{"product_id":"cat-pumps-7590-regulating-unloader-1-inlet-10-52-gpm-800-2300-psi","title":"Cat Pumps 7590 Regulating Unloader – 1″ Inlet, 10–52 GPM, 800–2300 PSI","description":"\u003cp data-start=\"116\" data-end=\"287\"\u003e\u003cstrong data-start=\"116\" data-end=\"126\"\u003eModel:\u003c\/strong\u003e 7590\u003cbr data-start=\"131\" data-end=\"134\"\u003e\u003cstrong data-start=\"134\" data-end=\"147\"\u003eCategory:\u003c\/strong\u003e Pressure Washer → Pump Accessories → Unloaders \/ Regulators\u003cbr data-start=\"207\" data-end=\"210\"\u003e\u003cstrong data-start=\"210\" data-end=\"219\"\u003eType:\u003c\/strong\u003e Regulating Unloader – Pressure Sensitive, Genuine OEM Replacement\u003c\/p\u003e\n\u003chr data-start=\"289\" data-end=\"292\"\u003e\n\u003cp data-start=\"294\" data-end=\"669\"\u003eThe \u003cstrong data-start=\"298\" data-end=\"364\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eCAT Pumps\u003c\/span\u003e\u003c\/span\u003e 7590 Regulating Unloader\u003c\/strong\u003e is a \u003cstrong data-start=\"370\" data-end=\"401\"\u003epressure-sensitive unloader\u003c\/strong\u003e engineered for \u003cstrong data-start=\"417\" data-end=\"452\"\u003esingle or multiple pump systems\u003c\/strong\u003e, including \u003cstrong data-start=\"464\" data-end=\"502\"\u003eweep and multi-nozzle applications\u003c\/strong\u003e. Designed to maintain a \u003cstrong data-start=\"527\" data-end=\"550\"\u003eset system pressure\u003c\/strong\u003e, the 7590 smoothly transitions into bypass when the spray trigger is released or when a downstream obstruction occurs.\u003c\/p\u003e\n\u003cp data-start=\"983\" data-end=\"1103\"\u003e⚠️ \u003cstrong data-start=\"986\" data-end=\"1005\"\u003eOperating Note:\u003c\/strong\u003e For optimal performance, \u003cstrong data-start=\"1031\" data-end=\"1064\"\u003e5–10% bypass flow is required\u003c\/strong\u003e, with a \u003cstrong data-start=\"1073\" data-end=\"1102\"\u003eminimum of 10 GPM per gun\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1105\" data-end=\"1108\"\u003e\n\u003ch3 data-start=\"1110\" data-end=\"1128\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1129\" data-end=\"1322\"\u003e\n\u003cli data-start=\"1129\" data-end=\"1164\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1164\"\u003eSingle or multiple pump systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1165\" data-end=\"1214\"\u003e\n\u003cp data-start=\"1167\" data-end=\"1214\"\u003eWeep and multi-nozzle pressure washer systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1215\" data-end=\"1265\"\u003e\n\u003cp data-start=\"1217\" data-end=\"1265\"\u003eHigh-flow commercial and industrial operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1266\" data-end=\"1322\"\u003e\n\u003cp data-start=\"1268\" data-end=\"1322\"\u003eSystems requiring stable pressure with multiple guns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1324\" data-end=\"1327\"\u003e\n\u003ch3 data-start=\"1329\" data-end=\"1349\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1350\" data-end=\"1582\"\u003e\n\u003cli data-start=\"1350\" data-end=\"1378\"\u003e\n\u003cp data-start=\"1352\" data-end=\"1378\"\u003e\u003cstrong data-start=\"1352\" data-end=\"1369\"\u003eMaximum Flow:\u003c\/strong\u003e 52 GPM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1379\" data-end=\"1415\"\u003e\n\u003cp data-start=\"1381\" data-end=\"1415\"\u003e\u003cstrong data-start=\"1381\" data-end=\"1400\"\u003ePressure Range:\u003c\/strong\u003e 800–2300 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1416\" data-end=\"1449\"\u003e\n\u003cp data-start=\"1418\" data-end=\"1449\"\u003e\u003cstrong data-start=\"1418\" data-end=\"1439\"\u003eMinimum Pressure:\u003c\/strong\u003e 400 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1477\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1477\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1472\"\u003eInlet Port Size:\u003c\/strong\u003e 1″\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1478\" data-end=\"1509\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1509\"\u003e\u003cstrong data-start=\"1480\" data-end=\"1504\"\u003eDischarge Port Size:\u003c\/strong\u003e 1″\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1510\" data-end=\"1553\"\u003e\n\u003cp data-start=\"1512\" data-end=\"1553\"\u003e\u003cstrong data-start=\"1512\" data-end=\"1531\"\u003eAccessory Type:\u003c\/strong\u003e Regulating Unloader\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1554\" data-end=\"1582\"\u003e\n\u003cp data-start=\"1556\" data-end=\"1582\"\u003e\u003cstrong data-start=\"1556\" data-end=\"1569\"\u003eMaterial:\u003c\/strong\u003e Brass (BB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1584\" data-end=\"1587\"\u003e\n\u003ch3 data-start=\"1589\" data-end=\"1610\"\u003eProduct Details\u003c\/h3\u003e\n\u003cp data-start=\"1611\" data-end=\"1790\"\u003e\u003cstrong data-start=\"1611\" data-end=\"1621\"\u003eBrand:\u003c\/strong\u003e CAT Pumps\u003cbr data-start=\"1631\" data-end=\"1634\"\u003e\u003cstrong data-start=\"1634\" data-end=\"1642\"\u003eOEM:\u003c\/strong\u003e Yes – Genuine CAT Pumps Part\u003cbr data-start=\"1671\" data-end=\"1674\"\u003e\u003cstrong data-start=\"1674\" data-end=\"1690\"\u003eApplication:\u003c\/strong\u003e Pressure Regulation \/ Pump Protection\u003cbr data-start=\"1728\" data-end=\"1731\"\u003e\u003cstrong data-start=\"1731\" data-end=\"1749\"\u003eUnloader Type:\u003c\/strong\u003e Pressure-Sensitive Regulating Unloader\u003c\/p\u003e\n\u003chr data-start=\"1792\" data-end=\"1795\"\u003e\n\u003ch3 data-start=\"1797\" data-end=\"1815\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1816\" data-end=\"2244\"\u003e\n\u003cli data-start=\"1816\" data-end=\"1870\"\u003e\n\u003cp data-start=\"1818\" data-end=\"1870\"\u003eGenuine OEM \u003cstrong data-start=\"1830\" data-end=\"1848\"\u003eCAT Pumps 7590\u003c\/strong\u003e regulating unloader\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1871\" data-end=\"1920\"\u003e\n\u003cp data-start=\"1873\" data-end=\"1920\"\u003eDesigned for \u003cstrong data-start=\"1886\" data-end=\"1918\"\u003esingle or multi-pump systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1921\" data-end=\"1958\"\u003e\n\u003cp data-start=\"1923\" data-end=\"1958\"\u003eMaintains consistent set pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1959\" data-end=\"2024\"\u003e\n\u003cp data-start=\"1961\" data-end=\"2024\"\u003eSmooth transition to bypass on trigger release or obstruction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2025\" data-end=\"2083\"\u003e\n\u003cp data-start=\"2027\" data-end=\"2083\"\u003eHolds line pressure during bypass for instant recovery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2084\" data-end=\"2135\"\u003e\n\u003cp data-start=\"2086\" data-end=\"2135\"\u003eMinimal pressure fluctuation with multiple guns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2136\" data-end=\"2188\"\u003e\n\u003cp data-start=\"2138\" data-end=\"2188\"\u003eHeavy-duty \u003cstrong data-start=\"2149\" data-end=\"2171\"\u003ebrass construction\u003c\/strong\u003e for durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2189\" data-end=\"2244\"\u003e\n\u003cp data-start=\"2191\" data-end=\"2244\"\u003eIdeal for \u003cstrong data-start=\"2201\" data-end=\"2229\"\u003ehigh-flow (up to 52 GPM)\u003c\/strong\u003e applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CAT Pumps","offers":[{"title":"Default Title","offer_id":52881253794155,"sku":null,"price":751.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/Cat7590.jpg?v=1770138221","url":"https:\/\/generalsprayers.com\/products\/cat-pumps-7590-regulating-unloader-1-inlet-10-52-gpm-800-2300-psi","provider":"GeneralSprayers","version":"1.0","type":"link"}