{"product_id":"5270001u-beckett-a-powerlight-12vdc-ignitor-with-cad-cell-oem-replacement-part","title":"5270001U Beckett A PowerLight 12VDC Ignitor with Cad Cell – OEM Replacement Part","description":"\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5270001U\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Burner Components → Ignitors \u0026amp; Flame Detection Systems\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Beckett A PowerLight 12VDC Ignitor with Cad Cell\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003eBeckett 5270001U A PowerLight 12VDC Ignitor with Cad Cell\u003c\/strong\u003e is an advanced electronic ignition system designed for 12-volt oil burner applications used in hot water pressure washers, mobile wash systems, road stripers, asphalt equipment, and other commercial burner applications. Combining a high-performance electronic ignitor with an included cad cell flame sensor, this unit delivers reliable ignition, improved durability, and simplified installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Beckett PowerLight ignitor assembly\u003c\/li\u003e\n\u003cli\u003eIncludes cad cell flame sensor (not pre-installed)\u003c\/li\u003e\n\u003cli\u003eDesigned for 12VDC burner systems\u003c\/li\u003e\n\u003cli\u003ePowerful 20kV peak ignition output\u003c\/li\u003e\n\u003cli\u003eUniversal replacement design\u003c\/li\u003e\n\u003cli\u003eCompatible with Beckett and many other burner brands\u003c\/li\u003e\n\u003cli\u003eEliminates external heat sink design\u003c\/li\u003e\n\u003cli\u003eImproved resistance to overheating and arcing\u003c\/li\u003e\n\u003cli\u003eFully potted waterproof electronic construction\u003c\/li\u003e\n\u003cli\u003eEnhanced thermal shock protection\u003c\/li\u003e\n\u003cli\u003eSimplified wiring with fewer connections\u003c\/li\u003e\n\u003cli\u003eLightweight single-piece design\u003c\/li\u003e\n\u003cli\u003eSupports interrupted ignition conversion\u003c\/li\u003e\n\u003cli\u003eHelps increase ignitor service life\u003c\/li\u003e\n\u003cli\u003eReduces maintenance and replacement frequency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5270001U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Beckett\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e PowerLight\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electronic Ignitor with Cad Cell\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCad Cell Included:\u003c\/strong\u003e Yes (Not Installed)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 10.8–16 VDC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e 1.8 Amps\u003c\/p\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 20kV Peak\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 25mA RMS\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003ch3\u003eOperating Temperature\u003c\/h3\u003e\n\u003cp\u003e-40°F to 150°F\u003c\/p\u003e\n\u003ch3\u003eStorage Temperature\u003c\/h3\u003e\n\u003cp\u003e-40°F to 150°F\u003c\/p\u003e\n\u003ch3\u003eHumidity\u003c\/h3\u003e\n\u003cp\u003e5% to 95% Relative Humidity\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Applications\u003c\/h2\u003e\n\u003cp\u003eCommonly used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHot water pressure washer burners\u003c\/li\u003e\n\u003cli\u003eMobile wash rigs\u003c\/li\u003e\n\u003cli\u003eRoad striping equipment\u003c\/li\u003e\n\u003cli\u003eCrack sealing equipment\u003c\/li\u003e\n\u003cli\u003eAsphalt distributors\u003c\/li\u003e\n\u003cli\u003eHot patch equipment\u003c\/li\u003e\n\u003cli\u003eOil burner systems\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial burner applications\u003c\/li\u003e\n\u003cli\u003eMobile maintenance equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Signs of Ignitor Failure\u003c\/h2\u003e\n\u003cp\u003eA replacement ignitor may be needed if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurner fails to ignite\u003c\/li\u003e\n\u003cli\u003eDelayed burner startup\u003c\/li\u003e\n\u003cli\u003eWeak ignition spark\u003c\/li\u003e\n\u003cli\u003eFrequent burner lockouts\u003c\/li\u003e\n\u003cli\u003eIgnition-related fault codes\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eExcessive arcing\u003c\/li\u003e\n\u003cli\u003eDamaged or deteriorated ignitor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-voltage ignition improves burner startup reliability\u003c\/li\u003e\n\u003cli\u003eEliminates external heat sink failure points\u003c\/li\u003e\n\u003cli\u003eFully sealed design protects electronics from moisture\u003c\/li\u003e\n\u003cli\u003eImproved resistance to vibration and thermal shock\u003c\/li\u003e\n\u003cli\u003eSupports longer ignitor service life\u003c\/li\u003e\n\u003cli\u003eReduced wiring simplifies installation\u003c\/li\u003e\n\u003cli\u003eUniversal fitment reduces replacement inventory needs\u003c\/li\u003e\n\u003cli\u003eIncluded cad cell provides flame monitoring capability\u003c\/li\u003e\n\u003cli\u003eIdeal for demanding commercial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Instructions\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power from the burner system.\u003c\/li\u003e\n\u003cli\u003eAllow burner components to cool completely.\u003c\/li\u003e\n\u003cli\u003eRemove the existing ignitor assembly.\u003c\/li\u003e\n\u003cli\u003eInspect ignition wiring and burner components.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement PowerLight ignitor.\u003c\/li\u003e\n\u003cli\u003eInstall the included cad cell if required by the burner system.\u003c\/li\u003e\n\u003cli\u003eConnect wiring according to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003eVerify proper voltage compatibility.\u003c\/li\u003e\n\u003cli\u003eRestore power and test burner startup and flame detection functions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The included cad cell is supplied separately and must be installed according to burner manufacturer requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInspect ignition components during routine burner service.\u003c\/li\u003e\n\u003cli\u003eVerify cad cell cleanliness and proper positioning.\u003c\/li\u003e\n\u003cli\u003eCheck wiring connections regularly.\u003c\/li\u003e\n\u003cli\u003eInspect electrodes for proper gap and condition.\u003c\/li\u003e\n\u003cli\u003eKeep burner compartments clean and dry.\u003c\/li\u003e\n\u003cli\u003eReplace damaged ignition or flame-sensing components promptly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beckett","offers":[{"title":"Default Title","offer_id":53405303865707,"sku":"5270001U","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/5270001U.webp?v=1781741219","url":"https:\/\/generalsprayers.com\/products\/5270001u-beckett-a-powerlight-12vdc-ignitor-with-cad-cell-oem-replacement-part","provider":"GeneralSprayers","version":"1.0","type":"link"}