cstrong data-start=\"1789\" data-end=\"1812\"\u003eGeneral Pump 100534\u003c\/strong\u003e safety relief valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1835\" data-end=\"1897\"\u003e\n\u003cp data-start=\"1837\" data-end=\"1897\"\u003e\u003cstrong data-start=\"1837\" data-end=\"1860\"\u003ePre-set to 4600 PSI\u003c\/strong\u003e for dependable pressure protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1898\" data-end=\"1963\"\u003e\n\u003cp data-start=\"1900\" data-end=\"1963\"\u003e\u003cstrong data-start=\"1900\" data-end=\"1932\"\u003eOne model fits all pressures\u003c\/strong\u003e — no spring changes required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1964\" data-end=\"2005\"\u003e\n\u003cp data-start=\"1966\" data-end=\"2005\"\u003eCompatible with \u003cstrong data-start=\"1982\" data-end=\"2003\"\u003eany brand of pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2006\" data-end=\"2048\"\u003e\n\u003cp data-start=\"2008\" data-end=\"2048\"\u003eRated for \u003cstrong data-start=\"2018\" data-end=\"2046\"\u003eup to 6000 PSI and 6 GPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2049\" data-end=\"2107\"\u003e\n\u003cp data-start=\"2051\" data-end=\"2107\"\u003e\u003cstrong data-start=\"2051\" data-end=\"2084\"\u003eReduced whistling and chatter\u003c\/strong\u003e vs. competing valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2108\" data-end=\"2158\"\u003e\n\u003cp data-start=\"2110\" data-end=\"2158\"\u003eHighly accurate across the full pressure range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2159\" data-end=\"2195\"\u003e\n\u003cp data-start=\"2161\" data-end=\"2195\"\u003e\u003cstrong data-start=\"2161\" data-end=\"2193\"\u003eDesigned and made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2196\" data-end=\"2234\"\u003e\n\u003cp data-start=\"2198\" data-end=\"2234\"\u003eLong-life, heavy-duty construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Pump","offers":[{"title":"Default Title","offer_id":52881836310891,"sku":"100534","price":24.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/100534.jpg?v=1770155007","url":"https:\/\/generalsprayers.com\/products\/gp-100534-safety-relief-valve-pre-set-to-4600-psi","provider":"GeneralSprayers","version":"1.0","type":"link"}