{"product_id":"22760a-ul180-black-spring-unloader-valve-3000-psi-8-gpm-oem-replacement-part","title":"22760A UL180 Black Spring Unloader Valve 3000 PSI 8 GPM – OEM Replacement Part","description":"\u003cp data-start=\"0\" data-end=\"164\"\u003e\u003cstrong data-start=\"0\" data-end=\"16\"\u003ePart Number:\u003c\/strong\u003e 2168\u003cbr data-start=\"21\" data-end=\"24\"\u003e\u003cstrong data-start=\"24\" data-end=\"37\"\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Unloader Valves → Pressure Washer Regulators\u003cbr data-start=\"106\" data-end=\"109\"\u003e\u003cstrong data-start=\"109\" data-end=\"118\"\u003eType:\u003c\/strong\u003e Giant Pumps UL180 Black Spring Unloader Valve\u003c\/p\u003e\n\u003chr data-start=\"166\" data-end=\"169\"\u003e\n\u003cp data-start=\"259\" data-end=\"693\"\u003eThe \u003cstrong data-start=\"263\" data-end=\"332\"\u003eGiant Pumps 22760A UL180 Black Spring Unloader Valve (Part #2168)\u003c\/strong\u003e is a reliable OEM replacement unloader designed to regulate system pressure and protect pressure washer components from damaging pressure buildup. Engineered by \u003cstrong data-start=\"494\" data-end=\"509\"\u003eGiant Pumps\u003c\/strong\u003e, this commercial-duty unloader is rated for up to \u003cstrong data-start=\"560\" data-end=\"573\"\u003e3,000 PSI\u003c\/strong\u003e, \u003cstrong data-start=\"575\" data-end=\"584\"\u003e8 GPM\u003c\/strong\u003e, and operating temperatures up to \u003cstrong data-start=\"619\" data-end=\"628\"\u003e160°F\u003c\/strong\u003e, making it ideal for professional pressure washing applications.\u003c\/p\u003e\n\u003chr data-start=\"1293\" data-end=\"1296\"\u003e\n\u003ch2 data-section-id=\"939trr\" data-start=\"1298\" data-end=\"1324\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1326\" data-end=\"1808\"\u003e\n\u003cli data-section-id=\"zf8d86\" data-start=\"1326\" data-end=\"1378\"\u003eGenuine Giant Pumps OEM replacement unloader valve\u003c\/li\u003e\n\u003cli data-section-id=\"gbeyb2\" data-start=\"1379\" data-end=\"1413\"\u003eUL180 black spring configuration\u003c\/li\u003e\n\u003cli data-section-id=\"w06eb9\" data-start=\"1414\" data-end=\"1437\"\u003eRated up to 3,000 PSI\u003c\/li\u003e\n\u003cli data-section-id=\"1d0ei23\" data-start=\"1438\" data-end=\"1471\"\u003eSupports flow rates up to 8 GPM\u003c\/li\u003e\n\u003cli data-section-id=\"1tjntnq\" data-start=\"1472\" data-end=\"1518\"\u003eAutomatically diverts water into bypass mode\u003c\/li\u003e\n\u003cli data-section-id=\"26wjm6\" data-start=\"1519\" data-end=\"1561\"\u003eHelps protect pumps from pressure spikes\u003c\/li\u003e\n\u003cli data-section-id=\"1pt5a32\" data-start=\"1562\" data-end=\"1594\"\u003eAdjustable pressure regulation\u003c\/li\u003e\n\u003cli data-section-id=\"1fslglz\" data-start=\"1595\" data-end=\"1650\"\u003eDual inlet and bypass ports for flexible installation\u003c\/li\u003e\n\u003cli data-section-id=\"1wspswh\" data-start=\"1651\" data-end=\"1682\"\u003eCommercial-grade construction\u003c\/li\u003e\n\u003cli data-section-id=\"ng3c0i\" data-start=\"1683\" data-end=\"1710\"\u003eReliable pressure control\u003c\/li\u003e\n\u003cli data-section-id=\"3u46tj\" data-start=\"1711\" data-end=\"1761\"\u003eSuitable for hot and cold water pressure washers\u003c\/li\u003e\n\u003cli data-section-id=\"kidvb2\" data-start=\"1762\" data-end=\"1808\"\u003eLong service life and dependable performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1810\" data-end=\"1813\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1815\" data-end=\"1842\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1844\" data-end=\"1865\"\u003e\u003cstrong data-start=\"1844\" data-end=\"1860\"\u003ePart Number:\u003c\/strong\u003e 2168\u003c\/p\u003e\n\u003cp data-start=\"1867\" data-end=\"1896\"\u003e\u003cstrong data-start=\"1867\" data-end=\"1884\"\u003eManufacturer:\u003c\/strong\u003e Giant Pumps\u003c\/p\u003e\n\u003cp data-start=\"1898\" data-end=\"1934\"\u003e\u003cstrong data-start=\"1898\" data-end=\"1927\"\u003eManufacturer Part Number:\u003c\/strong\u003e 22760A\u003c\/p\u003e\n\u003cp data-start=\"1936\" data-end=\"1952\"\u003e\u003cstrong data-start=\"1936\" data-end=\"1946\"\u003eModel:\u003c\/strong\u003e UL180\u003c\/p\u003e\n\u003cp data-start=\"1954\" data-end=\"1977\"\u003e\u003cstrong data-start=\"1954\" data-end=\"1971\"\u003eSpring Color:\u003c\/strong\u003e Black\u003c\/p\u003e\n\u003cp data-start=\"1979\" data-end=\"2027\"\u003e\u003cstrong data-start=\"1979\" data-end=\"1996\"\u003eProduct Type:\u003c\/strong\u003e Pressure Washer Unloader Valve\u003c\/p\u003e\n\u003cp data-start=\"2029\" data-end=\"2060\"\u003e\u003cstrong data-start=\"2029\" data-end=\"2050\"\u003eMaximum Pressure:\u003c\/strong\u003e 3,000 PSI\u003c\/p\u003e\n\u003cp data-start=\"2062\" data-end=\"2090\"\u003e\u003cstrong data-start=\"2062\" data-end=\"2084\"\u003eMaximum Flow Rate:\u003c\/strong\u003e 8 GPM\u003c\/p\u003e\n\u003cp data-start=\"2092\" data-end=\"2122\"\u003e\u003cstrong data-start=\"2092\" data-end=\"2116\"\u003eMaximum Temperature:\u003c\/strong\u003e 160°F\u003c\/p\u003e\n\u003cp data-start=\"2124\" data-end=\"2160\"\u003e\u003cstrong data-start=\"2124\" data-end=\"2146\"\u003eInlet Connections:\u003c\/strong\u003e Dual 3\/8\" FPT\u003c\/p\u003e\n\u003cp data-start=\"2162\" data-end=\"2193\"\u003e\u003cstrong data-start=\"2162\" data-end=\"2184\"\u003eOutlet Connection:\u003c\/strong\u003e 3\/8\" FPT\u003c\/p\u003e\n\u003cp data-start=\"2195\" data-end=\"2232\"\u003e\u003cstrong data-start=\"2195\" data-end=\"2218\"\u003eBypass Connections:\u003c\/strong\u003e Dual 1\/4\" FPT\u003c\/p\u003e\n\u003cp data-start=\"2234\" data-end=\"2258\"\u003e\u003cstrong data-start=\"2234\" data-end=\"2254\"\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr data-start=\"2260\" data-end=\"2263\"\u003e\n\u003ch2 data-section-id=\"1kehdxb\" data-start=\"2265\" data-end=\"2295\"\u003eWhat an Unloader Valve Does\u003c\/h2\u003e\n\u003cp data-start=\"2297\" data-end=\"2337\"\u003eThe UL180 unloader valve is designed to:\u003c\/p\u003e\n\u003cul data-start=\"2339\" data-end=\"2554\"\u003e\n\u003cli data-section-id=\"1guzp1l\" data-start=\"2339\" data-end=\"2368\"\u003eRegulate operating pressure\u003c\/li\u003e\n\u003cli data-section-id=\"9gt2jc\" data-start=\"2369\" data-end=\"2419\"\u003eDivert water flow when the spray gun is released\u003c\/li\u003e\n\u003cli data-section-id=\"syvdyp\" data-start=\"2420\" data-end=\"2456\"\u003ePrevent excessive pressure buildup\u003c\/li\u003e\n\u003cli data-section-id=\"1est7ul\" data-start=\"2457\" data-end=\"2493\"\u003eProtect pumps, hoses, and fittings\u003c\/li\u003e\n\u003cli data-section-id=\"1eg0b0n\" data-start=\"2494\" data-end=\"2522\"\u003eImprove system reliability\u003c\/li\u003e\n\u003cli data-section-id=\"13l284f\" data-start=\"2523\" data-end=\"2554\"\u003eExtend equipment service life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2556\" data-end=\"2658\"\u003eWhen the trigger gun is closed, water is redirected through the bypass circuit until cleaning resumes.\u003c\/p\u003e\n\u003chr data-start=\"2660\" data-end=\"2663\"\u003e\n\u003ch2 data-section-id=\"xz0xt5\" data-start=\"2665\" data-end=\"2701\"\u003eDual-Port Installation Advantages\u003c\/h2\u003e\n\u003cp data-start=\"2703\" data-end=\"2763\"\u003eThe UL180 features dual inlet and bypass ports that provide:\u003c\/p\u003e\n\u003cul data-start=\"2765\" data-end=\"2975\"\u003e\n\u003cli data-section-id=\"1n662zl\" data-start=\"2765\" data-end=\"2795\"\u003eGreater plumbing flexibility\u003c\/li\u003e\n\u003cli data-section-id=\"gfratp\" data-start=\"2796\" data-end=\"2825\"\u003eEasier installation options\u003c\/li\u003e\n\u003cli data-section-id=\"xp84jx\" data-start=\"2826\" data-end=\"2869\"\u003eCompatibility with various system layouts\u003c\/li\u003e\n\u003cli data-section-id=\"1pzcg60\" data-start=\"2870\" data-end=\"2913\"\u003eSimplified pressure washer configurations\u003c\/li\u003e\n\u003cli data-section-id=\"1p82e2b\" data-start=\"2914\" data-end=\"2975\"\u003eImproved versatility for equipment builders and technicians\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2977\" data-end=\"2980\"\u003e\n\u003ch2 data-section-id=\"vx2wyp\" data-start=\"2982\" data-end=\"3004\"\u003eCommon Applications\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1m4yfbj\" data-start=\"3006\" data-end=\"3033\"\u003ePressure Washer Systems\u003c\/h3\u003e\n\u003cp data-start=\"3035\" data-end=\"3045\"\u003eIdeal for:\u003c\/p\u003e\n\u003cul data-start=\"3047\" data-end=\"3184\"\u003e\n\u003cli data-section-id=\"1ftw8hk\" data-start=\"3047\" data-end=\"3076\"\u003eCommercial pressure washers\u003c\/li\u003e\n\u003cli data-section-id=\"sjf9mw\" data-start=\"3077\" data-end=\"3108\"\u003eContractor cleaning equipment\u003c\/li\u003e\n\u003cli data-section-id=\"i17fze\" data-start=\"3109\" data-end=\"3127\"\u003eMobile wash rigs\u003c\/li\u003e\n\u003cli data-section-id=\"1hb3h7x\" data-start=\"3128\" data-end=\"3151\"\u003eFleet washing systems\u003c\/li\u003e\n\u003cli data-section-id=\"1hkm1a0\" data-start=\"3152\" data-end=\"3184\"\u003eProperty maintenance equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"tgue5k\" data-start=\"3186\" data-end=\"3213\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul data-start=\"3215\" data-end=\"3354\"\u003e\n\u003cli data-section-id=\"9ezizr\" data-start=\"3215\" data-end=\"3235\"\u003eEquipment cleaning\u003c\/li\u003e\n\u003cli data-section-id=\"1i0u86j\" data-start=\"3236\" data-end=\"3262\"\u003eManufacturing facilities\u003c\/li\u003e\n\u003cli data-section-id=\"7a3rsy\" data-start=\"3263\" data-end=\"3294\"\u003eAgricultural cleaning systems\u003c\/li\u003e\n\u003cli data-section-id=\"5l5kua\" data-start=\"3295\" data-end=\"3320\"\u003eMaintenance departments\u003c\/li\u003e\n\u003cli data-section-id=\"ee50fv\" data-start=\"3321\" data-end=\"3354\"\u003eIndustrial wash-down operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3356\" data-end=\"3359\"\u003e\n\u003ch2 data-section-id=\"ctfpuh\" data-start=\"3361\" data-end=\"3384\"\u003ePerformance Benefits\u003c\/h2\u003e\n\u003cul data-start=\"3386\" data-end=\"3615\"\u003e\n\u003cli data-section-id=\"1bl7wox\" data-start=\"3386\" data-end=\"3416\"\u003eReliable pressure regulation\u003c\/li\u003e\n\u003cli data-section-id=\"1gpagnp\" data-start=\"3417\" data-end=\"3450\"\u003eConsistent cleaning performance\u003c\/li\u003e\n\u003cli data-section-id=\"10h3yid\" data-start=\"3451\" data-end=\"3470\"\u003eReduced pump wear\u003c\/li\u003e\n\u003cli data-section-id=\"10ti500\" data-start=\"3471\" data-end=\"3499\"\u003eImproved system protection\u003c\/li\u003e\n\u003cli data-section-id=\"1v4av2j\" data-start=\"3500\" data-end=\"3527\"\u003eFlexible plumbing options\u003c\/li\u003e\n\u003cli data-section-id=\"1nzrik5\" data-start=\"3528\" data-end=\"3553\"\u003eSmooth bypass operation\u003c\/li\u003e\n\u003cli data-section-id=\"1kjg8fj\" data-start=\"3554\" data-end=\"3583\"\u003eExtended equipment lifespan\u003c\/li\u003e\n\u003cli data-section-id=\"c81ntm\" data-start=\"3584\" data-end=\"3615\"\u003eProfessional-grade durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3617\" data-end=\"3620\"\u003e\n\u003ch2 data-section-id=\"x2tt67\" data-start=\"3622\" data-end=\"3666\"\u003eSigns an Unloader Valve Needs Replacement\u003c\/h2\u003e\n\u003cp data-start=\"3668\" data-end=\"3707\"\u003eReplace the unloader if you experience:\u003c\/p\u003e\n\u003cul data-start=\"3709\" data-end=\"3948\"\u003e\n\u003cli data-section-id=\"zta6im\" data-start=\"3709\" data-end=\"3732\"\u003ePressure fluctuations\u003c\/li\u003e\n\u003cli data-section-id=\"1bsd0c4\" data-start=\"3733\" data-end=\"3761\"\u003ePressure spikes or surging\u003c\/li\u003e\n\u003cli data-section-id=\"ldy9cv\" data-start=\"3762\" data-end=\"3792\"\u003eWater leaks around the valve\u003c\/li\u003e\n\u003cli data-section-id=\"1lcacgl\" data-start=\"3793\" data-end=\"3823\"\u003eInconsistent pressure output\u003c\/li\u003e\n\u003cli data-section-id=\"op63ib\" data-start=\"3824\" data-end=\"3855\"\u003eDifficulty adjusting pressure\u003c\/li\u003e\n\u003cli data-section-id=\"uz2anl\" data-start=\"3856\" data-end=\"3879\"\u003eExcessive bypass flow\u003c\/li\u003e\n\u003cli data-section-id=\"1n1a9ox\" data-start=\"3880\" data-end=\"3910\"\u003eReduced cleaning performance\u003c\/li\u003e\n\u003cli data-section-id=\"15bz8bp\" data-start=\"3911\" data-end=\"3948\"\u003eWorn or damaged internal components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3950\" data-end=\"3953\"\u003e\n\u003ch2 data-section-id=\"16dprsq\" data-start=\"3955\" data-end=\"3976\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003col data-start=\"3978\" data-end=\"4388\"\u003e\n\u003cli data-section-id=\"1n541am\" data-start=\"3978\" data-end=\"4042\"\u003eTurn off the pressure washer and relieve all system pressure.\u003c\/li\u003e\n\u003cli data-section-id=\"xktq8x\" data-start=\"4043\" data-end=\"4105\"\u003eVerify compatibility with system flow and pressure ratings.\u003c\/li\u003e\n\u003cli data-section-id=\"cqc1w2\" data-start=\"4106\" data-end=\"4168\"\u003eSelect the appropriate inlet and bypass port configuration.\u003c\/li\u003e\n\u003cli data-section-id=\"1lhhw4v\" data-start=\"4169\" data-end=\"4208\"\u003eApply thread sealant where required.\u003c\/li\u003e\n\u003cli data-section-id=\"xl2js7\" data-start=\"4209\" data-end=\"4268\"\u003eInstall the valve according to equipment specifications.\u003c\/li\u003e\n\u003cli data-section-id=\"1qp34u6\" data-start=\"4269\" data-end=\"4331\"\u003eAdjust pressure settings using a calibrated pressure gauge.\u003c\/li\u003e\n\u003cli data-section-id=\"5tkux2\" data-start=\"4332\" data-end=\"4388\"\u003eVerify proper bypass operation and inspect for leaks.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"4390\" data-end=\"4531\"\u003e\u003cstrong data-start=\"4390\" data-end=\"4404\"\u003eImportant:\u003c\/strong\u003e Always ensure the pressure washer pump, hoses, spray gun, and fittings are rated for the system's operating pressure and flow.\u003c\/p\u003e\n\u003chr data-start=\"4533\" data-end=\"4536\"\u003e\n\u003ch2 data-section-id=\"8fimbm\" data-start=\"4538\" data-end=\"4568\"\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul data-start=\"4570\" data-end=\"4843\"\u003e\n\u003cli data-section-id=\"8e7fsu\" data-start=\"4570\" data-end=\"4609\"\u003eInspect regularly for leaks and wear.\u003c\/li\u003e\n\u003cli data-section-id=\"1bk99f5\" data-start=\"4610\" data-end=\"4664\"\u003eVerify pressure settings during routine maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"1q0brl4\" data-start=\"4665\" data-end=\"4703\"\u003eCheck bypass operation periodically.\u003c\/li\u003e\n\u003cli data-section-id=\"1vsppvb\" data-start=\"4704\" data-end=\"4738\"\u003eMaintain clean water filtration.\u003c\/li\u003e\n\u003cli data-section-id=\"1evoa83\" data-start=\"4739\" data-end=\"4797\"\u003eReplace worn seals and internal components as necessary.\u003c\/li\u003e\n\u003cli data-section-id=\"fuze7i\" data-start=\"4798\" data-end=\"4843\"\u003eFollow Giant Pumps service recommendations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Giant","offers":[{"title":"Default Title","offer_id":53428883456363,"sku":null,"price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/22760AUNLOADER.webp?v=1782497179","url":"https:\/\/generalsprayers.com\/products\/22760a-ul180-black-spring-unloader-valve-3000-psi-8-gpm-oem-replacement-part","provider":"GeneralSprayers","version":"1.0","type":"link"}