{"product_id":"beckett-cleancut-240v-fuel-pump-2184403u-pf20332u-oem-replacement-part","title":"Beckett CleanCut 240V Fuel Pump 2184403U \/ PF20332U – OEM Replacement Part","description":"\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 2184403U\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Burner Components → Fuel Pumps\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Beckett CleanCut 240V Solenoid Fuel Pump\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003eBeckett CleanCut 240V Fuel Pump (2184403U \/ PF20332U)\u003c\/strong\u003e is an advanced oil burner fuel pump engineered to deliver cleaner burner shutdowns, improved combustion performance, and enhanced reliability for modern oil-fired burner systems. Developed in cooperation with \u003cstrong\u003eSuntec Industries\u003c\/strong\u003e, the CleanCut design combines the proven lifting capabilities of traditional American fuel pumps with the clean-burning advantages of an integrated solenoid valve.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cem\u003eImage shown for illustrative purposes only\u003c\/em\u003e\u003cb id=\"docs-internal-guid-34338476-7fff-1b2e-7d54-ec6df5abec72\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Beckett OEM replacement fuel pump\u003c\/li\u003e\n\u003cli\u003eDeveloped in partnership with Suntec Industries\u003c\/li\u003e\n\u003cli\u003eIntegrated CleanCut solenoid valve technology\u003c\/li\u003e\n\u003cli\u003eInstantly stops fuel flow during shutdown\u003c\/li\u003e\n\u003cli\u003eHelps reduce soot formation and carbon buildup\u003c\/li\u003e\n\u003cli\u003eCleaner burner shutdown performance\u003c\/li\u003e\n\u003cli\u003eReduced startup load on burner motors\u003c\/li\u003e\n\u003cli\u003eFewer moving parts than conventional fuel pumps\u003c\/li\u003e\n\u003cli\u003eSimplified fuel system design\u003c\/li\u003e\n\u003cli\u003eReliable protection against fuel leak-through\u003c\/li\u003e\n\u003cli\u003eSuitable for gravity-feed fuel systems\u003c\/li\u003e\n\u003cli\u003eDesigned for modern electronic burner controls\u003c\/li\u003e\n\u003cli\u003eCompatible with #2 and lighter fuel oils\u003c\/li\u003e\n\u003cli\u003eSupports cleaner and more efficient combustion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 2184403U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlternate Part Number:\u003c\/strong\u003e PF20332U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Beckett\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Solenoid Fuel Pump\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e CleanCut\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eHydraulic Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNozzle Pressure Range:\u003c\/strong\u003e 100–200 PSI\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Set Pressure:\u003c\/strong\u003e 100 PSI\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Fluids:\u003c\/strong\u003e #2 and lighter fuel oils\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFuel Viscosity Range:\u003c\/strong\u003e 1.4–12 cSt\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFuel Temperature Range:\u003c\/strong\u003e 32°F–77°F (0°C–25°C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Inlet Pressure:\u003c\/strong\u003e 10 PSI\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Return Pressure:\u003c\/strong\u003e 10 PSI\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Suction Height (One Pipe):\u003c\/strong\u003e 8 ft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Suction Height (Two Pipe):\u003c\/strong\u003e 14 ft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Rated Speed:\u003c\/strong\u003e 3600 RPM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Breakaway Torque:\u003c\/strong\u003e 36 oz-in\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSolenoid Valve Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 200–240 VAC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 9 Watts\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Operating Pressure:\u003c\/strong\u003e 200 PSI\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Ambient Temperature:\u003c\/strong\u003e 155°F (68°C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL, cUL\u003cbr\u003e\u003cem\u003e(50 Hz operation not UL certified)\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHot water pressure washer burners\u003c\/li\u003e\n\u003cli\u003eOil-fired burner systems\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial burner assemblies\u003c\/li\u003e\n\u003cli\u003eFuel oil combustion systems\u003c\/li\u003e\n\u003cli\u003eMobile wash systems\u003c\/li\u003e\n\u003cli\u003eAsphalt maintenance equipment\u003c\/li\u003e\n\u003cli\u003eAgricultural heating equipment\u003c\/li\u003e\n\u003cli\u003eCommercial cleaning equipment\u003c\/li\u003e\n\u003cli\u003eReplacement burner fuel pump installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Signs of Fuel Pump Failure\u003c\/h2\u003e\n\u003cp\u003eA replacement fuel pump may be required if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDelayed burner shutdown\u003c\/li\u003e\n\u003cli\u003eExcessive soot accumulation\u003c\/li\u003e\n\u003cli\u003eHard burner starts\u003c\/li\u003e\n\u003cli\u003eInconsistent fuel pressure\u003c\/li\u003e\n\u003cli\u003eFuel delivery interruptions\u003c\/li\u003e\n\u003cli\u003eBurner ignition failures\u003c\/li\u003e\n\u003cli\u003eFuel leakage issues\u003c\/li\u003e\n\u003cli\u003eReduced combustion efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSolenoid valve immediately stops fuel flow during shutdown\u003c\/li\u003e\n\u003cli\u003eReduces soot formation and burner fouling\u003c\/li\u003e\n\u003cli\u003eCleaner combustion performance\u003c\/li\u003e\n\u003cli\u003eLower startup load on burner motors\u003c\/li\u003e\n\u003cli\u003eFewer fuel fittings and moving parts\u003c\/li\u003e\n\u003cli\u003eImproved reliability over traditional designs\u003c\/li\u003e\n\u003cli\u003eExcellent fuel lift capabilities\u003c\/li\u003e\n\u003cli\u003eSupports efficient burner operation and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing burner equipment.\u003c\/li\u003e\n\u003cli\u003eVerify fuel supply lines are clean and contamination-free.\u003c\/li\u003e\n\u003cli\u003eInstall the CleanCut pump according to burner manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003eConfirm proper fuel line routing and connections.\u003c\/li\u003e\n\u003cli\u003eSet operating pressure as required for the burner application.\u003c\/li\u003e\n\u003cli\u003eInspect all fittings for leaks before startup.\u003c\/li\u003e\n\u003cli\u003eVerify proper operation of burner controls and solenoid valve.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The Beckett CleanCut pump must be used with a \u003cstrong\u003emodern electronic burner control featuring a pre-purge or valve-on delay\u003c\/strong\u003e, such as a Beckett PD Timer. Controls without a delay may result in hard starting and improper burner operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain a clean, water-free fuel supply.\u003c\/li\u003e\n\u003cli\u003eReplace fuel filters at recommended intervals.\u003c\/li\u003e\n\u003cli\u003eInspect fuel lines for contamination or restrictions.\u003c\/li\u003e\n\u003cli\u003eVerify fuel pressure during routine service.\u003c\/li\u003e\n\u003cli\u003eCheck solenoid operation periodically.\u003c\/li\u003e\n\u003cli\u003eAvoid unnecessary pressure adjustments.\u003c\/li\u003e\n\u003cli\u003eInspect fittings and seals for leakage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beckett","offers":[{"title":"Default Title","offer_id":53407918489963,"sku":null,"price":155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/2184403UFuelPump.jpg?v=1781792687","url":"https:\/\/generalsprayers.com\/products\/beckett-cleancut-240v-fuel-pump-2184403u-pf20332u-oem-replacement-part","provider":"GeneralSprayers","version":"1.0","type":"link"}