{"product_id":"generac-0e6155-arm-extender-pin-genuine-oem-replacement-transfer-switch-arm-pin","title":"Generac 0E6155 Arm Extender Pin – Genuine OEM Replacement Transfer Switch Arm Pin","description":"\u003cp data-start=\"0\" data-end=\"219\"\u003e\u003cstrong data-start=\"0\" data-end=\"16\"\u003ePart Number:\u003c\/strong\u003e 0E6155\u003cbr data-start=\"23\" data-end=\"26\"\u003e\u003cstrong data-start=\"26\" data-end=\"39\"\u003eCategory:\u003c\/strong\u003e Generator Parts \u0026amp; Accessories → Transfer Switch Parts → Mechanical Linkage Components\u003cbr data-start=\"125\" data-end=\"128\"\u003e\u003cstrong data-start=\"128\" data-end=\"137\"\u003eType:\u003c\/strong\u003e Generac 0E6155 Arm Extender Pin – Genuine OEM Replacement Transfer Switch Arm Pin\u003c\/p\u003e\n\u003chr data-start=\"221\" data-end=\"224\"\u003e\n\u003cp data-start=\"226\" data-end=\"741\"\u003eThe Generac 0E6155 Arm Extender Pin is a genuine OEM replacement mechanical linkage component designed for compatible Generac transfer switch assemblies. This pin helps connect, position, or retain the designated arm extender mechanism so the transfer switch linkage can move and operate correctly. Manufactured to original equipment specifications, it provides a direct replacement for a missing, worn, bent, or damaged arm pin while supporting proper mechanical alignment and dependable transfer switch operation.\u003c\/p\u003e\n\u003chr data-start=\"743\" data-end=\"746\"\u003e\n\u003ch2 data-section-id=\"1pi78xj\" data-start=\"748\" data-end=\"778\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"751\" data-end=\"778\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"780\" data-end=\"1385\"\u003e\n\u003cli data-section-id=\"606kl0\" data-start=\"780\" data-end=\"801\"\u003ePart Number: 0E6155\u003c\/li\u003e\n\u003cli data-section-id=\"1n1ya84\" data-start=\"802\" data-end=\"840\"\u003eGenuine OEM Generac replacement part\u003c\/li\u003e\n\u003cli data-section-id=\"p9b3y6\" data-start=\"841\" data-end=\"901\"\u003eDesigned for compatible Generac transfer switch assemblies\u003c\/li\u003e\n\u003cli data-section-id=\"4864uv\" data-start=\"902\" data-end=\"950\"\u003eReplacement pin for the arm extender mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"2r4vmr\" data-start=\"951\" data-end=\"1007\"\u003eHelps connect and retain designated linkage components\u003c\/li\u003e\n\u003cli data-section-id=\"uxtns2\" data-start=\"1008\" data-end=\"1059\"\u003eSupports proper mechanical movement and alignment\u003c\/li\u003e\n\u003cli data-section-id=\"3tmk30\" data-start=\"1060\" data-end=\"1111\"\u003eHelps maintain reliable transfer switch actuation\u003c\/li\u003e\n\u003cli data-section-id=\"sx8xth\" data-start=\"1112\" data-end=\"1174\"\u003eDirect replacement for a worn, missing, bent, or damaged pin\u003c\/li\u003e\n\u003cli data-section-id=\"fyhvnz\" data-start=\"1175\" data-end=\"1226\"\u003eManufactured to original equipment specifications\u003c\/li\u003e\n\u003cli data-section-id=\"1dfmnda\" data-start=\"1227\" data-end=\"1272\"\u003eDurable construction for dependable service\u003c\/li\u003e\n\u003cli data-section-id=\"1ok5jqx\" data-start=\"1273\" data-end=\"1339\"\u003eSuitable for transfer switch repair and maintenance applications\u003c\/li\u003e\n\u003cli data-section-id=\"pzc2bd\" data-start=\"1340\" data-end=\"1385\"\u003eSold as an individual replacement component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1387\" data-end=\"1390\"\u003e\n\u003ch2 data-section-id=\"id1bjs\" data-start=\"1392\" data-end=\"1423\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1395\" data-end=\"1423\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1425\" data-end=\"1707\"\u003e\n\u003cli data-section-id=\"606kl0\" data-start=\"1425\" data-end=\"1446\"\u003ePart Number: 0E6155\u003c\/li\u003e\n\u003cli data-section-id=\"1419b18\" data-start=\"1447\" data-end=\"1470\"\u003eManufacturer: Generac\u003c\/li\u003e\n\u003cli data-section-id=\"1rymz21\" data-start=\"1471\" data-end=\"1503\"\u003eProduct Type: Arm Extender Pin\u003c\/li\u003e\n\u003cli data-section-id=\"1r0qfp6\" data-start=\"1504\" data-end=\"1544\"\u003eComponent Type: Mechanical Linkage Pin\u003c\/li\u003e\n\u003cli data-section-id=\"mujvq1\" data-start=\"1545\" data-end=\"1600\"\u003eApplication: Transfer switch arm and linkage assembly\u003c\/li\u003e\n\u003cli data-section-id=\"d5xwen\" data-start=\"1601\" data-end=\"1661\"\u003eFunction: Component connection, positioning, and retention\u003c\/li\u003e\n\u003cli data-section-id=\"t73psd\" data-start=\"1662\" data-end=\"1677\"\u003eOEM Part: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1ic2kyp\" data-start=\"1678\" data-end=\"1707\"\u003eQuantity: Sold Individually\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1709\" data-end=\"1712\"\u003e\n\u003ch2 data-section-id=\"4jtp2i\" data-start=\"1714\" data-end=\"1744\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1717\" data-end=\"1744\"\u003eCompatible Applications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1746\" data-end=\"1805\"\u003eThe Generac 0E6155 Arm Extender Pin is designed for select:\u003c\/p\u003e\n\u003cul data-start=\"1807\" data-end=\"2065\"\u003e\n\u003cli data-section-id=\"16y6wcj\" data-start=\"1807\" data-end=\"1844\"\u003eGenerac automatic transfer switches\u003c\/li\u003e\n\u003cli data-section-id=\"9wka4\" data-start=\"1845\" data-end=\"1892\"\u003eCompatible transfer switch linkage assemblies\u003c\/li\u003e\n\u003cli data-section-id=\"jkb2ir\" data-start=\"1893\" data-end=\"1935\"\u003eStandby generator power-transfer systems\u003c\/li\u003e\n\u003cli data-section-id=\"9ixcbz\" data-start=\"1936\" data-end=\"1961\"\u003eArm extender mechanisms\u003c\/li\u003e\n\u003cli data-section-id=\"hxylcj\" data-start=\"1962\" data-end=\"2015\"\u003eTransfer switch repair and maintenance applications\u003c\/li\u003e\n\u003cli data-section-id=\"2nmvhj\" data-start=\"2016\" data-end=\"2065\"\u003eEquipment requiring OEM arm extender pin 0E6155\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2067\" data-end=\"2261\"\u003eAlways verify the transfer switch model, serial number, amperage and configuration, installation location, parts diagram, and original part number before ordering to ensure proper compatibility.\u003c\/p\u003e\n\u003chr data-start=\"2263\" data-end=\"2266\"\u003e\n\u003ch2 data-section-id=\"8mx3gv\" data-start=\"2268\" data-end=\"2307\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2271\" data-end=\"2307\"\u003eFunction of the Arm Extender Pin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2309\" data-end=\"2352\"\u003eThe 0E6155 Arm Extender Pin is designed to:\u003c\/p\u003e\n\u003cul data-start=\"2354\" data-end=\"2786\"\u003e\n\u003cli data-section-id=\"1kcstsz\" data-start=\"2354\" data-end=\"2398\"\u003eConnect designated arm extender components\u003c\/li\u003e\n\u003cli data-section-id=\"nsupc\" data-start=\"2399\" data-end=\"2447\"\u003eRetain the transfer switch linkage in position\u003c\/li\u003e\n\u003cli data-section-id=\"1diei8e\" data-start=\"2448\" data-end=\"2501\"\u003eSupport proper movement of the mechanical mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1cju5by\" data-start=\"2502\" data-end=\"2556\"\u003eMaintain correct alignment between mating components\u003c\/li\u003e\n\u003cli data-section-id=\"1stenln\" data-start=\"2557\" data-end=\"2618\"\u003eHelp transfer mechanical force through the linkage assembly\u003c\/li\u003e\n\u003cli data-section-id=\"1uq4t7e\" data-start=\"2619\" data-end=\"2678\"\u003eReduce unwanted movement or separation of connected parts\u003c\/li\u003e\n\u003cli data-section-id=\"1dfm3w7\" data-start=\"2679\" data-end=\"2740\"\u003eRestore the original transfer switch hardware configuration\u003c\/li\u003e\n\u003cli data-section-id=\"18s5jfj\" data-start=\"2741\" data-end=\"2786\"\u003eSupport dependable power-transfer operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2788\" data-end=\"2924\"\u003eUsing the correct OEM pin helps maintain proper linkage geometry and reliable mechanical engagement within the transfer switch assembly.\u003c\/p\u003e\n\u003chr data-start=\"2926\" data-end=\"2929\"\u003e\n\u003ch2 data-section-id=\"1h7g79j\" data-start=\"2931\" data-end=\"2972\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2934\" data-end=\"2972\"\u003eCommon Signs Replacement Is Needed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2974\" data-end=\"3017\"\u003eReplace the arm extender pin if you notice:\u003c\/p\u003e\n\u003cul data-start=\"3019\" data-end=\"3413\"\u003e\n\u003cli data-section-id=\"1svgnap\" data-start=\"3019\" data-end=\"3045\"\u003eMissing linkage hardware\u003c\/li\u003e\n\u003cli data-section-id=\"1kplnfd\" data-start=\"3046\" data-end=\"3076\"\u003eBent, cracked, or broken pin\u003c\/li\u003e\n\u003cli data-section-id=\"tg7ef3\" data-start=\"3077\" data-end=\"3108\"\u003eExcessive wear or deformation\u003c\/li\u003e\n\u003cli data-section-id=\"ymxvkj\" data-start=\"3109\" data-end=\"3145\"\u003eCorrosion or surface deterioration\u003c\/li\u003e\n\u003cli data-section-id=\"16juh3q\" data-start=\"3146\" data-end=\"3182\"\u003eLoose or misaligned arm components\u003c\/li\u003e\n\u003cli data-section-id=\"zp3aq3\" data-start=\"3183\" data-end=\"3224\"\u003eExcessive play in the linkage mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"pvm9kj\" data-start=\"3225\" data-end=\"3273\"\u003eBinding or restricted transfer switch movement\u003c\/li\u003e\n\u003cli data-section-id=\"10tc02o\" data-start=\"3274\" data-end=\"3312\"\u003ePin repeatedly moves out of position\u003c\/li\u003e\n\u003cli data-section-id=\"rs27ys\" data-start=\"3313\" data-end=\"3359\"\u003eTransfer mechanism does not engage correctly\u003c\/li\u003e\n\u003cli data-section-id=\"2jda2d\" data-start=\"3360\" data-end=\"3413\"\u003eDamage discovered during transfer switch inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3415\" data-end=\"3555\"\u003eA worn or damaged pin may prevent the linkage from maintaining proper alignment and could interfere with reliable transfer switch operation.\u003c\/p\u003e\n\u003chr data-start=\"3557\" data-end=\"3560\"\u003e\n\u003ch2 data-section-id=\"bnihmp\" data-start=\"3562\" data-end=\"3597\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3565\" data-end=\"3597\"\u003eInstallation \u0026amp; Service Notes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"3599\" data-end=\"4428\"\u003e\n\u003cli data-section-id=\"1wpq4uw\" data-start=\"3599\" data-end=\"3671\"\u003ePlace the generator in the off position and disable automatic startup.\u003c\/li\u003e\n\u003cli data-section-id=\"1o58qy4\" data-start=\"3672\" data-end=\"3749\"\u003eIsolate all utility, generator, and control-power sources before servicing.\u003c\/li\u003e\n\u003cli data-section-id=\"1tio5jm\" data-start=\"3750\" data-end=\"3828\"\u003eVerify complete de-energization using appropriate electrical test equipment.\u003c\/li\u003e\n\u003cli data-section-id=\"1pql8xr\" data-start=\"3829\" data-end=\"3887\"\u003eFollow the manufacturer’s lockout and tagout procedures.\u003c\/li\u003e\n\u003cli data-section-id=\"1npixmk\" data-start=\"3888\" data-end=\"3957\"\u003eAccess the transfer switch linkage according to the service manual.\u003c\/li\u003e\n\u003cli data-section-id=\"1b06tnu\" data-start=\"3958\" data-end=\"4025\"\u003eNote the position and orientation of the existing arm components.\u003c\/li\u003e\n\u003cli data-section-id=\"df55dj\" data-start=\"4026\" data-end=\"4101\"\u003eRemove the worn or damaged pin and inspect the mating linkage for damage.\u003c\/li\u003e\n\u003cli data-section-id=\"1c0qi97\" data-start=\"4102\" data-end=\"4168\"\u003eAlign the arm extender components before installing the new pin.\u003c\/li\u003e\n\u003cli data-section-id=\"iniern\" data-start=\"4169\" data-end=\"4263\"\u003eInstall any required retaining clip, washer, or related hardware specified for the assembly.\u003c\/li\u003e\n\u003cli data-section-id=\"1ch91dd\" data-start=\"4264\" data-end=\"4338\"\u003eConfirm that the linkage moves freely without binding or excessive play.\u003c\/li\u003e\n\u003cli data-section-id=\"dhyyj9\" data-start=\"4339\" data-end=\"4428\"\u003eReassemble the enclosure and complete the manufacturer’s operational testing procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4430\" data-end=\"4771\"\u003e\u003cstrong data-start=\"4430\" data-end=\"4444\"\u003eImportant:\u003c\/strong\u003e Transfer switches contain hazardous electrical voltages and may be supplied by more than one power source. Installation should be performed by a qualified service technician or licensed electrician. Always verify the transfer switch model, serial number, configuration, parts diagram, and original part number before ordering.\u003c\/p\u003e\n\u003chr data-start=\"4773\" data-end=\"4776\"\u003e\n\u003ch2 data-section-id=\"d80cxu\" data-start=\"4778\" data-end=\"4812\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4781\" data-end=\"4812\"\u003eMaintenance Recommendations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4814\" data-end=\"5540\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1xghlxl\" data-start=\"4814\" data-end=\"4888\"\u003eInspect transfer switch linkage components during scheduled maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"1n068ha\" data-start=\"4889\" data-end=\"4961\"\u003eCheck the arm extender pin for wear, bending, corrosion, or looseness.\u003c\/li\u003e\n\u003cli data-section-id=\"qr1wr0\" data-start=\"4962\" data-end=\"5024\"\u003eConfirm that all linkage components remain properly aligned.\u003c\/li\u003e\n\u003cli data-section-id=\"49rbv7\" data-start=\"5025\" data-end=\"5093\"\u003eInspect retaining clips, washers, and related hardware for damage.\u003c\/li\u003e\n\u003cli data-section-id=\"d72y9b\" data-start=\"5094\" data-end=\"5158\"\u003eKeep the mechanism clean and free of dirt or foreign material.\u003c\/li\u003e\n\u003cli data-section-id=\"1dncz5y\" data-start=\"5159\" data-end=\"5222\"\u003eDo not force linkage components that bind or resist movement.\u003c\/li\u003e\n\u003cli data-section-id=\"21lbtd\" data-start=\"5223\" data-end=\"5284\"\u003eUse only manufacturer-approved lubrication where specified.\u003c\/li\u003e\n\u003cli data-section-id=\"14yom3h\" data-start=\"5285\" data-end=\"5352\"\u003eReplace worn linkage parts before they affect transfer operation.\u003c\/li\u003e\n\u003cli data-section-id=\"1rf73d1\" data-start=\"5353\" data-end=\"5426\"\u003eTest transfer switch operation according to Generac service procedures.\u003c\/li\u003e\n\u003cli data-section-id=\"1bsbbyp\" data-start=\"5427\" data-end=\"5540\" data-is-last-node=\"\"\u003eUse genuine OEM replacement parts to maintain proper fit, alignment, and dependable power-transfer performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Generac","offers":[{"title":"Default Title","offer_id":53593265570155,"sku":"0E6155","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/0E6155.jpg?v=1784745392","url":"https:\/\/generalsprayers.com\/products\/generac-0e6155-arm-extender-pin-genuine-oem-replacement-transfer-switch-arm-pin","provider":"GeneralSprayers","version":"1.0","type":"link"}