{"product_id":"general-pump-12v-variable-speed-rewind-controller-for-gp-a-frame-hose-reels","title":"General Pump 12V Variable Speed Rewind Controller – For GP A-Frame Hose Reels","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-6a4a8cf5-f650-83ea-96f8-2b527155fa10-44\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a4a8cf5-f650-83ea-96f8-2b527155fa10-44\" data-turn-id-container=\"request-6a4a8cf5-f650-83ea-96f8-2b527155fa10-44\" data-testid=\"conversation-turn-178\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"840d5676-7dd3-48c7-a2b4-87af54addf9a\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"0\" data-end=\"173\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong data-start=\"0\" data-end=\"16\"\u003ePart Number:\u003c\/strong\u003e 7258\u003cbr data-start=\"21\" data-end=\"24\"\u003e\u003cstrong data-start=\"24\" data-end=\"37\"\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Hose Reel Accessories\u003cbr data-start=\"83\" data-end=\"86\"\u003e\u003cstrong data-start=\"86\" data-end=\"95\"\u003eType:\u003c\/strong\u003e General Pump 12V Variable Speed Rewind Controller – For GP A-Frame Hose Reels\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"175\" data-end=\"178\"\u003e\n\u003cp data-start=\"261\" data-end=\"700\"\u003eThe \u003cstrong data-start=\"265\" data-end=\"331\"\u003eGeneral Pump 12V Variable Speed Rewind Controller (Part #7258)\u003c\/strong\u003e is a genuine OEM control module designed to provide smooth, adjustable electric rewind operation for compatible \u003cstrong data-start=\"444\" data-end=\"479\"\u003eGeneral Pump A-frame hose reels\u003c\/strong\u003e. Powered by a \u003cstrong data-start=\"494\" data-end=\"515\"\u003e12-volt DC system\u003c\/strong\u003e, this heavy-duty controller allows operators to precisely control hose rewind speed, improving safety, reducing hose wear, and increasing efficiency during pressure washing operations.\u003c\/p\u003e\n\u003chr data-start=\"1528\" data-end=\"1531\"\u003e\n\u003ch2 data-section-id=\"939trr\" data-start=\"1533\" data-end=\"1559\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1561\" data-end=\"2105\"\u003e\n\u003cli data-section-id=\"11izaqt\" data-start=\"1561\" data-end=\"1605\"\u003eGenuine General Pump OEM rewind controller\u003c\/li\u003e\n\u003cli data-section-id=\"1yilgz2\" data-start=\"1606\" data-end=\"1629\"\u003e\n\u003cstrong data-start=\"1608\" data-end=\"1624\"\u003ePart Number:\u003c\/strong\u003e 7258\u003c\/li\u003e\n\u003cli data-section-id=\"1ejl55x\" data-start=\"1630\" data-end=\"1687\"\u003eDesigned for compatible General Pump A-frame hose reels\u003c\/li\u003e\n\u003cli data-section-id=\"7fcc5\" data-start=\"1688\" data-end=\"1710\"\u003e12-volt DC operation\u003c\/li\u003e\n\u003cli data-section-id=\"er9zvx\" data-start=\"1711\" data-end=\"1742\"\u003eVariable speed rewind control\u003c\/li\u003e\n\u003cli data-section-id=\"1ou2mhz\" data-start=\"1743\" data-end=\"1794\"\u003eVariable speed knob with integrated on\/off switch\u003c\/li\u003e\n\u003cli data-section-id=\"1lybbkj\" data-start=\"1795\" data-end=\"1831\"\u003eHeavy-duty momentary on\/off switch\u003c\/li\u003e\n\u003cli data-section-id=\"7ikb2u\" data-start=\"1832\" data-end=\"1867\"\u003e30-amp auto-reset circuit breaker\u003c\/li\u003e\n\u003cli data-section-id=\"138nszp\" data-start=\"1868\" data-end=\"1895\"\u003eLED power indicator light\u003c\/li\u003e\n\u003cli data-section-id=\"crjh1z\" data-start=\"1896\" data-end=\"1930\"\u003eSealed weather-resistant housing\u003c\/li\u003e\n\u003cli data-section-id=\"fqvn3k\" data-start=\"1931\" data-end=\"1972\"\u003eRight- or left-hand mounting capability\u003c\/li\u003e\n\u003cli data-section-id=\"v6bqya\" data-start=\"1973\" data-end=\"2018\"\u003eImproves rewind control and operator safety\u003c\/li\u003e\n\u003cli data-section-id=\"1aewd0a\" data-start=\"2019\" data-end=\"2057\"\u003eHelps reduce hose wear during rewind\u003c\/li\u003e\n\u003cli data-section-id=\"19l060k\" data-start=\"2058\" data-end=\"2105\"\u003eIdeal for commercial pressure washing systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2107\" data-end=\"2110\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"2112\" data-end=\"2139\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"2141\" data-end=\"2162\"\u003e\u003cstrong data-start=\"2141\" data-end=\"2157\"\u003ePart Number:\u003c\/strong\u003e 7258\u003c\/p\u003e\n\u003cp data-start=\"2164\" data-end=\"2194\"\u003e\u003cstrong data-start=\"2164\" data-end=\"2181\"\u003eManufacturer:\u003c\/strong\u003e General Pump\u003c\/p\u003e\n\u003cp data-start=\"2196\" data-end=\"2250\"\u003e\u003cstrong data-start=\"2196\" data-end=\"2213\"\u003eProduct Type:\u003c\/strong\u003e Electric Hose Reel Rewind Controller\u003c\/p\u003e\n\u003cp data-start=\"2252\" data-end=\"2271\"\u003e\u003cstrong data-start=\"2252\" data-end=\"2264\"\u003eVoltage:\u003c\/strong\u003e 12V DC\u003c\/p\u003e\n\u003cp data-start=\"2273\" data-end=\"2306\"\u003e\u003cstrong data-start=\"2273\" data-end=\"2291\"\u003eSpeed Control:\u003c\/strong\u003e Variable Speed\u003c\/p\u003e\n\u003cp data-start=\"2308\" data-end=\"2355\"\u003e\u003cstrong data-start=\"2308\" data-end=\"2327\"\u003eControl Switch:\u003c\/strong\u003e Heavy-Duty Momentary On\/Off\u003c\/p\u003e\n\u003cp data-start=\"2357\" data-end=\"2421\"\u003e\u003cstrong data-start=\"2357\" data-end=\"2378\"\u003eSpeed Adjustment:\u003c\/strong\u003e Variable Speed Knob with Integrated On\/Off\u003c\/p\u003e\n\u003cp data-start=\"2423\" data-end=\"2480\"\u003e\u003cstrong data-start=\"2423\" data-end=\"2446\"\u003eCircuit Protection:\u003c\/strong\u003e 30 Amp Auto-Reset Circuit Breaker\u003c\/p\u003e\n\u003cp data-start=\"2482\" data-end=\"2506\"\u003e\u003cstrong data-start=\"2482\" data-end=\"2502\"\u003ePower Indicator:\u003c\/strong\u003e LED\u003c\/p\u003e\n\u003cp data-start=\"2508\" data-end=\"2555\"\u003e\u003cstrong data-start=\"2508\" data-end=\"2520\"\u003eHousing:\u003c\/strong\u003e Sealed Weather-Resistant Enclosure\u003c\/p\u003e\n\u003cp data-start=\"2557\" data-end=\"2602\"\u003e\u003cstrong data-start=\"2557\" data-end=\"2582\"\u003eMounting Orientation:\u003c\/strong\u003e Right- or Left-Hand\u003c\/p\u003e\n\u003cp data-start=\"2604\" data-end=\"2628\"\u003e\u003cstrong data-start=\"2604\" data-end=\"2624\"\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr data-start=\"2630\" data-end=\"2633\"\u003e\n\u003ch2 data-section-id=\"17z2fqi\" data-start=\"2635\" data-end=\"2661\"\u003eCompatible Applications\u003c\/h2\u003e\n\u003cp data-start=\"2663\" data-end=\"2685\"\u003eSuitable for use with:\u003c\/p\u003e\n\u003cul data-start=\"2687\" data-end=\"2997\"\u003e\n\u003cli data-section-id=\"1lwznm3\" data-start=\"2687\" data-end=\"2720\"\u003eGeneral Pump A-frame hose reels\u003c\/li\u003e\n\u003cli data-section-id=\"1yni5o1\" data-start=\"2721\" data-end=\"2756\"\u003eElectric rewind hose reel systems\u003c\/li\u003e\n\u003cli data-section-id=\"jhf7om\" data-start=\"2757\" data-end=\"2784\"\u003ePressure washing trailers\u003c\/li\u003e\n\u003cli data-section-id=\"1cxzls8\" data-start=\"2785\" data-end=\"2810\"\u003ePressure washing trucks\u003c\/li\u003e\n\u003cli data-section-id=\"1ftw8hk\" data-start=\"2811\" data-end=\"2840\"\u003eCommercial pressure washers\u003c\/li\u003e\n\u003cli data-section-id=\"e9p5qp\" data-start=\"2841\" data-end=\"2878\"\u003eIndustrial pressure washing systems\u003c\/li\u003e\n\u003cli data-section-id=\"1mv9afl\" data-start=\"2879\" data-end=\"2904\"\u003eFleet washing equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1jcdcam\" data-start=\"2905\" data-end=\"2938\"\u003eAgricultural cleaning equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1mvc186\" data-start=\"2939\" data-end=\"2971\"\u003eMunicipal maintenance vehicles\u003c\/li\u003e\n\u003cli data-section-id=\"5lusce\" data-start=\"2972\" data-end=\"2997\"\u003eMobile service vehicles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2999\" data-end=\"3094\"\u003eAlways verify controller compatibility, operating voltage, and hose reel model before ordering.\u003c\/p\u003e\n\u003chr data-start=\"3096\" data-end=\"3099\"\u003e\n\u003ch2 data-section-id=\"1m26y2w\" data-start=\"3101\" data-end=\"3137\"\u003eFunction of the Rewind Controller\u003c\/h2\u003e\n\u003cp data-start=\"3139\" data-end=\"3197\"\u003eThe \u003cstrong data-start=\"3143\" data-end=\"3190\"\u003eGeneral Pump 7258 Variable Speed Controller\u003c\/strong\u003e helps:\u003c\/p\u003e\n\u003cul data-start=\"3199\" data-end=\"3463\"\u003e\n\u003cli data-section-id=\"1wj6p3\" data-start=\"3199\" data-end=\"3240\"\u003eControl electric hose reel rewind speed\u003c\/li\u003e\n\u003cli data-section-id=\"yudrxx\" data-start=\"3241\" data-end=\"3284\"\u003eProvide smooth, adjustable hose retrieval\u003c\/li\u003e\n\u003cli data-section-id=\"8rk879\" data-start=\"3285\" data-end=\"3318\"\u003eReduce hose shock during rewind\u003c\/li\u003e\n\u003cli data-section-id=\"sa3xgi\" data-start=\"3319\" data-end=\"3356\"\u003eImprove operator control and safety\u003c\/li\u003e\n\u003cli data-section-id=\"nn12yc\" data-start=\"3357\" data-end=\"3423\"\u003eProtect electrical components with integrated circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"r2b5bg\" data-start=\"3424\" data-end=\"3463\"\u003eSimplify electric hose reel operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3465\" data-end=\"3647\"\u003eIts variable speed functionality allows operators to rewind hoses at the appropriate speed for different working conditions while minimizing hose stress and extending equipment life.\u003c\/p\u003e\n\u003chr data-start=\"3649\" data-end=\"3652\"\u003e\n\u003ch2 data-section-id=\"1cnbljb\" data-start=\"3654\" data-end=\"3691\"\u003eCommon Signs Replacement Is Needed\u003c\/h2\u003e\n\u003cp data-start=\"3693\" data-end=\"3730\"\u003eReplace the controller if you notice:\u003c\/p\u003e\n\u003cul data-start=\"3732\" data-end=\"3995\"\u003e\n\u003cli data-section-id=\"1h9xf8k\" data-start=\"3732\" data-end=\"3764\"\u003eLoss of variable speed control\u003c\/li\u003e\n\u003cli data-section-id=\"137pg1s\" data-start=\"3765\" data-end=\"3795\"\u003eController fails to power on\u003c\/li\u003e\n\u003cli data-section-id=\"1urglna\" data-start=\"3796\" data-end=\"3837\"\u003eLED power indicator no longer functions\u003c\/li\u003e\n\u003cli data-section-id=\"1qgpkpw\" data-start=\"3838\" data-end=\"3864\"\u003eDamaged control switches\u003c\/li\u003e\n\u003cli data-section-id=\"1ajrsq5\" data-start=\"3865\" data-end=\"3902\"\u003eMoisture intrusion into the housing\u003c\/li\u003e\n\u003cli data-section-id=\"xseoe1\" data-start=\"3903\" data-end=\"3950\"\u003eElectrical overload or intermittent operation\u003c\/li\u003e\n\u003cli data-section-id=\"1kfv6lb\" data-start=\"3951\" data-end=\"3995\"\u003ePhysical damage to the enclosure or wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3997\" data-end=\"4080\"\u003eReplacing a faulty controller restores safe, reliable electric hose reel operation.\u003c\/p\u003e\n\u003chr data-start=\"4082\" data-end=\"4085\"\u003e\n\u003ch2 data-section-id=\"10va281\" data-start=\"4087\" data-end=\"4118\"\u003eInstallation \u0026amp; Service Notes\u003c\/h2\u003e\n\u003cp data-start=\"4120\" data-end=\"4157\"\u003eDisconnect power before installation.\u003c\/p\u003e\n\u003cp data-start=\"4159\" data-end=\"4279\"\u003eMount the controller using either the \u003cstrong data-start=\"4197\" data-end=\"4247\"\u003eright-hand or left-hand mounting configuration\u003c\/strong\u003e as required for your equipment.\u003c\/p\u003e\n\u003cp data-start=\"4281\" data-end=\"4393\"\u003eConnect the controller to a compatible \u003cstrong data-start=\"4320\" data-end=\"4343\"\u003e12V DC power source\u003c\/strong\u003e following the manufacturer's wiring instructions.\u003c\/p\u003e\n\u003cp data-start=\"4395\" data-end=\"4463\"\u003eVerify all electrical connections are secure before restoring power.\u003c\/p\u003e\n\u003cp data-start=\"4465\" data-end=\"4594\"\u003eTest the \u003cstrong data-start=\"4474\" data-end=\"4500\"\u003evariable speed control\u003c\/strong\u003e, \u003cstrong data-start=\"4502\" data-end=\"4522\"\u003emomentary switch\u003c\/strong\u003e, and \u003cstrong data-start=\"4528\" data-end=\"4551\"\u003eLED power indicator\u003c\/strong\u003e before placing the hose reel into service.\u003c\/p\u003e\n\u003cp data-start=\"4596\" data-end=\"4806\"\u003e\u003cstrong data-start=\"4596\" data-end=\"4610\"\u003eImportant:\u003c\/strong\u003e Always use appropriate wire sizing, fuse protection, and electrical connections when installing 12V equipment. Verify compatibility with your General Pump A-frame hose reel prior to installation.\u003c\/p\u003e\n\u003chr data-start=\"4808\" data-end=\"4811\"\u003e\n\u003ch2 data-section-id=\"8fimbm\" data-start=\"4813\" data-end=\"4843\"\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul data-start=\"4845\" data-end=\"5295\"\u003e\n\u003cli data-section-id=\"1cjcake\" data-start=\"4845\" data-end=\"4919\"\u003eInspect electrical wiring and terminals regularly for wear or corrosion.\u003c\/li\u003e\n\u003cli data-section-id=\"1ok1cev\" data-start=\"4920\" data-end=\"4983\"\u003eKeep the controller housing clean and free of dirt or debris.\u003c\/li\u003e\n\u003cli data-section-id=\"1osomhd\" data-start=\"4984\" data-end=\"5045\"\u003eCheck switch operation periodically for smooth performance.\u003c\/li\u003e\n\u003cli data-section-id=\"1aswzi3\" data-start=\"5046\" data-end=\"5098\"\u003eVerify the LED power indicator operates correctly.\u003c\/li\u003e\n\u003cli data-section-id=\"1bj7uc5\" data-start=\"5099\" data-end=\"5168\"\u003eInspect mounting hardware for tightness during routine maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"aahxv1\" data-start=\"5169\" data-end=\"5295\"\u003eUse only genuine OEM General Pump replacement components to maintain safe operation, reliability, and long-term performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"General Pump","offers":[{"title":"Default Title","offer_id":53466921632107,"sku":null,"price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/725812VSPEEDCONTROLLER.webp?v=1783383537","url":"https:\/\/generalsprayers.com\/products\/general-pump-12v-variable-speed-rewind-controller-for-gp-a-frame-hose-reels","provider":"GeneralSprayers","version":"1.0","type":"link"}