{"product_id":"1-1-2-air-filter-40-micron-industrial-pneumatic-filter-mb-sg-md-replaces-schmidt-axxiom-2302-208-50","title":"1-1\/2\" Air Filter 40 Micron – Industrial Pneumatic Filter MB\/SG\/MD – Replaces Schmidt Axxiom 2302-208-50","description":"\u003cp data-start=\"0\" data-end=\"190\"\u003e\u003cstrong data-start=\"0\" data-end=\"10\"\u003eModel:\u003c\/strong\u003e 888-2302-20850PB\u003cbr data-start=\"27\" data-end=\"30\"\u003e\u003cstrong data-start=\"30\" data-end=\"43\"\u003eCategory:\u003c\/strong\u003e Air Control Components → Air Filters → Inline Pneumatic Filters\u003cbr data-start=\"107\" data-end=\"110\"\u003e\u003cstrong data-start=\"110\" data-end=\"119\"\u003eType:\u003c\/strong\u003e 1-1\/2\" Air Filter 40 Micron – Industrial Pneumatic Filter (MB\/SG\/MD)\u003c\/p\u003e\n\u003chr data-start=\"192\" data-end=\"195\"\u003e\n\u003cp data-start=\"197\" data-end=\"413\"\u003eThe \u003cstrong data-start=\"201\" data-end=\"232\"\u003e1-1\/2\" Air Filter 40 Micron\u003c\/strong\u003e is a high-capacity, heavy-duty pneumatic filter designed to \u003cstrong data-start=\"293\" data-end=\"351\"\u003eremove coarse contaminants from compressed air systems\u003c\/strong\u003e in large-scale abrasive blasting and industrial applications.\u003c\/p\u003e\n\u003chr data-start=\"1126\" data-end=\"1129\"\u003e\n\u003ch3 data-section-id=\"1v7iqwk\" data-start=\"1131\" data-end=\"1160\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"1161\" data-end=\"1524\"\u003e\n\u003cli data-section-id=\"wolklc\" data-start=\"1161\" data-end=\"1234\"\u003e\n\u003cstrong data-start=\"1163\" data-end=\"1187\"\u003e40-micron filtration\u003c\/strong\u003e for effective removal of coarse contaminants\u003c\/li\u003e\n\u003cli data-section-id=\"i9fd3\" data-start=\"1235\" data-end=\"1300\"\u003e\n\u003cstrong data-start=\"1237\" data-end=\"1258\"\u003e1-1\/2\" connection\u003c\/strong\u003e supports very high airflow applications\u003c\/li\u003e\n\u003cli data-section-id=\"gpygfg\" data-start=\"1301\" data-end=\"1351\"\u003eDesigned for \u003cstrong data-start=\"1316\" data-end=\"1349\"\u003eMB \/ SG \/ MD blasting systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rr5f12\" data-start=\"1352\" data-end=\"1413\"\u003eProtects \u003cstrong data-start=\"1363\" data-end=\"1411\"\u003eregulators, valves, and downstream equipment\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2nlup4\" data-start=\"1414\" data-end=\"1471\"\u003eReduces \u003cstrong data-start=\"1424\" data-end=\"1469\"\u003eclogging, wear, and maintenance frequency\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"687ova\" data-start=\"1472\" data-end=\"1524\"\u003eBuilt for \u003cstrong data-start=\"1484\" data-end=\"1522\"\u003eheavy-duty industrial environments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1526\" data-end=\"1529\"\u003e\n\u003ch3 data-section-id=\"12xlpaz\" data-start=\"1531\" data-end=\"1561\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1562\" data-end=\"1859\"\u003e\n\u003cli data-section-id=\"1s70yy3\" data-start=\"1562\" data-end=\"1593\"\u003e\n\u003cstrong data-start=\"1564\" data-end=\"1574\"\u003eModel:\u003c\/strong\u003e 888-2302-20850PB\u003c\/li\u003e\n\u003cli data-section-id=\"1jec2b\" data-start=\"1594\" data-end=\"1625\"\u003e\n\u003cstrong data-start=\"1596\" data-end=\"1616\"\u003eConnection Size:\u003c\/strong\u003e 1-1\/2\"\u003c\/li\u003e\n\u003cli data-section-id=\"1nddz99\" data-start=\"1626\" data-end=\"1662\"\u003e\n\u003cstrong data-start=\"1628\" data-end=\"1650\"\u003eFiltration Rating:\u003c\/strong\u003e 40 Micron\u003c\/li\u003e\n\u003cli data-section-id=\"1fff3r9\" data-start=\"1663\" data-end=\"1704\"\u003e\n\u003cstrong data-start=\"1665\" data-end=\"1674\"\u003eType:\u003c\/strong\u003e Inline Pneumatic Air Filter\u003c\/li\u003e\n\u003cli data-section-id=\"bbq1yj\" data-start=\"1705\" data-end=\"1747\"\u003e\n\u003cstrong data-start=\"1707\" data-end=\"1732\"\u003eSystem Compatibility:\u003c\/strong\u003e MB \/ SG \/ MD\u003c\/li\u003e\n\u003cli data-section-id=\"1jk0ehh\" data-start=\"1748\" data-end=\"1772\"\u003e\n\u003cstrong data-start=\"1750\" data-end=\"1761\"\u003eWeight:\u003c\/strong\u003e 5.10 lbs\u003c\/li\u003e\n\u003cli data-section-id=\"vicbml\" data-start=\"1773\" data-end=\"1836\"\u003e\n\u003cstrong data-start=\"1775\" data-end=\"1791\"\u003eApplication:\u003c\/strong\u003e Industrial Air Systems \/ Abrasive Blasting\u003c\/li\u003e\n\u003cli data-section-id=\"q0lk1p\" data-start=\"1837\" data-end=\"1859\"\u003e\n\u003cstrong data-start=\"1839\" data-end=\"1853\"\u003eCondition:\u003c\/strong\u003e New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1861\" data-end=\"1864\"\u003e\n\u003ch3 data-section-id=\"x963at\" data-start=\"1866\" data-end=\"1892\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"1893\" data-end=\"2075\"\u003e\n\u003cli data-section-id=\"agt6fc\" data-start=\"1893\" data-end=\"1931\"\u003eHigh-volume compressed air systems\u003c\/li\u003e\n\u003cli data-section-id=\"1c9jcja\" data-start=\"1932\" data-end=\"1987\"\u003eLarge abrasive blasting setups (MB \/ SG \/ MD units)\u003c\/li\u003e\n\u003cli data-section-id=\"1mtaw3f\" data-start=\"1988\" data-end=\"2019\"\u003eIndustrial air supply lines\u003c\/li\u003e\n\u003cli data-section-id=\"19u1gdi\" data-start=\"2020\" data-end=\"2075\"\u003ePre-filtration before regulators and control valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2077\" data-end=\"2080\"\u003e\n\u003ch3 data-section-id=\"9ubjlm\" data-start=\"2082\" data-end=\"2108\"\u003ePerformance Benefits\u003c\/h3\u003e\n\u003cul data-start=\"2109\" data-end=\"2345\"\u003e\n\u003cli data-section-id=\"2g5tib\" data-start=\"2109\" data-end=\"2172\"\u003eHandles \u003cstrong data-start=\"2119\" data-end=\"2170\"\u003emaximum airflow demand with minimal restriction\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bykic5\" data-start=\"2173\" data-end=\"2245\"\u003eRemoves \u003cstrong data-start=\"2183\" data-end=\"2243\"\u003ecoarse contaminants before reaching sensitive components\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hxi8js\" data-start=\"2246\" data-end=\"2296\"\u003eImproves \u003cstrong data-start=\"2257\" data-end=\"2294\"\u003esystem reliability and efficiency\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dim7iy\" data-start=\"2297\" data-end=\"2345\"\u003eExtends \u003cstrong data-start=\"2307\" data-end=\"2343\"\u003elifespan of downstream equipment\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2347\" data-end=\"2350\"\u003e\n\u003ch3 data-section-id=\"1k5j3rh\" data-start=\"2352\" data-end=\"2379\"\u003eCompatibility \u0026amp; Notes\u003c\/h3\u003e\n\u003cul data-start=\"2380\" data-end=\"2560\"\u003e\n\u003cli data-section-id=\"o82swq\" data-start=\"2380\" data-end=\"2437\"\u003eDirect replacement for \u003cstrong data-start=\"2405\" data-end=\"2435\"\u003eSchmidt Axxiom 2302-208-50\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ejmo27\" data-start=\"2438\" data-end=\"2495\"\u003eCompatible with \u003cstrong data-start=\"2456\" data-end=\"2493\"\u003estandard 1-1\/2\" pneumatic systems\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"bfiw6m\" data-start=\"2496\" data-end=\"2560\"\u003eIdeal as a \u003cstrong data-start=\"2509\" data-end=\"2537\"\u003eprimary filtration stage\u003c\/strong\u003e in high-flow systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pirate Brand","offers":[{"title":"Default Title","offer_id":53072326328683,"sku":"888-2302-20850PB","price":470.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/EMP517_271__75614.jpg?v=1775617719","url":"https:\/\/generalsprayers.com\/products\/1-1-2-air-filter-40-micron-industrial-pneumatic-filter-mb-sg-md-replaces-schmidt-axxiom-2302-208-50","provider":"GeneralSprayers","version":"1.0","type":"link"}