{"product_id":"51838u-120v-electric-ignitor-oem-replacement-part","title":"51838U 120V Electric Ignitor – OEM Replacement Part","description":"\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51838U\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Burner Components → Ignitors \u0026amp; Ignition Transformers\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e 51838U 120V Electric Ignitor\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003e51838U 120V Electric Ignitor (Part #5054)\u003c\/strong\u003e is a versatile, high-performance electronic ignition transformer designed for oil burner systems used in hot water pressure washers, heating equipment, and industrial combustion applications. Engineered to provide reliable ignition performance, this ignitor generates a powerful high-voltage spark that ensures fast and efficient burner startup.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cem\u003eImage shown for illustrative purposes only\u003c\/em\u003e\u003cb id=\"docs-internal-guid-e485561d-7fff-530e-ffe2-c17501402067\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOEM replacement 120V electric ignitor\u003c\/li\u003e\n\u003cli\u003ePowerful 20kV peak ignition output\u003c\/li\u003e\n\u003cli\u003eDelivers fast and efficient burner ignition\u003c\/li\u003e\n\u003cli\u003eCompatible with multiple burner platforms\u003c\/li\u003e\n\u003cli\u003eUniversal base plate adaptability\u003c\/li\u003e\n\u003cli\u003eFits many competitor transformer base plates\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight design\u003c\/li\u003e\n\u003cli\u003eVacuum-encapsulated synthetic resin construction\u003c\/li\u003e\n\u003cli\u003eExcellent moisture resistance\u003c\/li\u003e\n\u003cli\u003eSuperior electrical insulation properties\u003c\/li\u003e\n\u003cli\u003eHigh-temperature thermoplastic housing\u003c\/li\u003e\n\u003cli\u003eImpact-resistant and scratch-resistant construction\u003c\/li\u003e\n\u003cli\u003eChemical-resistant housing design\u003c\/li\u003e\n\u003cli\u003eUL recognized in the United States and Canada\u003c\/li\u003e\n\u003cli\u003eIntegrated wire routing and protection features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5054\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 51838U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electronic Burner Ignitor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 1.1 lbs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 VAC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 35 VA\u003c\/p\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 6kV RMS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak Voltage:\u003c\/strong\u003e 20kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 35mA RMS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary:\u003c\/strong\u003e Mid-Point Ground\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003ch3\u003eOperating Temperature\u003c\/h3\u003e\n\u003cp\u003e-20°F to 150°F\u003c\/p\u003e\n\u003ch3\u003eStorage Temperature\u003c\/h3\u003e\n\u003cp\u003e-40°F to 150°F\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Burner Systems\u003c\/h2\u003e\n\u003cp\u003eDesigned to adapt to:\u003c\/p\u003e\n\u003ch3\u003eBeckett\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA\u003c\/li\u003e\n\u003cli\u003eAF\u003c\/li\u003e\n\u003cli\u003eAFG\u003c\/li\u003e\n\u003cli\u003eS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAero\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVarious compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCarlin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e100\u003c\/li\u003e\n\u003cli\u003e101CRD\u003c\/li\u003e\n\u003cli\u003e102CRD\u003c\/li\u003e\n\u003cli\u003e200\u003c\/li\u003e\n\u003cli\u003e201\u003c\/li\u003e\n\u003cli\u003e500CRD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWayne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eM\u003c\/li\u003e\n\u003cli\u003eE\u003c\/li\u003e\n\u003cli\u003eHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWeil-McLain\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVarious compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe versatile design also fits many other manufacturer transformer base plates.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Applications\u003c\/h2\u003e\n\u003cp\u003eCommonly used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHot water pressure washer burners\u003c\/li\u003e\n\u003cli\u003eFuel oil burner systems\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial burner assemblies\u003c\/li\u003e\n\u003cli\u003eMobile wash rigs\u003c\/li\u003e\n\u003cli\u003eFleet washing equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial cleaning systems\u003c\/li\u003e\n\u003cli\u003eCommercial maintenance equipment\u003c\/li\u003e\n\u003cli\u003eBurner service and repair applications\u003c\/li\u003e\n\u003cli\u003eFuel-fired heating equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Signs of Ignitor Failure\u003c\/h2\u003e\n\u003cp\u003eA replacement ignitor may be needed if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurner fails to ignite\u003c\/li\u003e\n\u003cli\u003eWeak ignition spark\u003c\/li\u003e\n\u003cli\u003eDelayed startup\u003c\/li\u003e\n\u003cli\u003eFrequent ignition lockouts\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eDamaged ignitor housing\u003c\/li\u003e\n\u003cli\u003eExcessive ignition noise\u003c\/li\u003e\n\u003cli\u003eNo spark output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-output ignition promotes reliable burner startup\u003c\/li\u003e\n\u003cli\u003eUniversal compatibility reduces inventory requirements\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant design improves reliability\u003c\/li\u003e\n\u003cli\u003eExcellent thermal management characteristics\u003c\/li\u003e\n\u003cli\u003eDurable housing withstands harsh environments\u003c\/li\u003e\n\u003cli\u003eHelps reduce burner downtime\u003c\/li\u003e\n\u003cli\u003eSupports efficient combustion system performance\u003c\/li\u003e\n\u003cli\u003eSuitable for demanding commercial applications\u003c\/li\u003e\n\u003cli\u003eLong service life under heavy-duty operating conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Instructions\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power to the burner system.\u003c\/li\u003e\n\u003cli\u003eAllow all burner components to cool completely.\u003c\/li\u003e\n\u003cli\u003eRemove the existing ignitor assembly.\u003c\/li\u003e\n\u003cli\u003eInspect wiring and ignition components.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement 51838U ignitor onto the appropriate base plate.\u003c\/li\u003e\n\u003cli\u003eRoute wires through the integrated breakout sections as needed.\u003c\/li\u003e\n\u003cli\u003eSecure all electrical connections.\u003c\/li\u003e\n\u003cli\u003eRestore power and test burner operation.\u003c\/li\u003e\n\u003cli\u003eVerify proper ignition and burner startup performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Always follow burner manufacturer installation procedures and wiring specifications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInspect ignition components during routine burner maintenance.\u003c\/li\u003e\n\u003cli\u003eVerify secure wiring connections.\u003c\/li\u003e\n\u003cli\u003eCheck ignition electrodes for proper condition and gap settings.\u003c\/li\u003e\n\u003cli\u003eKeep burner compartments clean and dry.\u003c\/li\u003e\n\u003cli\u003eInspect the ignitor housing for signs of damage.\u003c\/li\u003e\n\u003cli\u003eReplace ignition components showing signs of wear or failure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beckett","offers":[{"title":"Default Title","offer_id":53405280469355,"sku":null,"price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/51838UIgnitor_40ef2835-5035-47be-96e8-8791709d5532.jpg?v=1781740317","url":"https:\/\/generalsprayers.com\/products\/51838u-120v-electric-ignitor-oem-replacement-part","provider":"GeneralSprayers","version":"1.0","type":"link"}