{"title":"Ignitors","description":"","products":[{"product_id":"51838u-120v-electric-ignitor-oem-replacement-part","title":"51838U 120V Electric Ignitor – OEM Replacement Part","description":"\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51838U\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Burner Components → Ignitors \u0026amp; Ignition Transformers\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e 51838U 120V Electric Ignitor\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003e51838U 120V Electric Ignitor (Part #5054)\u003c\/strong\u003e is a versatile, high-performance electronic ignition transformer designed for oil burner systems used in hot water pressure washers, heating equipment, and industrial combustion applications. Engineered to provide reliable ignition performance, this ignitor generates a powerful high-voltage spark that ensures fast and efficient burner startup.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cem\u003eImage shown for illustrative purposes only\u003c\/em\u003e\u003cb id=\"docs-internal-guid-e485561d-7fff-530e-ffe2-c17501402067\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOEM replacement 120V electric ignitor\u003c\/li\u003e\n\u003cli\u003ePowerful 20kV peak ignition output\u003c\/li\u003e\n\u003cli\u003eDelivers fast and efficient burner ignition\u003c\/li\u003e\n\u003cli\u003eCompatible with multiple burner platforms\u003c\/li\u003e\n\u003cli\u003eUniversal base plate adaptability\u003c\/li\u003e\n\u003cli\u003eFits many competitor transformer base plates\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight design\u003c\/li\u003e\n\u003cli\u003eVacuum-encapsulated synthetic resin construction\u003c\/li\u003e\n\u003cli\u003eExcellent moisture resistance\u003c\/li\u003e\n\u003cli\u003eSuperior electrical insulation properties\u003c\/li\u003e\n\u003cli\u003eHigh-temperature thermoplastic housing\u003c\/li\u003e\n\u003cli\u003eImpact-resistant and scratch-resistant construction\u003c\/li\u003e\n\u003cli\u003eChemical-resistant housing design\u003c\/li\u003e\n\u003cli\u003eUL recognized in the United States and Canada\u003c\/li\u003e\n\u003cli\u003eIntegrated wire routing and protection features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5054\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 51838U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electronic Burner Ignitor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 1.1 lbs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 VAC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 35 VA\u003c\/p\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 6kV RMS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak Voltage:\u003c\/strong\u003e 20kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 35mA RMS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary:\u003c\/strong\u003e Mid-Point Ground\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003ch3\u003eOperating Temperature\u003c\/h3\u003e\n\u003cp\u003e-20°F to 150°F\u003c\/p\u003e\n\u003ch3\u003eStorage Temperature\u003c\/h3\u003e\n\u003cp\u003e-40°F to 150°F\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Burner Systems\u003c\/h2\u003e\n\u003cp\u003eDesigned to adapt to:\u003c\/p\u003e\n\u003ch3\u003eBeckett\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA\u003c\/li\u003e\n\u003cli\u003eAF\u003c\/li\u003e\n\u003cli\u003eAFG\u003c\/li\u003e\n\u003cli\u003eS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAero\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVarious compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCarlin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e100\u003c\/li\u003e\n\u003cli\u003e101CRD\u003c\/li\u003e\n\u003cli\u003e102CRD\u003c\/li\u003e\n\u003cli\u003e200\u003c\/li\u003e\n\u003cli\u003e201\u003c\/li\u003e\n\u003cli\u003e500CRD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWayne\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eM\u003c\/li\u003e\n\u003cli\u003eE\u003c\/li\u003e\n\u003cli\u003eHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWeil-McLain\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVarious compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe versatile design also fits many other manufacturer transformer base plates.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Applications\u003c\/h2\u003e\n\u003cp\u003eCommonly used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHot water pressure washer burners\u003c\/li\u003e\n\u003cli\u003eFuel oil burner systems\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial burner assemblies\u003c\/li\u003e\n\u003cli\u003eMobile wash rigs\u003c\/li\u003e\n\u003cli\u003eFleet washing equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial cleaning systems\u003c\/li\u003e\n\u003cli\u003eCommercial maintenance equipment\u003c\/li\u003e\n\u003cli\u003eBurner service and repair applications\u003c\/li\u003e\n\u003cli\u003eFuel-fired heating equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Signs of Ignitor Failure\u003c\/h2\u003e\n\u003cp\u003eA replacement ignitor may be needed if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurner fails to ignite\u003c\/li\u003e\n\u003cli\u003eWeak ignition spark\u003c\/li\u003e\n\u003cli\u003eDelayed startup\u003c\/li\u003e\n\u003cli\u003eFrequent ignition lockouts\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eDamaged ignitor housing\u003c\/li\u003e\n\u003cli\u003eExcessive ignition noise\u003c\/li\u003e\n\u003cli\u003eNo spark output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-output ignition promotes reliable burner startup\u003c\/li\u003e\n\u003cli\u003eUniversal compatibility reduces inventory requirements\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant design improves reliability\u003c\/li\u003e\n\u003cli\u003eExcellent thermal management characteristics\u003c\/li\u003e\n\u003cli\u003eDurable housing withstands harsh environments\u003c\/li\u003e\n\u003cli\u003eHelps reduce burner downtime\u003c\/li\u003e\n\u003cli\u003eSupports efficient combustion system performance\u003c\/li\u003e\n\u003cli\u003eSuitable for demanding commercial applications\u003c\/li\u003e\n\u003cli\u003eLong service life under heavy-duty operating conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Instructions\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power to the burner system.\u003c\/li\u003e\n\u003cli\u003eAllow all burner components to cool completely.\u003c\/li\u003e\n\u003cli\u003eRemove the existing ignitor assembly.\u003c\/li\u003e\n\u003cli\u003eInspect wiring and ignition components.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement 51838U ignitor onto the appropriate base plate.\u003c\/li\u003e\n\u003cli\u003eRoute wires through the integrated breakout sections as needed.\u003c\/li\u003e\n\u003cli\u003eSecure all electrical connections.\u003c\/li\u003e\n\u003cli\u003eRestore power and test burner operation.\u003c\/li\u003e\n\u003cli\u003eVerify proper ignition and burner startup performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Always follow burner manufacturer installation procedures and wiring specifications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInspect ignition components during routine burner maintenance.\u003c\/li\u003e\n\u003cli\u003eVerify secure wiring connections.\u003c\/li\u003e\n\u003cli\u003eCheck ignition electrodes for proper condition and gap settings.\u003c\/li\u003e\n\u003cli\u003eKeep burner compartments clean and dry.\u003c\/li\u003e\n\u003cli\u003eInspect the ignitor housing for signs of damage.\u003c\/li\u003e\n\u003cli\u003eReplace ignition components showing signs of wear or failure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beckett","offers":[{"title":"Default Title","offer_id":53405280469355,"sku":null,"price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/51838UIgnitor_40ef2835-5035-47be-96e8-8791709d5532.jpg?v=1781740317"},{"product_id":"5250002u-beckett-s-model-240v-ignitor-oem-replacement-part","title":"5250002U Beckett S Model 240V Ignitor – OEM Replacement Part","description":"\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\" dir=\"auto\"\u003e\u003c\/section\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5250002U\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Burner Components → Ignitors \u0026amp; Ignition Transformers\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e 5250002U Beckett S Model 240V Ignitor\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003e5250002U Beckett S Model 240V Ignitor \u003c\/strong\u003eis a high-performance electronic ignition transformer engineered for \u003cstrong\u003e240-volt oil burner systems\u003c\/strong\u003e used in hot water pressure washers, industrial heating equipment, and commercial combustion applications. Designed to provide dependable ignition performance, this ignitor delivers a powerful high-voltage spark to ensure fast, reliable burner startup and efficient combustion.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cem\u003eImage shown for illustrative purposes only\u003c\/em\u003e\u003cb id=\"docs-internal-guid-6bb78327-7fff-b1d6-fdda-3f32d27355ad\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Beckett electronic oil ignitor\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for 240 VAC burner systems\u003c\/li\u003e\n\u003cli\u003ePowerful 19kV peak ignition output\u003c\/li\u003e\n\u003cli\u003eProvides fast and reliable burner ignition\u003c\/li\u003e\n\u003cli\u003eCompatible with Beckett SM, SF, CF500, and CF800 burners\u003c\/li\u003e\n\u003cli\u003eElectronic ignition design\u003c\/li\u003e\n\u003cli\u003eFloating secondary ground configuration\u003c\/li\u003e\n\u003cli\u003eCompact and durable construction\u003c\/li\u003e\n\u003cli\u003eOperates in demanding commercial environments\u003c\/li\u003e\n\u003cli\u003eExcellent temperature and humidity tolerance\u003c\/li\u003e\n\u003cli\u003eDirect replacement for multiple Beckett ignitor models\u003c\/li\u003e\n\u003cli\u003eHelps reduce burner startup failures and downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 6411\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 5250002U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Beckett\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electronic Oil Ignitor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 168–264 VAC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e 0.3 Amps\u003c\/p\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 19kV Peak\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 25mA RMS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Ground:\u003c\/strong\u003e Floating Ground\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003ch3\u003eOperating Temperature\u003c\/h3\u003e\n\u003cp\u003e-40°F to +150°F\u003c\/p\u003e\n\u003ch3\u003eStorage Temperature\u003c\/h3\u003e\n\u003cp\u003e-40°F to +150°F\u003c\/p\u003e\n\u003ch3\u003eHumidity\u003c\/h3\u003e\n\u003cp\u003e5% to 95% Relative Humidity\u003c\/p\u003e\n\u003cp\u003eCondensing\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Burner Systems\u003c\/h2\u003e\n\u003cp\u003eDesigned for use with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBeckett SM Burners\u003c\/li\u003e\n\u003cli\u003eBeckett SF Burners\u003c\/li\u003e\n\u003cli\u003eBeckett CF500 Burners\u003c\/li\u003e\n\u003cli\u003eBeckett CF800 Burners\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eReplaces\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBeckett 21176U\u003c\/li\u003e\n\u003cli\u003eBeckett 5199702U\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Applications\u003c\/h2\u003e\n\u003cp\u003eCommonly used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHot water pressure washer burners\u003c\/li\u003e\n\u003cli\u003eCommercial oil-fired burner systems\u003c\/li\u003e\n\u003cli\u003eIndustrial heating equipment\u003c\/li\u003e\n\u003cli\u003eFuel oil combustion systems\u003c\/li\u003e\n\u003cli\u003eIndustrial cleaning equipment\u003c\/li\u003e\n\u003cli\u003eFleet washing systems\u003c\/li\u003e\n\u003cli\u003eMobile wash rigs\u003c\/li\u003e\n\u003cli\u003eCommercial wash equipment\u003c\/li\u003e\n\u003cli\u003eBurner repair and maintenance applications\u003c\/li\u003e\n\u003cli\u003eIndustrial burner assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Signs of Ignitor Failure\u003c\/h2\u003e\n\u003cp\u003eA replacement ignitor may be required if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurner fails to ignite\u003c\/li\u003e\n\u003cli\u003eWeak ignition spark\u003c\/li\u003e\n\u003cli\u003eDelayed burner startup\u003c\/li\u003e\n\u003cli\u003eFrequent ignition lockouts\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eNo spark output during startup\u003c\/li\u003e\n\u003cli\u003eExcessive ignition-related service calls\u003c\/li\u003e\n\u003cli\u003eDamaged ignitor housing or wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers powerful 19kV ignition output\u003c\/li\u003e\n\u003cli\u003eSupports fast burner startup\u003c\/li\u003e\n\u003cli\u003eImproves ignition reliability\u003c\/li\u003e\n\u003cli\u003eHelps reduce burner downtime\u003c\/li\u003e\n\u003cli\u003eDesigned for demanding commercial applications\u003c\/li\u003e\n\u003cli\u003eOperates across a wide voltage range\u003c\/li\u003e\n\u003cli\u003eDurable electronic construction\u003c\/li\u003e\n\u003cli\u003eExcellent resistance to temperature extremes\u003c\/li\u003e\n\u003cli\u003eCompatible with several Beckett burner platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Instructions\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power to the burner system.\u003c\/li\u003e\n\u003cli\u003eVerify the burner utilizes a 240 VAC ignition system.\u003c\/li\u003e\n\u003cli\u003eAllow all burner components to cool completely.\u003c\/li\u003e\n\u003cli\u003eRemove the existing ignitor assembly.\u003c\/li\u003e\n\u003cli\u003eInspect ignition wiring and burner components.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement 5250002U ignitor.\u003c\/li\u003e\n\u003cli\u003eSecure all electrical connections according to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003eRestore power and test burner startup.\u003c\/li\u003e\n\u003cli\u003eVerify proper ignition and burner operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Confirm voltage compatibility before installation. This ignitor is intended for 240 VAC systems only.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInspect ignition components during routine burner service.\u003c\/li\u003e\n\u003cli\u003eVerify wiring connections remain secure.\u003c\/li\u003e\n\u003cli\u003eCheck ignition electrodes for proper gap and condition.\u003c\/li\u003e\n\u003cli\u003eInspect ignitor housing for physical damage.\u003c\/li\u003e\n\u003cli\u003eKeep burner compartments clean and dry.\u003c\/li\u003e\n\u003cli\u003eReplace worn ignition components promptly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Beckett","offers":[{"title":"Default Title","offer_id":53405284139371,"sku":null,"price":135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/5250002U.jpg?v=1781740590"},{"product_id":"5250001u-beckett-a-model-240v-ignitor-oem-replacement-part","title":"5250001U Beckett A Model 240V Ignitor – OEM Replacement Part","description":"\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\" dir=\"auto\"\u003e\u003c\/section\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5250001U\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Burner Components → Ignitors \u0026amp; Ignition Transformers\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Beckett A Model 240V Ignitor\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003eBeckett 5250001U A Model 240V Ignitor\u003c\/strong\u003e is a high-performance electronic ignition assembly designed for \u003cstrong\u003e240-volt oil burner systems\u003c\/strong\u003e used in hot water pressure washers, industrial heating equipment, and commercial combustion applications. Engineered to provide fast, dependable burner ignition, this ignitor delivers a powerful \u003cstrong\u003e20,000-volt peak output\u003c\/strong\u003e to ensure efficient startup and reliable burner operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Beckett electronic ignitor assembly\u003c\/li\u003e\n\u003cli\u003eDesigned for 240 VAC burner systems\u003c\/li\u003e\n\u003cli\u003ePowerful 20,000-volt peak ignition output\u003c\/li\u003e\n\u003cli\u003eProvides fast and reliable burner startup\u003c\/li\u003e\n\u003cli\u003eCompatible with Beckett A, AF, AFG, and NX Series burners\u003c\/li\u003e\n\u003cli\u003eDirect replacement for multiple Beckett ignitor models\u003c\/li\u003e\n\u003cli\u003eElectronic ignition technology\u003c\/li\u003e\n\u003cli\u003eDurable construction for commercial applications\u003c\/li\u003e\n\u003cli\u003eHelps improve burner reliability\u003c\/li\u003e\n\u003cli\u003eReduces ignition-related downtime\u003c\/li\u003e\n\u003cli\u003eDesigned for demanding industrial environments\u003c\/li\u003e\n\u003cli\u003eEasy replacement installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5250001U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Beckett\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electronic Burner Ignitor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 240 VAC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak Output Voltage:\u003c\/strong\u003e 20,000 Volts\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eReplaces\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBeckett 5199701U\u003c\/li\u003e\n\u003cli\u003eBeckett 51993U\u003c\/li\u003e\n\u003cli\u003eBeckett 5929U\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Burner Systems\u003c\/h2\u003e\n\u003cp\u003eDesigned for use with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBeckett A Series Burners\u003c\/li\u003e\n\u003cli\u003eBeckett AF Series Burners\u003c\/li\u003e\n\u003cli\u003eBeckett AFG Series Burners\u003c\/li\u003e\n\u003cli\u003eBeckett NX Series Burners\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Applications\u003c\/h2\u003e\n\u003cp\u003eCommonly used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHot water pressure washer burners\u003c\/li\u003e\n\u003cli\u003eCommercial oil-fired burner systems\u003c\/li\u003e\n\u003cli\u003eIndustrial heating equipment\u003c\/li\u003e\n\u003cli\u003eFuel oil combustion systems\u003c\/li\u003e\n\u003cli\u003eMobile wash rigs\u003c\/li\u003e\n\u003cli\u003eFleet washing equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial cleaning equipment\u003c\/li\u003e\n\u003cli\u003eCommercial maintenance equipment\u003c\/li\u003e\n\u003cli\u003eBurner repair applications\u003c\/li\u003e\n\u003cli\u003eIndustrial burner assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Signs of Ignitor Failure\u003c\/h2\u003e\n\u003cp\u003eA replacement ignitor may be needed if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurner fails to ignite\u003c\/li\u003e\n\u003cli\u003eDelayed burner startup\u003c\/li\u003e\n\u003cli\u003eWeak or inconsistent ignition spark\u003c\/li\u003e\n\u003cli\u003eFrequent burner lockouts\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eIgnition-related fault conditions\u003c\/li\u003e\n\u003cli\u003eNo spark during startup sequence\u003c\/li\u003e\n\u003cli\u003eDamaged ignitor housing or wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-voltage output promotes dependable ignition\u003c\/li\u003e\n\u003cli\u003eSupports fast burner startup\u003c\/li\u003e\n\u003cli\u003eHelps improve combustion efficiency\u003c\/li\u003e\n\u003cli\u003eReduces burner downtime\u003c\/li\u003e\n\u003cli\u003eDesigned for continuous commercial operation\u003c\/li\u003e\n\u003cli\u003eCompatible with multiple Beckett burner platforms\u003c\/li\u003e\n\u003cli\u003eReliable electronic ignition performance\u003c\/li\u003e\n\u003cli\u003eHelps extend burner system reliability\u003c\/li\u003e\n\u003cli\u003eSuitable for demanding industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Instructions\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power to the burner system.\u003c\/li\u003e\n\u003cli\u003eVerify the burner utilizes a compatible 240 VAC ignition system.\u003c\/li\u003e\n\u003cli\u003eAllow burner components to cool completely.\u003c\/li\u003e\n\u003cli\u003eRemove the existing ignitor assembly.\u003c\/li\u003e\n\u003cli\u003eInspect ignition wiring and burner components.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement Beckett 5250001U ignitor.\u003c\/li\u003e\n\u003cli\u003eSecure all wiring connections according to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003eRestore power and test burner operation.\u003c\/li\u003e\n\u003cli\u003eVerify proper ignition and burner startup performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This ignitor is designed for 240 VAC burner systems only. Verify voltage compatibility before installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInspect ignition components during routine burner service.\u003c\/li\u003e\n\u003cli\u003eVerify proper wiring connections.\u003c\/li\u003e\n\u003cli\u003eCheck ignition electrodes for wear and proper gap settings.\u003c\/li\u003e\n\u003cli\u003eInspect the ignitor housing for physical damage.\u003c\/li\u003e\n\u003cli\u003eKeep burner compartments clean and dry.\u003c\/li\u003e\n\u003cli\u003eReplace worn ignition components promptly to maintain reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Beckett","offers":[{"title":"Default Title","offer_id":53405285908843,"sku":null,"price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/5250001U.webp?v=1781740920"},{"product_id":"5270001u-beckett-a-powerlight-12vdc-ignitor-with-cad-cell-oem-replacement-part","title":"5270001U Beckett A PowerLight 12VDC Ignitor with Cad Cell – OEM Replacement Part","description":"\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5270001U\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Burner Components → Ignitors \u0026amp; Flame Detection Systems\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Beckett A PowerLight 12VDC Ignitor with Cad Cell\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003eBeckett 5270001U A PowerLight 12VDC Ignitor with Cad Cell\u003c\/strong\u003e is an advanced electronic ignition system designed for 12-volt oil burner applications used in hot water pressure washers, mobile wash systems, road stripers, asphalt equipment, and other commercial burner applications. Combining a high-performance electronic ignitor with an included cad cell flame sensor, this unit delivers reliable ignition, improved durability, and simplified installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Beckett PowerLight ignitor assembly\u003c\/li\u003e\n\u003cli\u003eIncludes cad cell flame sensor (not pre-installed)\u003c\/li\u003e\n\u003cli\u003eDesigned for 12VDC burner systems\u003c\/li\u003e\n\u003cli\u003ePowerful 20kV peak ignition output\u003c\/li\u003e\n\u003cli\u003eUniversal replacement design\u003c\/li\u003e\n\u003cli\u003eCompatible with Beckett and many other burner brands\u003c\/li\u003e\n\u003cli\u003eEliminates external heat sink design\u003c\/li\u003e\n\u003cli\u003eImproved resistance to overheating and arcing\u003c\/li\u003e\n\u003cli\u003eFully potted waterproof electronic construction\u003c\/li\u003e\n\u003cli\u003eEnhanced thermal shock protection\u003c\/li\u003e\n\u003cli\u003eSimplified wiring with fewer connections\u003c\/li\u003e\n\u003cli\u003eLightweight single-piece design\u003c\/li\u003e\n\u003cli\u003eSupports interrupted ignition conversion\u003c\/li\u003e\n\u003cli\u003eHelps increase ignitor service life\u003c\/li\u003e\n\u003cli\u003eReduces maintenance and replacement frequency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5270001U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Beckett\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e PowerLight\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electronic Ignitor with Cad Cell\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCad Cell Included:\u003c\/strong\u003e Yes (Not Installed)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 10.8–16 VDC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e 1.8 Amps\u003c\/p\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 20kV Peak\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 25mA RMS\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003ch3\u003eOperating Temperature\u003c\/h3\u003e\n\u003cp\u003e-40°F to 150°F\u003c\/p\u003e\n\u003ch3\u003eStorage Temperature\u003c\/h3\u003e\n\u003cp\u003e-40°F to 150°F\u003c\/p\u003e\n\u003ch3\u003eHumidity\u003c\/h3\u003e\n\u003cp\u003e5% to 95% Relative Humidity\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Applications\u003c\/h2\u003e\n\u003cp\u003eCommonly used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHot water pressure washer burners\u003c\/li\u003e\n\u003cli\u003eMobile wash rigs\u003c\/li\u003e\n\u003cli\u003eRoad striping equipment\u003c\/li\u003e\n\u003cli\u003eCrack sealing equipment\u003c\/li\u003e\n\u003cli\u003eAsphalt distributors\u003c\/li\u003e\n\u003cli\u003eHot patch equipment\u003c\/li\u003e\n\u003cli\u003eOil burner systems\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial burner applications\u003c\/li\u003e\n\u003cli\u003eMobile maintenance equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Signs of Ignitor Failure\u003c\/h2\u003e\n\u003cp\u003eA replacement ignitor may be needed if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurner fails to ignite\u003c\/li\u003e\n\u003cli\u003eDelayed burner startup\u003c\/li\u003e\n\u003cli\u003eWeak ignition spark\u003c\/li\u003e\n\u003cli\u003eFrequent burner lockouts\u003c\/li\u003e\n\u003cli\u003eIgnition-related fault codes\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eExcessive arcing\u003c\/li\u003e\n\u003cli\u003eDamaged or deteriorated ignitor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-voltage ignition improves burner startup reliability\u003c\/li\u003e\n\u003cli\u003eEliminates external heat sink failure points\u003c\/li\u003e\n\u003cli\u003eFully sealed design protects electronics from moisture\u003c\/li\u003e\n\u003cli\u003eImproved resistance to vibration and thermal shock\u003c\/li\u003e\n\u003cli\u003eSupports longer ignitor service life\u003c\/li\u003e\n\u003cli\u003eReduced wiring simplifies installation\u003c\/li\u003e\n\u003cli\u003eUniversal fitment reduces replacement inventory needs\u003c\/li\u003e\n\u003cli\u003eIncluded cad cell provides flame monitoring capability\u003c\/li\u003e\n\u003cli\u003eIdeal for demanding commercial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Instructions\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power from the burner system.\u003c\/li\u003e\n\u003cli\u003eAllow burner components to cool completely.\u003c\/li\u003e\n\u003cli\u003eRemove the existing ignitor assembly.\u003c\/li\u003e\n\u003cli\u003eInspect ignition wiring and burner components.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement PowerLight ignitor.\u003c\/li\u003e\n\u003cli\u003eInstall the included cad cell if required by the burner system.\u003c\/li\u003e\n\u003cli\u003eConnect wiring according to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003eVerify proper voltage compatibility.\u003c\/li\u003e\n\u003cli\u003eRestore power and test burner startup and flame detection functions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The included cad cell is supplied separately and must be installed according to burner manufacturer requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInspect ignition components during routine burner service.\u003c\/li\u003e\n\u003cli\u003eVerify cad cell cleanliness and proper positioning.\u003c\/li\u003e\n\u003cli\u003eCheck wiring connections regularly.\u003c\/li\u003e\n\u003cli\u003eInspect electrodes for proper gap and condition.\u003c\/li\u003e\n\u003cli\u003eKeep burner compartments clean and dry.\u003c\/li\u003e\n\u003cli\u003eReplace damaged ignition or flame-sensing components promptly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beckett","offers":[{"title":"Default Title","offer_id":53405303865707,"sku":"5270001U","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/5270001U.webp?v=1781741219"},{"product_id":"5270005u-beckett-12vdc-powerlight-ignitor-only-oem-replacement-part","title":"5270005U Beckett 12VDC PowerLight Ignitor Only – OEM Replacement Part","description":"\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\" dir=\"auto\"\u003e\u003c\/section\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5270005U\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Pressure Washer Parts → Burner Components → Ignitors\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Beckett 12VDC PowerLight Electronic Ignitor\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eThe \u003cstrong\u003eBeckett 5270005U 12VDC PowerLight Ignitor\u003c\/strong\u003e is a high-performance electronic ignition module designed for Beckett ADC burner applications and other compatible 12-volt burner systems. Utilizing advanced solid-state technology, this ignitor delivers dependable ignition performance while offering improved reliability, reduced maintenance requirements, and long service life in demanding commercial and industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Beckett OEM replacement ignitor\u003c\/li\u003e\n\u003cli\u003eDesigned for Beckett ADC burner applications\u003c\/li\u003e\n\u003cli\u003eOperates on 12VDC systems\u003c\/li\u003e\n\u003cli\u003ePowerful 14,000-volt spark output\u003c\/li\u003e\n\u003cli\u003eAdvanced solid-state ignition technology\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight design\u003c\/li\u003e\n\u003cli\u003eReliable burner startup performance\u003c\/li\u003e\n\u003cli\u003eDurable construction for demanding environments\u003c\/li\u003e\n\u003cli\u003eReduced maintenance compared to older ignition systems\u003c\/li\u003e\n\u003cli\u003eDirect replacement solution for compatible burners\u003c\/li\u003e\n\u003cli\u003eIdeal for mobile and commercial equipment\u003c\/li\u003e\n\u003cli\u003eIgnitor only configuration for flexible installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5270005U\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Beckett\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e PowerLight\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electronic Ignitor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Burner Type:\u003c\/strong\u003e ADC Burners\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpark Output:\u003c\/strong\u003e 14,000 Volts\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnology:\u003c\/strong\u003e Solid-State Electronic Ignition\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBaseplate Included:\u003c\/strong\u003e No\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHot water pressure washer burners\u003c\/li\u003e\n\u003cli\u003eMobile wash systems\u003c\/li\u003e\n\u003cli\u003eRoad striping equipment\u003c\/li\u003e\n\u003cli\u003eCrack sealing machines\u003c\/li\u003e\n\u003cli\u003eAsphalt maintenance equipment\u003c\/li\u003e\n\u003cli\u003eHot patchers\u003c\/li\u003e\n\u003cli\u003eIndustrial burner systems\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eFleet maintenance equipment\u003c\/li\u003e\n\u003cli\u003eMobile service units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Signs of Ignitor Failure\u003c\/h2\u003e\n\u003cp\u003eA replacement ignitor may be required if you notice:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurner fails to ignite\u003c\/li\u003e\n\u003cli\u003eWeak or inconsistent spark\u003c\/li\u003e\n\u003cli\u003eDelayed ignition\u003c\/li\u003e\n\u003cli\u003eFrequent burner lockouts\u003c\/li\u003e\n\u003cli\u003eIgnition-related fault conditions\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eVisible ignitor damage\u003c\/li\u003e\n\u003cli\u003eReduced burner performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePerformance Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSolid-state technology improves reliability\u003c\/li\u003e\n\u003cli\u003eProvides consistent ignition performance\u003c\/li\u003e\n\u003cli\u003eDelivers powerful 14kV spark output\u003c\/li\u003e\n\u003cli\u003eLightweight design simplifies installation\u003c\/li\u003e\n\u003cli\u003eSuitable for demanding commercial environments\u003c\/li\u003e\n\u003cli\u003eHelps reduce burner downtime\u003c\/li\u003e\n\u003cli\u003eLong service life under normal operating conditions\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for 12VDC burner systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing the burner.\u003c\/li\u003e\n\u003cli\u003eRemove the existing ignitor assembly.\u003c\/li\u003e\n\u003cli\u003eInspect wiring and ignition components for wear or damage.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement ignitor using existing compatible mounting hardware.\u003c\/li\u003e\n\u003cli\u003eConnect wiring according to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003eVerify proper voltage supply before operation.\u003c\/li\u003e\n\u003cli\u003eRestore power and test burner ignition performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This part includes the ignitor only and does not include a mounting baseplate.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance Recommendations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInspect ignition wiring regularly.\u003c\/li\u003e\n\u003cli\u003eKeep burner compartments clean and dry.\u003c\/li\u003e\n\u003cli\u003eCheck ignition components during routine service intervals.\u003c\/li\u003e\n\u003cli\u003eVerify secure electrical connections.\u003c\/li\u003e\n\u003cli\u003eReplace damaged or worn ignition components promptly.\u003c\/li\u003e\n\u003cli\u003eFollow burner manufacturer maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Beckett","offers":[{"title":"Default Title","offer_id":53405372055915,"sku":null,"price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/9201\/5723\/files\/5270005U.webp?v=1781742031"}],"url":"https:\/\/generalsprayers.com\/collections\/ignitors.oembed","provider":"GeneralSprayers","version":"1.0","type":"link"}