{"product_id":"115v-air-solenoid-valve-1-2-npt-normally-closed-pneumatic-control-valve-replaces-clemco-12191","title":"115V Air Solenoid Valve – 1\/2\" NPT Normally Closed – Pneumatic Control Valve – Replaces Clemco 12191","description":"\u003cp data-start=\"159\" data-end=\"301\"\u003e\u003cstrong data-start=\"159\" data-end=\"169\"\u003eModel:\u003c\/strong\u003e 1569-4400\u003cbr data-start=\"179\" data-end=\"182\"\u003e\u003cstrong data-start=\"182\" data-end=\"195\"\u003eCategory:\u003c\/strong\u003e Abrasive Blasting Equipment → Valves \u0026amp; Control Systems\u003cbr data-start=\"250\" data-end=\"253\"\u003e\u003cstrong data-start=\"253\" data-end=\"262\"\u003eType:\u003c\/strong\u003e Air Solenoid Valve (Normally Closed)\u003c\/p\u003e\n\u003cp data-start=\"303\" data-end=\"610\"\u003eThe \u003cstrong data-start=\"307\" data-end=\"346\"\u003e115V Air Solenoid Valve (1569-4400)\u003c\/strong\u003e is an electrically actuated control valve designed to \u003cstrong data-start=\"401\" data-end=\"434\"\u003eautomatically control airflow\u003c\/strong\u003e in abrasive blasting and pneumatic systems. With a \u003cstrong data-start=\"486\" data-end=\"510\"\u003enormally closed (NC)\u003c\/strong\u003e configuration, the valve remains shut until energized, providing \u003cstrong data-start=\"576\" data-end=\"609\"\u003esafe and controlled operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"778\" data-end=\"781\"\u003e\n\u003ch3 data-section-id=\"dka8qc\" data-start=\"783\" data-end=\"810\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"811\" data-end=\"1109\"\u003e\n\u003cli data-section-id=\"1ku7yn8\" data-start=\"811\" data-end=\"851\"\u003e\u003cstrong data-start=\"813\" data-end=\"849\"\u003e115V electric solenoid operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"e0ubju\" data-start=\"852\" data-end=\"910\"\u003e\n\u003cstrong data-start=\"854\" data-end=\"878\"\u003eNormally Closed (NC)\u003c\/strong\u003e for fail-safe airflow control\u003c\/li\u003e\n\u003cli data-section-id=\"txzwj\" data-start=\"911\" data-end=\"958\"\u003e\n\u003cstrong data-start=\"913\" data-end=\"931\"\u003e1\/2\" NPT ports\u003c\/strong\u003e for standard connections\u003c\/li\u003e\n\u003cli data-section-id=\"1ppxoo\" data-start=\"959\" data-end=\"1016\"\u003eEnables \u003cstrong data-start=\"969\" data-end=\"994\"\u003eautomated air control\u003c\/strong\u003e in blasting systems\u003c\/li\u003e\n\u003cli data-section-id=\"1pjwiue\" data-start=\"1017\" data-end=\"1069\"\u003eDurable construction for industrial environments\u003c\/li\u003e\n\u003cli data-section-id=\"wtda5t\" data-start=\"1070\" data-end=\"1109\"\u003eDirect replacement for Clemco 12191\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1111\" data-end=\"1114\"\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1116\" data-end=\"1144\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1145\" data-end=\"1418\"\u003e\n\u003cli data-section-id=\"18mny9n\" data-start=\"1145\" data-end=\"1169\"\u003e\n\u003cstrong data-start=\"1147\" data-end=\"1157\"\u003eModel:\u003c\/strong\u003e 1569-4400\u003c\/li\u003e\n\u003cli data-section-id=\"106zfp0\" data-start=\"1170\" data-end=\"1220\"\u003e\n\u003cstrong data-start=\"1172\" data-end=\"1181\"\u003eType:\u003c\/strong\u003e Air Solenoid Valve (Normally Closed)\u003c\/li\u003e\n\u003cli data-section-id=\"6gv93n\" data-start=\"1221\" data-end=\"1242\"\u003e\n\u003cstrong data-start=\"1223\" data-end=\"1235\"\u003eVoltage:\u003c\/strong\u003e 115V\u003c\/li\u003e\n\u003cli data-section-id=\"14u7p39\" data-start=\"1243\" data-end=\"1276\"\u003e\n\u003cstrong data-start=\"1245\" data-end=\"1265\"\u003eConnection Size:\u003c\/strong\u003e 1\/2\" NPT\u003c\/li\u003e\n\u003cli data-section-id=\"14tbemr\" data-start=\"1277\" data-end=\"1311\"\u003e\n\u003cstrong data-start=\"1279\" data-end=\"1293\"\u003eOperation:\u003c\/strong\u003e Normally Closed\u003c\/li\u003e\n\u003cli data-section-id=\"sjm4ho\" data-start=\"1312\" data-end=\"1370\"\u003e\n\u003cstrong data-start=\"1314\" data-end=\"1330\"\u003eApplication:\u003c\/strong\u003e Abrasive Blasting \/ Pneumatic Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1bfaixh\" data-start=\"1371\" data-end=\"1395\"\u003e\n\u003cstrong data-start=\"1373\" data-end=\"1384\"\u003eWeight:\u003c\/strong\u003e 1.50 lbs\u003c\/li\u003e\n\u003cli data-section-id=\"q0lk1p\" data-start=\"1396\" data-end=\"1418\"\u003e\n\u003cstrong data-start=\"1398\" data-end=\"1412\"\u003eCondition:\u003c\/strong\u003e New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1420\" data-end=\"1423\"\u003e\n\u003ch3 data-section-id=\"1tk5fu7\" data-start=\"1425\" data-end=\"1446\"\u003eOEM Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"1447\" data-end=\"1521\"\u003e\n\u003cli data-section-id=\"7tyl77\" data-start=\"1447\" data-end=\"1521\"\u003e\n\u003cstrong data-start=\"1449\" data-end=\"1505\"\u003eClemco Industries \/ Aerolyte Systems \/ Zero Products\u003c\/strong\u003e – Part #12191\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1523\" data-end=\"1526\"\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"1528\" data-end=\"1552\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"1553\" data-end=\"1760\"\u003e\n\u003cli data-section-id=\"5q98do\" data-start=\"1553\" data-end=\"1592\"\u003eAutomated blast pot control systems\u003c\/li\u003e\n\u003cli data-section-id=\"u2c90p\" data-start=\"1593\" data-end=\"1627\"\u003ePneumatic air control circuits\u003c\/li\u003e\n\u003cli data-section-id=\"18cp3bn\" data-start=\"1628\" data-end=\"1673\"\u003eDust collector and cabinet control setups\u003c\/li\u003e\n\u003cli data-section-id=\"5xmd5h\" data-start=\"1674\" data-end=\"1709\"\u003eRemote control blasting systems\u003c\/li\u003e\n\u003cli data-section-id=\"1adsulh\" data-start=\"1710\" data-end=\"1760\"\u003eReplacement for faulty or worn solenoid valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1762\" data-end=\"1765\"\u003e\n\u003ch3 data-section-id=\"oxb6nu\" data-start=\"1767\" data-end=\"1791\"\u003ePerformance Benefits\u003c\/h3\u003e\n\u003cul data-start=\"1792\" data-end=\"2031\"\u003e\n\u003cli data-section-id=\"x61u43\" data-start=\"1792\" data-end=\"1856\"\u003eEnables precise \u003cstrong data-start=\"1810\" data-end=\"1854\"\u003eon\/off air control via electrical signal\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dwh8gg\" data-start=\"1857\" data-end=\"1904\"\u003eImproves safety with \u003cstrong data-start=\"1880\" data-end=\"1902\"\u003efail-closed design\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"empfcc\" data-start=\"1905\" data-end=\"1947\"\u003eSupports automated blasting operations\u003c\/li\u003e\n\u003cli data-section-id=\"1hil10k\" data-start=\"1948\" data-end=\"1979\"\u003eReduces manual intervention\u003c\/li\u003e\n\u003cli data-section-id=\"11gsv7h\" data-start=\"1980\" data-end=\"2031\"\u003eEnsures consistent and reliable airflow control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2033\" data-end=\"2036\"\u003e\n\u003ch3 data-section-id=\"5031p5\" data-start=\"2038\" data-end=\"2060\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul data-start=\"2061\" data-end=\"2327\"\u003e\n\u003cli data-section-id=\"8js9by\" data-start=\"2061\" data-end=\"2107\"\u003eVerify \u003cstrong data-start=\"2070\" data-end=\"2105\"\u003e115V power supply compatibility\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"epuhct\" data-start=\"2108\" data-end=\"2172\"\u003eUse \u003cstrong data-start=\"2114\" data-end=\"2145\"\u003ePTFE tape or thread sealant\u003c\/strong\u003e for airtight connections\u003c\/li\u003e\n\u003cli data-section-id=\"p48vby\" data-start=\"2173\" data-end=\"2230\"\u003eEnsure proper wiring according to system requirements\u003c\/li\u003e\n\u003cli data-section-id=\"16z7vpj\" data-start=\"2231\" data-end=\"2283\"\u003eInstall in correct airflow direction (if marked)\u003c\/li\u003e\n\u003cli data-section-id=\"li1yjf\" data-start=\"2284\" data-end=\"2327\"\u003eTest valve operation after installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2329\" data-end=\"2332\"\u003e\n\u003ch3 data-section-id=\"1621uq5\" data-start=\"2334\" data-end=\"2359\"\u003eCompatibility \u0026amp; Notes\u003c\/h3\u003e\n\u003cul data-start=\"2360\" data-end=\"2594\"\u003e\n\u003cli data-section-id=\"1w9hrhz\" data-start=\"2360\" data-end=\"2428\"\u003eDesigned for \u003cstrong data-start=\"2375\" data-end=\"2426\"\u003eabrasive blasting and pneumatic control systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13fhie3\" data-start=\"2429\" data-end=\"2474\"\u003eWorks with standard \u003cstrong data-start=\"2451\" data-end=\"2472\"\u003e1\/2\" NPT fittings\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tkvowj\" data-start=\"2475\" data-end=\"2529\"\u003eNormally closed design enhances operational safety\u003c\/li\u003e\n\u003cli data-section-id=\"h63rai\" data-start=\"2530\" data-end=\"2594\"\u003eReplace malfunctioning valves to maintain system reliability\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pirate Brand","offers":[{"title":"Default Title","offer_id":53117587751275,"sku":"1569-4400","price":430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/COMETVALVE115__84430.jpg?v=1776613196","url":"https:\/\/generalsprayers.com\/products\/115v-air-solenoid-valve-1-2-npt-normally-closed-pneumatic-control-valve-replaces-clemco-12191","provider":"GeneralSprayers","version":"1.0","type":"link"}